Fluke Calibration 1524-P3 Mega-Kit

SKU
1524-P3-156
Manufacturer:
Fluke Calibration
Fluke Calibration

Key Features:

Fluke Calibration 1524 Two Channel Reference Thermometer

  • High accuracy
  • PRTs: up to ± 0.011 °C
  • Thermocouples: up to ± 0.24 °C
  • Precision thermistors: ± 0.002 °C
  • Smart connectors to load probe information automatically
  • A simple user interface to quickly see trends

 

Fluke Calibration 5627A Industrial Grade Precision RTD Probe

  • Vibration and shock resistant
  • NVLAP-accredited calibration included, lab code 200706-0

 

$5,060.00

Secured and trusted checkout with

The Fluke Calibration 1524-P3 Mega Kit includes a 1524 Reference Thermometer, 5627A PRT probe (–200 °C to 420 °C, 100 ohm (1/4 x 12 inch)), 2373-LTC Lemo to TC Adapter, TPAK, and a 1523/1524 carrying case.

Fluke Calibration 1524 Two Channel Reference Thermometer Specifications

Specifications
Input channels2
Logging15,000 time and date stamped; 25 readings with statistics
Sample interval
(normal)
1 second
Sample interval (fast mode)0.3 seconds (see technical manual for details)
Sensor typesPRTs, RTDs, thermistors, and thermocouples
Thermocouple typesC, E, J, K, L, M, N, T, U, B, R, S
Operating temperature-10°C to 60°C (Best accuracy 13°C to 33°C)
Power requirements3 AA alkaline batteries
Size96 x 200 x 47 mm
(3.75 x 7.9 x 1.86 in)
Weight0.65 kg (1.4 lb)
Environmental conditions for best accuracy13°C to 33°C
Millivolt range and accuracy–10 mV to 75 mV ±(0.005% + 5 μV)
Resistance range and accuracy0 Ω to 400 Ω ±(0.004% + 0.002 Ω)
200 Ω to 50 kΩ ±(0.01% + 0.5 Ω)
50 kΩ to 500 kΩ ± (0.03%)
Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C)±(0.001%/°C + 1 μV/°C)
Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C)0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω)
0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ)
0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ)
Excitation current, resistance1 mA (0 Ω to 400 Ω)
10 μA (0 Ω to 50 kΩ)
2 µA (50 kΩ to 500 kΩ)
Thermocouple Equivalent Temperature Accuracies (Readout Only)
Type B±0.85°C from 600°C to 800°C
±0.68°C from 800°C to 1000°C
±0.57°C from 1000°C to 1800°C
Type C±0.32°C from 100ºC to 550°C
±0.71°C from 550°C to 2300°C
Type E±0.52°C from -200°C to 0°C
±0.22°C from 0°C to 950°C
Type J±0.52°C from -200°C to 0°C
±0.23°C from 0°C to 1200°C
Type K±0.61°C from -200°C to 0°C
±0.24°C from 0°C to 1370°C
Type L±0.36°C from -200°C to 0°C
±0.23°C from 0°C to 1370°C
Type M±0.26°C from -20°C to 0°C
±0.25°C from 0°C to 400°C
±0.22°C from 400°C to 1400°C
Type N±0.72°C from -200°C to 0°C
±0.28°C from 0°C to 1300°C
Type R±1.09°C from -20°C to 0°C
±0.97°C from 0°C to 500°C
±0.49°C from 500°C to 1750°C
Type S±1.05°C from -20°C to 0°C
±0.95°C from 0°C to 500°C
±0.56°C from 500°C to 1750°C
Type T±0.60°C from -200°C to 0°C
±0.25°C from 0°C to 400°C
Type U±0.54°C from -200°C to 0°C
±0.24°C from 0°C to 400°C
Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction.
1524 Accuracies with Selected Probes (±°C)
-200°C5616-12: 0.014
5615-6: 0.025
5627A-12: 0.027
5610-9: n/a
0°C5616-12: 0.021
5615-6: 0.021
5627A-12: 0.049
5610-9: 0.009
100°C5616-12: 0.027
5615-6: 0.028
5627A-12: 0.065
5610-9: 0.009
300°C5616-12: 0.040
5615-6: 0.043
5627A-12: 0.103
5610-9: n/a
420°C5616-12: 0.050
5615-6: n/a
5627A-12: 0.130
5610-9: n/a
Includes readout accuracy, probe calibration, and probe drift
PRT Equivalent Temperature Accuracy (Readout only)
–100°C±0.011
0°C±0.015
100°C±0.019
200°C±0.023
400°C±0.031
600°C±0.039
Thermistor Equivalent Temperature Accuracy (Readout Only)
0°C±0.002
25°C±0.003
50°C±0.006
75°C±0.014
100°C±0.030

 

Fluke Calibration 5627A Industrial Grade Precision RTD Probe Specifications

ResistanceNominal 100 Ω
Temperature Coefficient0.00385 Ω/Ω/ °C nominal
Temperature Range−200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C)
Drift Rate (k=2)± 0.04 °C at 0 °C after 100 hours at 420 °C
Sheath Material316 Stainless Steel
LeadsPTFE-insulated, nickel-plated stranded copper, 22 AWG
TerminationSpecify. See Ordering Information.
Time ConstantFour seconds maximum for 63.2 % response to step change in water moving at 3 fps.
Bending RadiusSheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
CalibrationIncludes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9).
ITS-90 coefficients included.
ImmersionAt least 100 mm (4 in) recommended
Calibrated Accuracy† (k=2)± 0.026 °C at -196 °C
± 0.046 °C at 0 °C
± 0.077 °C at 200 °C
± 0.124 °C at 420 °C
Size5627A-12: 305 mm x 6.35 mm (12 in x 1/4 in)
5627A-9: 229 mm x 4.7 mm (9 in x 3/16 in)
5627A-6: 152 mm x 4.7 mm (6 in x 3/16 in)
†Includes calibration uncertainty and 100 hr drift.