Fluke 3000 FC DMM / PRV240 Proving Unit Kit

SKU
FLK-3000FC/PRV240
Manufacturer:
Fluke
Fluke

Key Features:

Fluke 3000 FC Wireless Multimeter

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

Fluke PRV240 Proving Unit

  • Sources both ac and dc steady-state voltage - supplies 240 V dc/ac
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Includes Magnetic Hanging Strap
  • Long battery life - 5,000 tests per set of four AA batteries
Special Price $476.99 Regular Price $529.99

Secured and trusted checkout with

The Fluke 3000 FC DMM / PRV240 Kit includes a Fluke 3000 FC Wireless Multimeter and a Fluke PRV240 Proving Unit.

Fluke 3000 FC Wireless Multimeter

AC Voltage
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy1.5% + 3
mA DC2Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 V DC
< 0.9 V DC
Typical short circuit current< 350 mA
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 V DC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions± 12 counts for changes > 350 mS in duration.
AC functions± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety complianceANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

 

Fluke PRV240 Proving Unit

Output voltage

240 V ac rms or dc

±10 % ≥1 MΩ

LoZ >3 kΩ load

60 V ac typical
50 V ac rms minimum

LED power indicator

Turns on when output voltage is present

Battery

4 x AA Alkaline batteries NEDA

24 A IEC LR03

Battery life

5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load

Operating temperature

-10 °C to +50 °C

Operating humidity

0 % to 90 % (0 °C to 35 °C)

0 % to 70 % (35 °C to 55 °C)

Operating altitude

2000 m

Dimensions

11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2

Weight

0.23 kg (8 oz) includes batteries

Safety

IEC61010-1, IEC61010-2-030

Certification

CSA-CUS, CE

Warranty

One Year

Electromagnetic Compatibility (EMC)

IEC 61326-1

Portable EM environment; CISPR 11, Group 1, Class A

US (FCC)

47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes

 

Includes:

Fluke 3000 FC Series Wireless Multimeter

  • • True-RMS Wireless Multimeter
  • • Three AA Alkaline batteries (installed)
  • • TL175 Test Leads
  • • AC175 Alligator Clips

Fluke PRV240 Proving Unit

  • • TPAK hanging strap
  • • Four AA batteries
  • • Instruction sheet
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account