Fluke 3540 FC KIT Three-Phase Power Monitor

SKU
FLUKE-3540 FC KIT
Manufacturer:
Fluke
Fluke

Key Features:

  • Monitor three-phase systems and wirelessly streams data to the Fluke Connect Cloud
  • Access and track data as well as receive alarms to a mobile device or PC through Fluke Connect Condition Monitoring software
  • Measures:
    • Single, split, or three-phase loads
    • Current, voltage, and frequency
    • Total harmonic distortion
    • Power including active, non-active power and power factor
$4,140.00

Secured and trusted checkout with

The Fluke 3540 FC KIT is a compact device used to monitor key electrical parameters at three-phase machinery and seamlessly stream data to the Fluke Connect Cloud.

 

Fluke Connect

Set up and sustain preventive maintenance procedures easily using the Fluke Connect® system of wireless test tools and asset management software.

  • • Improve your ability to prevent or predict machine failures
  • • Make confident decisions with data you can trust and track
  • • Access your infrared images from anywhere, anytime with secure cloud storage
  • • Connect and collaborate with your team – even when you are in different places
  • • Provide more complete information to your maintenance teams
  • • Generate work orders that include measurements and infrared images
  • • Edit and analyze images; create and send reports from your smartphone directly from the field
General specifications
Color LCD display4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty3540 FC and built-in power supply2 years (battery not included)
Accessories1 year
Calibration cycle2 years
Dimensions (wxhxd)3540 FC19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Detachable power supply13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
3540 FC with power supply attached19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 4.0 in)
Weight3540 FC1.1kg (2.5 lb)
Power Supply
Tamper protectionKensington lock
Environmental specifications
Operating temperatureO °C to 45 °C (32 °F to 113 °F)
Storage temperature<20 °C to +60 °C (-4 °C to +140 °F), with battery: -20 °C to +50 °C (-4 °F to +122 °F)
Operating humidity<10 °C (<50 °F) non condensing
10 °C to 30 °C (50 °F to 86 °F) ≤95 %
30 °C to 40 °C (86 °F to 104 °F) ≤75 %
40 °C to 45 °C (104 °F to 113 °F) ≤45 %
Operating altitude2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude12,000 m (39,000 ft)
IP ratingIEC 60529:IP50, in connected condition with protection caps in place
VibrationMIL-T-28800E, Type 3, Class III, Style B
Safety
IEC 61010-1IEC mains inputOvervoltage Category II, Pollution Degree 2
Voltage terminalsOvervoltage Category IV, Pollution Degree 2
Electromagnetic compatibility (EMC)
InternationalIEC 61326-1: Industrial
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter
Frequency range2412 MHz to 2462 MHz
Output power<100 mW
Electrical specifications
Single and Three Phase Topologies
Wiring configurations1-Φ, 1-Φ IT, Split phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Voltage inputs
Number of inputs4 (3 phases and neutral)
Maximum input voltage1000 Vrms (1700 Vpk) phase to neutral
Input impedence10 MΩ each phase to neutral
Bandwidth42.5 Hz to 3.5 kHz
Scaling1:1, variable
Current inputs
Number of inputs3, mode selected automatically for attached sensor
Current sensor output voltageClamp500 mVrms / 50 mVrms; CF 2.8
Rogowski coil150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Bandwidth (-3 dB)42.5 Hz to 3.5 kHz
Scaling1:1 and variable
Data acquisition
Resolution16-bit synchronous sampling
Sampling frequency10.24 kHz at 50/60Hz, synchronized to mains frequency
Input signal frequencyMains 50/60 Hz (42.5 to 69 Hz)
Data storageInternal flash memory (not user replaceable)
Memory sizeTypical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.
Measured parametersVoltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
Averaging interval1 s
Total harmonic distortionTHD for voltage and current is calculated on 25 harmonics
Calculated min/max values times
VoltageFull cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ)
CurrentHalf cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
Power200 ms
Interfaces
USB-AFirmware updates, max. supply current: 120 mA
WiFi
Supported modesDirect connection and connection to infrastructure
SecurityWPA2-AES with pre-shared key
Power supply
Voltage rangenominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
Mains powernominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
Power consumptionMaximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Standby power<0.3 W only when powered using IEC 60320 input
Efficiency≥ 68.2 % (in accordance with energy efficiency regulations)
Mains frequency50/60 Hz ± 15 %
Battery powerLi-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtimeUp to 4 hr (up to 5.5 hr in energy saving mode)
Charging time<6 hr