We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Control unplanned downtime, prevent recurring problems, set repair priorities and manage your resources with an entirely new approach to vibration testing. The new Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.
You take pride in your facility, your team, and your work. You do what it takes to keep things up and running, but sometimes there is not enough time or resources to keep up with the workload, let alone be proactive about mechanical maintenance. The Fluke 810 Vibration Tester puts you one step ahead by using a simple step-by-step process to report on machine faults the first time measurements are taken, without prior measurement history. The combination of diagnoses, severity and repair recommendations help you make informed maintenance decisions and address critical problems first.
Usage
1. Vibration testing has never been easier. | |
2. Fluke 810 fits easily into your maintenance routine. | |
3. No more guessing your machine’s condition. |
Diagnostic Specifications | ||
Standard Faults | Unbalance, looseness, misalignment and bearing failures | |
Analysis For | Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles | |
Machine Rotational Speed Range | 200 rpm to 12000 rpm | |
Diagnosis Details | Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra | |
Electrical Specifications | ||
Ranging | Automatic | |
A/D Converter | 4 channel, 24 bit | |
Usable Bandwidth | 2 Hz to 20 kHz | |
Sampling | 51.2 Hz | |
Digital Signal Processing Functions | Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging | |
Sampling Rate | 2.5 kHz to 50 kHz | |
Dynamic Range | 128 dB | |
Signal To Noise Ratio | 100 dB | |
FFT Resolution | 800 lines | |
Spectral Windows | Hanning | |
Frequency Units | Hz, orders, cpm | |
Amplitude Units | in/sec, mm/sec, VdB (US), VdB* (Europe) | |
Non-volatile Memory | SD micro memory card, 2 GB internal + user accessible slot for additional storage | |
General Specifications | ||
Dimensions (H x D x W) | 18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52 in) | |
Weight (With Battery) | 1.9 kg (4.2 lb) | |
Display | ¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight | |
Input/Output Connections | Triaxial sensor connection | 4 pin M12 connector |
Single axis sensor connection | BNC connector | |
Tachometer Connection | Mini DIN 6 pin connector | |
PC Connection | Mini ‘B’ USB (2.0) connector | |
Battery | Battery type | Lithium-ion, 14.8 V, 2.55 Ah |
Battery charging time | Three hours | |
Battery discharge time | Eight hours (under normal conditions) | |
AC Adapter | Input voltage | 100 VAC to 240 VAC |
Input frequency | 50/60 Hz | |
Operating System | WinCE 6.0 Core | |
Language Support | English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish | |
Warranty | Three-years | |
Environmental Specifications | ||
Operating Temperature | 0°C to 50°C (32°F to 122°F) | |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) | |
Operating Humidity | 10% to 95% RH (non-condensing) | |
Agency Approvals | CHINA RoHS, CSA, CE, C TICK, WEEE | |
Electromagnetic Compatibility | EN 61326-1:2006, EN 61010:1:2001 2nd ed. | |
Sensor Specifications | ||
Sensor Type | Accelerometer | |
Sensitivity | 100 mV/g (±5%, 25°C) | |
Acceleration Range | 80 g peak | |
Amplitude Nonlinearity | 1% | |
Frequency Response | Z | 2 - 7,000 Hz ±3dB |
X, Y | 2 - 5,000 Hz ±3dB | |
Power Requirement (IEPE) | 18 VDC to 30 VDC, 2 mA to 10 mA | |
Bias Output Voltage | 12 VDC | |
Grounding | Case grounded | |
Sensing Element Design | PZT ceramic / shear | |
Case Material | 316L stainless steel | |
Mounting | 10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength) | |
Output Connector | 4-Pin, M12 | |
Mating Connector | M12 - F4D | |
Non-volatile Memory | TEDS 1451.4 compatible | |
Vibration Limit | 500 g peak | |
Shock Limit | 5000 g peak | |
Electromagnetic Sensitivity, Equivalent g | 100 μg/gauss | |
Sealing | Hermetic | |
Temperature Range | -50°C to 120°C (-58°F to 248°F) ±7% | |
Warranty | One-year | |
Tachometer Specifications | ||
Dimensions (D x W) | 2.86 x 12.19 cm (1.125 x 4.80 in) | |
Weight | 96 g (3.4 oz) with cable | |
Power | Powered by 810 Vibration Tester | |
Detection | Laser Diode Class 2 | |
Range | 6.0 to 99,999 rpm | |
Accuracy | 6.0 to 5999.9 rpm | ±0.01% and ±1 digit |
5999.9 to 99999 rpm | ±0.05% and ±1 digit | |
Resolution | 0.1 rpm | |
Effective Range | 1 cm to 100 cm (0.4 in to 39.27 in) | |
Response Time | 1 second (> 60 rpm) | |
Controls | Measure on/off transparent button | |
Interface | 6 Pin Mini DIN | |
Cable Length | 50 cm (19.586 in) | |
Warranty | One-year | |
Tachometer Accessories | Reflective tape | 1.5 x 52.5 cm (0.59 x 20.67 in) |
Viewer PC Software | ||
Minimum Hardware Requirements | 1 GB RAM | |
Operating System Requirements | Windows XP, Vista |
The Fluke 810 Vibration Analyzer is designed for common plant equipment, including:
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles
Rotational speed in RPM can also be measured from 200 to 12,000 RPM