Fluke Calibration 9009 Dry Block Calibrator

SKU
9009
Manufacturer:
Fluke Calibration
Fluke Calibration

Key Features:

  • Two wells in each block (Test 4 Sensors)
  • Rugged, lightweight, watertight enclosures
  • Calibrate HOT and COLD temperatures at the same time
  • Two independently controlled temperature blocks
  • Hot block temperature range from 50 to 350 C
  • Cold Block covers the range -15 to 110 C
  • Stability 0.05 C Well to well uniformity 0.1 C
  • Display resolution: 0.1 Degree
  • Stabilization times: 8 minutes
  • Well Depth: 4" (102mm)
  • Size: 7"H x 10.5"W x 9.75"D (178 x 267 x 248 mm)
  • Weight: 10lb (4.5 kg)
  • Includes NIST Traceable Calibration Certificate
  • Product Options:
    $8,483.00

    Secured and trusted checkout with

    Hart's new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. The hot block provides temperatures from 50 to 350 C, while the cold block covers the range -15 to 110 C. Each block is controlled by a precision Hart Scientific temperature controller. Each temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference thermometer, or you can use the two temperature wells to get quick “zero” and “span” references for transmitter calibrations. The 9009 is housed in a tough Pelican™ case that is both airtight and watertight, weighing only 10 pounds. Inserts are available to accommodate sensors of any size from 1/16" (1.6 mm) to 7/16” (11.1 mm).The 9009 also delivers the performance you expect from a Hart Scientific temperature source. The cold block is calibrated to within 0.2 C with stability of 0.05 C. The hot block's display is accurate to 0.6 C with stability of 0.05 C. Two blocks in one unit, a total range of -15 to 350 C, portability, durability, versatility, performance and automation.
     HOT BLOCKCOLD BLOCK
    Range:

    50 to 350 °C
    (122 °F to 662 °F)

    -15 to 110 °C
    (5 F to 230 °F)
    (-8 with hot block
    at 350 °C )

    Accuracy:

     +/- 0.6 °C

    +/- 0.2 °C

    Stability:

    +/- 0.05 °C

    +/- 0.05 °C

    Uniformity:

    +/- 0.1 °C

    +/- 0.1 °C

    Resolution:

    0.1

    0.1

    Heating Times:

    10 minutes from
    25 °C to 350 °C

    15 minutes from
    25 °C to 110 °C

    Cooling Times

    30 minutes from
    350 °C to 100 °C

    16 minutes from
    25 °C to -15 °C

    Stabilization:

    8 minutes

    8 minutes

    Well Depth:

    4" (102 mm)

    4" (102 mm)

    Inserts:Two 1/4” (6.4 mm) and 3/16” (4.8 mm) inserts included; Others Available
    PC Interface:RS-232 included with free Interface-it software
    Power:115 VAC (±10%), 3 A, or 230 VAC (±10%), 2 A, specify, 50/60 Hz, 250 W
    Size:7" H x 10.5" W x 9.75" D (178 x 267 x 248 mm)
    Weight:10 lb. (4.5 kg)
    Write Your Own Review
    Only registered users can write reviews. Please Sign in or create an account