Fluke i2000 Flex AC Current Clamp

SKU
I2000 FLEX
Manufacturer:
Fluke
Fluke

Key Features:

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600 V safety rating
  • Product Options:
    Special Price $503.99 Regular Price $559.99

    Secured and trusted checkout with

                Very large, flexible AC current clamp

    Fluke Current clamps are the ideal tools to extend the current ranges of Fluke tools. The i2000 Flex is a flexible AC current probe for use with oscilloscopes and multimeters. The supplied Dual Banana to BNC Adapter can be used for connection to instruments with banana inputs. The i2000flex is optimized for current measurement on thick and hard to reach conductors.

    Electrical specifications
    Current ranges20 A
    200 A
    2000 A
    AC rms
    Output sensitivity (AC-coupled)1 mV
    10 mV
    100 mV
    1 mV per A
    Load impedance100 kΩ minimum
    Accuracyat +25°C
    ±1% of range (45 Hz to 65 Hz)
    Linearity10% to 100% of range
    ±0.2% of reading
    Noise8 mV AC rms (30 A)
    2 mV AC rms (300 A, 3000 A)
    Frequency range10 Hz to 20 kHz (-3 dB)
    Phase error< ±1° (45 Hz to 65 Hz)
    ±10° (at 20 kHz)
    Position sensitivitywith cable > 25 mm from the coupling
    ±2% of range
    External fieldwith cable > 200 mm from the head
    ±1% of range
    Power supply2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
    Temperature Coefficient±0.08% of reading per °C
    Working voltagesee Safety standards section
    600 V AC rms or DC
    General Specifications
    Head Circumference610 mm (24 in)
    Head cable diameter14.3 mm (0.56 in)
    Head bend radius38.1 mm (1.5 in)
    Cable length (head to electronics)2 m (6.56 ft)
    Output connectionMolded 4 mm safety plugs (not integrated)
    Operating temperature range0°C to +70°C (32°F to 158°F) (head and electronics)
    Storage temperature range-40°C to +105°C (-40°F to 221°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Operating humidity15% to 85% (non-condensing)
    Weight180 g (6.34 oz) (head)
    190 g (6.70 oz) (electronics)
    Safety standardsEN 61010-031: 2002
    EN 61010-2-032: 2002
    EN 61010-1: 2001
    600 Vrms, Category III, Pollution Degree 2
    Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
    EMC standardsEN 61326: 1998 +A1, A2, and A3
    Dimensions (H x W x D)116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)