Fluke Calibration 1524 Two Channel Reference Thermometer

SKU
1524-156
Manufacturer:
Fluke Calibration

Key Features:

  • High accuracy
  • PRTs: up to ± 0.011 °C
  • Thermocouples: up to ± 0.24 °C
  • Precision thermistors: ± 0.002 °C
  • Smart connectors to load probe information automatically
  • A simple user interface to quickly see trends
Product Options:
$3,159.00

Secured and trusted checkout with

     The 1523/24 Reference Thermometers from Fluke Calibration measure, graph, and record PRTs, thermocouples, and thermistors. These thermometer readouts deliver exceptional accuracy, wide measurement range, temperature logging, and trending, all in a handheld tool you can take anywhere.

     The 1523/24 lets you handle field applications, laboratory measurements, and data logging with ease. And with the dual channel measurement capabilities of the model 1524, you can do twice the work in half the time.

     The new 1524 Reference Thermometers help you do twice the work in half the time. Two channels and three sensor types and high-speed measurement make you more productive and make model 1524 the one reference thermometer you need to own. It has all the features of the 1523, and it’s a data logger too. A real-time clock and memory for 15,000 time and date stamped measurements mean everything you are going to need is in this package. Log up to three times per second, or once every hour or other options in between. Download the data to a PC for analysis when you need it.

1. RS-232 serial interface connector

2. Channel 1 sensor connector (PRT, thermocouple, and thermistor)

3. Channel 2 sensor connector (PRT, and thermistor)

4. External power adapter connection

Specifications
Input channels 2
Logging 15,000 time and date stamped; 25 readings with statistics
Sample interval
(normal)
1 second
Sample interval (fast mode) 0.3 seconds (see technical manual for details)
Sensor types PRTs, RTDs, thermistors, and thermocouples
Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
Operating temperature -10°C to 60°C (Best accuracy 13°C to 33°C)
Power requirements 3 AA alkaline batteries
Size 96 x 200 x 47 mm
(3.75 x 7.9 x 1.86 in)
Weight 0.65 kg (1.4 lb)
Environmental conditions for best accuracy 13°C to 33°C
Millivolt range and accuracy –10 mV to 75 mV ±(0.005% + 5 μV)
Resistance range and accuracy 0 Ω to 400 Ω ±(0.004% + 0.002 Ω)
200 Ω to 50 kΩ ±(0.01% + 0.5 Ω)
50 kΩ to 500 kΩ ± (0.03%)
Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C) ±(0.001%/°C + 1 μV/°C)
Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C) 0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω)
0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ)
0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ)
Excitation current, resistance 1 mA (0 Ω to 400 Ω)
10 μA (0 Ω to 50 kΩ)
2 µA (50 kΩ to 500 kΩ)
Thermocouple Equivalent Temperature Accuracies (Readout Only)
Type B ±0.85°C from 600°C to 800°C
±0.68°C from 800°C to 1000°C
±0.57°C from 1000°C to 1800°C
Type C ±0.32°C from 100ºC to 550°C
±0.71°C from 550°C to 2300°C
Type E ±0.52°C from -200°C to 0°C
±0.22°C from 0°C to 950°C
Type J ±0.52°C from -200°C to 0°C
±0.23°C from 0°C to 1200°C
Type K ±0.61°C from -200°C to 0°C
±0.24°C from 0°C to 1370°C
Type L ±0.36°C from -200°C to 0°C
±0.23°C from 0°C to 1370°C
Type M ±0.26°C from -20°C to 0°C
±0.25°C from 0°C to 400°C
±0.22°C from 400°C to 1400°C
Type N ±0.72°C from -200°C to 0°C
±0.28°C from 0°C to 1300°C
Type R ±1.09°C from -20°C to 0°C
±0.97°C from 0°C to 500°C
±0.49°C from 500°C to 1750°C
Type S ±1.05°C from -20°C to 0°C
±0.95°C from 0°C to 500°C
±0.56°C from 500°C to 1750°C
Type T ±0.60°C from -200°C to 0°C
±0.25°C from 0°C to 400°C
Type U ±0.54°C from -200°C to 0°C
±0.24°C from 0°C to 400°C
Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction.
1524 Accuracies with Selected Probes (±°C)
-200°C 5616-12: 0.014
5615-6: 0.025
5627A-12: 0.027
5610-9: n/a
0°C 5616-12: 0.021
5615-6: 0.021
5627A-12: 0.049
5610-9: 0.009
100°C 5616-12: 0.027
5615-6: 0.028
5627A-12: 0.065
5610-9: 0.009
300°C 5616-12: 0.040
5615-6: 0.043
5627A-12: 0.103
5610-9: n/a
420°C 5616-12: 0.050
5615-6: n/a
5627A-12: 0.130
5610-9: n/a
Includes readout accuracy, probe calibration, and probe drift
PRT Equivalent Temperature Accuracy (Readout only)
–100°C ±0.011
0°C ±0.015
100°C ±0.019
200°C ±0.023
400°C ±0.031
600°C ±0.039
Thermistor Equivalent Temperature Accuracy (Readout Only)
0°C ±0.002
25°C ±0.003
50°C ±0.006
75°C ±0.014
100°C ±0.030