We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Equipped with Fluke Connect with ShareLive™, the Fluke 805 FC Vibration Meter is the most dependable and precise meter for checking bearings and overall vibration.
The Fluke 805 FC Vibration Meter includes:
-
USB cable
Storage case
Belt holster
Quick reference guide
CD-ROM (includes MS Excel template and documentation)
Two (2) AA batteries
Specifications | |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
Severity levels | Good, satisfactory, unsatisfactory, unacceptable |
Vibration limit | 50 g peak (100 g peak-peak) |
A/D converter | 16-bit |
Signal to noise ratio | 80 dB |
Sampling rate | Low frequency: 20,000 Hz |
Real time clock backup | Coin battery |
Sensor | |
Sensitivity | 100 mV g ± 10% |
Measurement range | 0.01 g to 50 g |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range | 4,000 Hz to 20,000 Hz |
Resolution | 0.01 g |
Accuracy | At 100 Hz ± 5% of measured value |
Amplitude Units | |
Acceleration | g, m/sec² |
Velocity | in/sec, mm/sec |
Displacement | mils, mm |
Infrared Thermometer (Temperature Measurement) | |
Range | -20 °C to 200 °C (-4 °F to 392 °F) |
Accuracy | ±2 °C (4 °F) |
Focal length | Fixed, at ~3.8 cm (1.5") |
External Sensor | |
Note: Fluke supports but does not provide external sensors | |
Frequency range | 10 Hz to 1,000 Hz |
Bias voltage (to supply power) | 20 V dc to 22 V dc |
Bias current (to supply power) | Maximum 5 mA |
Firmware | |
External interfaces | USB 2.0 (full speed) communication |
Data capacity | Database on internal flash memory |
Upgrade | Through USB |
Memory | Up to 3,500 measurements |
Radiated Emission | |
Electrostatic discharge: burst | Standard EN 61000-4-2 |
Electromagnetic interference | Standard EN 61000-4-3 |
RE | Standard CISPR 11, Class A |
Environmental | |
Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
Storage temperature | -30 °C to 80 °C (-22 °F to 176 °F) |
Operating humidity | 10% to 95% RH (non-condensing) |
Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) |
IP rating | IP54 |
Vibration limit | 500g peak |
Drop test | 1 meter |
General Specifications | |
Battery type | AA (2) Lithium Iron Disulfide |
Battery life | 250 measurements |
Size (L x W x H) | 24.1 cm x 7.1 cm x 5.8 cm |
Weight | 0.40 kg (0.89 lb) |
Connectors | USB mini-B 7-pin, external sensor jack (SMB connector) |
- Reciprocating (Open motor and compressorseparate)
- Reciprocating (Hermetic motor and compressor)
- Centrifugal (Hermetic or Open Motor)
- Belt-driven Fans 1800 to 3600 RPM
- Belt-driven fans 600 to 1799 RPM
- General direct drive fans (direct coupled)
- Vacuum blowers (belt or direct drive)
- Large forced draft fans (fluid film brgs.)
- Large induced draft fans (fluid film brgs.)
- Shaft-mounted integral fan (extended motor shaft)
- Axial flow fans (belt or direct drive)
- Long, hollow drive shaft (motor)
- Belt drive (motor and fan - all arrangements)
- Direct drive (motor and fan - all arrangements)
- Vertical pumps (12’ to 20’ height)
- Vertical pumps (8’ to 12’ height)
- Vertical pumps (5’ to 8’ height)
- Vertical pumps (0’ to 5’ height)
- Horizontal centrifugal end suction pumps – directcoupled
- Horizontal centrifugal double suction pumps –direct coupled
- Boiler feed pumps (turbine or motor driven)
- Positive displacement horizontal piston pumps(under load)
- Positive displacement horizontal gear pumps (underload)
- Reciprocating
- Rotary screw
- Centrifugal with or without external gearbox
- Centrifugal – internal gear (axial meas.)
- Centrifugal – internal gear (radial meas.)
- Lobe-type rotary blowers (belt or direct drive)
- Multi-stage centrifugal blowers (direct drive)
- Motor
- Gearbox input
- Gearbox output
- Spindles – roughing operations
- Spindles – machine finishing
- Spindles – critical finishing
- Single stage gearbox