The Fluke 190-202-III is part of the Fluke 190 Series III ScopeMeter series that has 2 channels with a bandwidth of 200 MHz and 1.7 ns rise time.
Includes:
- • ScopeMeter 190-202-III
- • BC190/830 power adapter
- • Power cord set
- • BP290 Li-ion battery pack
- • TL175 test lead set
- • VPS410-II probe (2x)
- • Hand strap
- • Hanging strap
- • USB-cable
- • Printed instructions
Oscilloscope modes
| 190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 |
Vertical deflection | |||||||
Number of channels | 2 | 2 | 2 | 2 | 4 | 4 | 4 |
Bandwidth | 60 MHz | 100 MHz | 200 MHz | 500 MHz | 100 MHz | 200 MHz | 500 MHz |
Rise time | 5.8 ns | 3.5 ns | 1.7 ns | 0.7 ns | 3.5 ns | 1.7 ns | 0.7 ns |
Number of scope inputs | 2 input channels plus external trigger | 4 input channels | |||||
Channel architecture | All inputs fully insulated from each other and from ground. Inputs may be activated in any combination | ||||||
Input coupling | AC or DC, with ground level indicator | ||||||
| With 10:1 probe, 20 mV to 1000 V/div | ||||||
Bandwidth limiter | 20 MHz and 10 kHz | ||||||
Polarity | Normal, Inverted, Variable | ||||||
Input voltage | CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details | ||||||
Vertical resolution | 8 bit | ||||||
Accuracy at 4 s to 10 ps/div | 5 mV/div to 100 V/div, ±(1.5 % + 6 counts) | ||||||
Input impedance | 1 MO (± 1 %) // 15 pF (± 2.25 pF) |
| 190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 |
Horizontal | |||||||
Maximum real-time sample rate (sampled simultaneously) | 625 MS/s | 1.25 GS/s | 2.5 GS/s | 5 GS/s (single | 1.25 GS/s | 2.5 GS/s (2ch) | 5 GS/s (single |
Record length | Up to 10,000 samples per channel | ||||||
| 10 ns/div | 5 ns/div | 2 ns/div | 1 ns/div | 5 ns/div | 2 ns/div | 1 ns/div |
Time base in a 1-2-4-sequence | |||||||
Maximum record length | 10,000 samples per channel in scope mode | ||||||
Timing accuracy | ± (0.01 % of reading + 1 pixel) | ||||||
Glitch capture | 8 ns (10 µs/div to 2 min/div) |
Display and acquisition | |
Display | 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD |
Display modes | Any combination of channels; average on/off; replay. |
Visible screen width | 12 divisions horizontally in scope mode |
Digital persistence modes | Off, short, medium, long, infinite and envelope mode |
Waveform mathematics | One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): |
Acquisition modes | Normal, Averaged, Auto, Single Shot, ScopeRecordTM roll, glitch capture, |
Trigger and delay | ||
Source | Input A, B or External (via meter input) | Input A, B, C or D |
Modes | Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2) | |
| Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred. | |
Pulse width triggering (on channel A) | Pulse width qualified by time |
Time delay | 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay |
Dual slope triggering | Triggers on both rising and falling edges alike |
N-cycle triggering | Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99 |
Automatic capture of 100 screens | |
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events. | |
Replay | Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp. |
Replay storage | Ten sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port. |
FFT—frequency spectrum analysis | |
Shows frequency content of oscilloscope waveform using Fast Fourier Transform | |
Window | Automatic, Hamming, Hanning or None |
Automatic window | Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant. |
Vertical scale | Linear/Logarithmic (in volts or amps) |
Frequency axis | Frequency range automatically set as a function of timebase range of oscilloscope |
Waveform compare and pass/fail testing | |
Waveform compare | Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope. |
Pass/Fail testing | In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis. |
Automatic scope measurements | |
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio | |
Advanced power and motor drive functions | V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters |
Cursor measurements | |
Source | On any input waveform or on mathematical resultant waveform (excl. X-Y-mode) |
Dual horizontal lines | Voltage at cursor 1 and at cursor 2, voltage between cursors |
Dual vertical lines | Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors. |
Single vertical line | Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant |
Advanced functions | mA*s (current-over-time, between cursors); V*s (voltage over time, between cursors); W*s (energy, between cursors) |
ZOOM | Ranges from full record overview to zoom in up to sample level, at any record length. |
Meter modes
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Meter inputs | Via 4 mm banana inputs, fully isolated from scope inputs and scope ground | Via BNC scope inputs | |||||
Number of | One at a time via DMM input | Up to 4 automatic scope measurements simultaneously | |||||
Maximum | 5,000 counts | ± 999 counts | |||||
Input impedance | 1 MΩ (± 1 %) // 14 pF (± 1.5 pF) | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | |||||
Advanced meter functions | Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording | ||||||
The specified accuracy is valid over the temperature range 18 °C to 28 °C | |||||||
Voltage | |||||||
V dc accuracy | ± (0.5 % + 6 counts) | ± (1.5 % + 6 counts) | |||||
V ac true rms accuracy | |||||||
15 Hz to 60 Hz | ± (1 % + 10 counts) | ± (1.5 % + 10 counts) | |||||
60 Hz to 1 kHz | ± (2.5 % + 15 counts) | — | |||||
60 Hz to 20 kHz | — | ± (2.5 % + 15 counts) | |||||
V ac+dc true rms accuracy | |||||||
15 Hz to 60 Hz | ± (1 % + 10 counts) | ± (1.5 % + 10 counts) | |||||
60 Hz to 1 kHz | ± (2.5% + 15 counts) | — | |||||
60 Hz to 20 kHz | — | ± (2.5 % + 15 counts) | |||||
Voltmeter ranges | 500 mV, 5 V, 50 V, 500 V, 1,100 V | ||||||
Resistance | |||||||
Ranges | 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | — | |||||
Accuracy | ± (0.6 % + 6 counts) | — | |||||
Other meter functions | |||||||
Continuity | Beeper on < 50 Ω (± 30 Ω) | — | |||||
Diode test | Up to 2.8 V | — | |||||
Current (A) | A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A | ||||||
Temperature | With optional accessories. Scale factors 1mV/°C or 1mV/°F |
Recorder mode
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
ScopeRecord™ Roll Mode | |||||||
Dual or multiple input waveform storage mode, using deep memory | |||||||
Source and | Input A, Input B, Dual | Any combination of inputs, up to 4 channels. All channels sampled simultaneously | |||||
Memory depth | 30,000 data points per channel, each holding min/max pair of information | ||||||
Min/max values | Min/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches. | ||||||
Recording | Single sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external) | Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel) | |||||
Stop-on-trigger | ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series) | ||||||
Horizontal scale | Time from start, time of day | ||||||
Zoom | Ranges from full record overview to zoom in up to sample level | ||||||
Memory | Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis. | ||||||
ScopeRecord™ Roll mode sample rate and recording timespan | |||||||
Time base range | 4 ms/div to 2 min/div | ||||||
Recorded timespan | 4.8 sec to 40 hr | ||||||
Time/division in | 0.4 s/div to 4 h/div | ||||||
Glitch capture | 8 ns | ||||||
Sample rate | 125 MS/s | ||||||
Resolution | 160 μsec ~ 4.8 sec | ||||||
Trendplot™ Recording | |||||||
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time. | |||||||
Source and display | Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments) | ||||||
Memory depth | 19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp. | ||||||
Ranges | Normal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record) | ||||||
Recorded time span | Up to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings. | ||||||
Recording mode | Continuous recording, starting at 5 s/div with automatic time-scale compression | ||||||
Measurement speed | Three automatic measurements per second or more | ||||||
Horizontal scale | Time from start, time of day | ||||||
Zoom | Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail | ||||||
Memory | Two multiple input TrendPlot records can be saved internally for later recall and analysis. | ||||||
Cursor measurements—all recorder modes | |||||||
Source | Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot) | ||||||
Dual vertical lines | Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time. |
General specifications
| 190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 |
Input voltage range | |||||||
Rated maximum | CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level) | ||||||
Probe input voltage VPS410-II | CAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead) | ||||||
Probe input voltage VPS421 | CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead) | ||||||
Maximum BNC input voltage | CAT IV 300 V (maximum voltage on BNC input directly) | ||||||
Maximum voltage on meter input | CAT III 1000 V / CAT IV 600 V | — | |||||
Memory save and recall | |||||||
Memory locations | 30 waveform memories plus 10 recording memories plus 9 screen copy memories | ||||||
30 waveform memories | Each memory can contain up to 2 or 4 waveforms plus corresponding setups. | ||||||
10 recording memories | Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements | ||||||
External data storage | On PC, using FlukeViewTM-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port | ||||||
Screencopies | On PC, using FlukeViewTM-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port | ||||||
Volatility | Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status. | ||||||
Real-time clock | Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings. | ||||||
Case | |||||||
Design | Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard. Kensington lock supported to lock down instrument when left unattended. | ||||||
Drip and dust proof | IP 51 according to IEC60529 | ||||||
Shock and vibration | Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2 | ||||||
Display size | 133 mm x 90 mm (5.3 in x 3.5 in) LCD | ||||||
Resolution | 1120 pixels x 765 pixels | ||||||
Brightness | User-adjustable, up to 300 cd/m2 | ||||||
Mechanical data | |||||||
Size | 265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in) | ||||||
Weight | 2.1 kg (4.6 lb) | 2.2 kg (4.8 lb) | |||||
Power | |||||||
Line power | Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz | ||||||
Battery power | Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument | ||||||
Battery type (incl.) and capacity [+opt. battery] | BP290: 10.8V, 2500 mAh | BP291: 10.8V, 5000 mAh | |||||
Battery charge | Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen. | ||||||
Battery operating | Up to 3.5 using BP290 (included), up to 7 hours using BP291 (optional) | Up to 7 hours using BP291 (included) | |||||
Battery | 2½ hours using BP290; 5 hours using BP291 | Five hours for BP291 | |||||
Battery | Auto ‘power down’ with adjustable power down time. | ||||||
Safety | |||||||
Compliance | EN61010-1, Pollution Degree 2; | ||||||
Environmental | |||||||
Operating | Battery discharging: 0 °C to 40 °C (32 °F to 104 °F) | ||||||
Storage | -20 °C to 60 °C (-4 °F to 140 °F) | ||||||
Humidity | 0 °C to 10 °C (32 °F to 50 °F): noncondensing | ||||||
Maximum | CAT IV 600 V, CAT III 1000 V: up to 2000 m (6 600 feet) | ||||||
Maximum | 12 km (40,000 ft) | ||||||
Electro- | IEC 61326-1: Industrial; | ||||||
Interfaces | Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry. USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFiAdapter for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2. | ||||||
Probe | Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel. | ||||||
Warranty | 3 years on main instrument, 1 year on battery and accessories |