Fluke has introduced their 62 MAX+/T+PRO/1AC IR Thermometer, T+PRO Voltage Continuity Tester and Voltage Detector Kit for comprehensive, rapid problem solving. Users can benefit from the Fluke 62 MAX+ with a 12: distance to spot ratio, while the Fluke T+PRO offers 3 different parameters of AC/DC voltage detection: light, sound and vibration. Even more, the Fluke 1AC II VoltAlert is capable of voltage detection of 90 to 1000 VAC.
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 | |
Response time (95%) | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |
Fluke T+PRO Electrical Testers
Specifications | ||
Temperature | Operating | -10°C to 55°C (14°F to 131°F) |
Storage | -30°C to 60°C (-22°F to 140°F) | |
Relative humidity | 0°C to 30°C (32°F to 86°F): 90% | |
30°C to 40°C (86°F to 104°F): 75% | ||
40°C to 50°C (104°F to 122°F): 45% | ||
Altitude | Operating | 2,000 m (approx. 6,561.6 ft) |
Storage | 10,000 m (approx. 32,808.4 ft) | |
Battery type/life | AAA (2); 40 hours | |
Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument | |
Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV | |
Compliance to NFPA 70E1 | ||
AC bandwidth | 45 Hz to 66 Hz | |
Maximum working voltage | 1000 V AC/DC | |
Maximum measurable voltage | 600 V AC/DC | |
Duty cycle | Indefinitely for voltages up to 240 V | |
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off | ||
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s | ||
Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC ±35% | |
LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | |
LED voltage indication levels for Canadian version | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD accuracy on T+PRO only | AC voltage | ±(3% rdg + 2 digits) |
DC voltage | ±(2% rdg + 2 digits) | |
Resistance | ±(5% rdg + 3 digits) | |
LCD resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V 0.01 kΩ for resistance measurement (For T+PRO Only) | |
GFCI test current | 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA | |
Standard input test current | < 5 mA | |
Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm) | |
Weight | 9.9 oz (0.28 kg) | |
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment. |
Fluke 1AC-II VoltAlert
Specifications | ||
Operating principle | Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. | |
Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model | |
Detector tip style | Blade or round, depending on model | |
Light source | One high intensity red LED | |
Agency approvals | c CSA us, CE, C-Tick | |
Safety rating | 1000 V, CAT IV | |
IP rating | IP 40 | |
Operating temperature | -10°C to 50°C | |
Operating humidity ranges | 0% to 95% | (0°C to 30°C) |
0% to 75% | (30°C to 40°C) | |
0% to 45% | (40°C to 55°C) | |
Operating altitude | 3000 meters | |
Batteries | 2 AAA alkaline batteries included | |
Product does not respond to random electrostatic discharge. |