Fluke 1623-2 Kit GEO Earth Ground Tester

SKU
FLUKE-1623-2 KIT
Manufacturer:
Fluke
Fluke

Key Features:

  • One-button measurement concept
  • 3- and 4-pole earth ground measurement
  • 2-pole resistance measurement AC
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Measuring frequency 128 Hz
Product Options:
$4,649.99

Secured and trusted checkout with

The Fluke 1623-2 Kit is a unique earth ground tester that can execute all four types of earth ground measurement. Specifically, the Fluke 1623-2 Kit is able to measure earth ground loop resistances using only clamps called Stakeless test.

Testing Methods:

  • 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
  • Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
  • Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.

The Fluke 1623-2 Kit Includes:

  • GEO Earth Ground Tester
  • User’s Manual
  • Batteries
  • Quick Reference Guide
  • USB Cable
  • 2 Clamps
  • C1620 Professional Carrying Case
  • 4 Earth Ground Stakes
  • 3 Cable Reels
General Specifications
Display: 1999 digit LCDDisplay with special symbols, digit height 25 mm, fluorescent backlight
User interfaceInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, water and dust resistantInstrument is designed for tough environmental conditions (rubber protective cover, IP56)
MemoryInternal memory storage up to 1500 records accessible via USB port
Temperature Range
Operating temperature-10°C to 50°C (14°F to 122°F)
Storage temperature-30°C to 60°C (-22°F to 140°F)
Temperature coefficient±0.1% of reading/°C < 18°C > 28°C
Intrinsic errorRefers to the reference temperature range and is guaranteed for 1 year
Operating errorRefers to the operating temperature range and is guaranteed for 1 year
Climatic classC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH
Protective typeIP56 for case, IP40 for battery door according to EN60529
SafetyProtection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree 2
EMC (emission immunity)IEC61326-1: Portable
Quality systemDeveloped, designed and manufactured according to DIN ISO 9001
External voltageV ext, max = 24 V (DC, AC < 400 Hz), measurement inhibited for higher values
V ext rejection> 120 dB (162⁄3, 50, 60, 400 Hz)
Measuring timeTypical 6 seconds
Max. overload250 V rms (pertains to misuse)
Auxiliary power6 x 1.5 V Alkaline (type AA LR6)
Battery life spanTypical > 3,000 measurements
Dimensions (W x H x D)250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
Weight1.1 kg (2.43 lb) including batteries
7.6 kg (16.8 lb) incl. accessories and batteries in carrying case
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch positionRA 3-pole
Resolution0.001 Ω to 10 Ω
Measuring range0.020 Ω to 19.99 kΩ
Accuracy±(2% rdg + 3 d)
Operating error±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring voltageVm = 48 V AC
Short-circuit current> 50 mA
Measure frequency128 Hz
Probe resistance (RS)Max 100 kΩ
Auxiliary earth electrode resistance (RH)Max 100 kΩ
Additional error from RH and RSRH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch positionRA 4-pole
Resolution0.001 Ω to 10 Ω
Measuring range0.020 Ω to 19.99 kΩ
Accuracy±(2% rdg + 3 d)
Operating error±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring voltageVm = 48 V AC
Short-circuit current> 50 mA
Measure frequency128 Hz
Probe resistance (RS + RES)Max 100 kΩ
Auxiliary earth electrode resistance (RH)Max 100 kΩ
Additional error from RH and RSRH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp )
Switch positionRA 3-pole with clamp
Resolution0.001 Ω to 10 Ω
Measuring range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating error±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring voltageVm = 48 V AC
Short-circuit current> 50 mA
Measure frequency128 Hz
Probe resistance (RS)Max 100 kΩ
Auxiliary earth electrode resistance (RH)Max 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp )
Switch positionRA 4-pole with clamp
Resolution0.001 Ω to 10 Ω
Measuring range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating error±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring voltageVm = 48 V AC
Short-circuit current> 50 mA
Measure frequency128 Hz
Probe resistance (RS)Max 100 kΩ
Auxiliary earth electrode resistance (RH)Max 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch positionRA 4-pole 2 clamps
Resolution0.001 Ω to 10 Ω
Measuring range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating error±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring voltageVm = 48 V AC
Measure frequency128 Hz
Noise current (IEXT)Max. IEXT = 10 A (AC) (RA < 20 Ω)
Max. IEXT = 2 A (AC) (RA > 20 Ω)
Automatic range selection.
The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.

 
Fluke 1623 Kit Includes:

  • -Fluke 1623 tester
  • -2 test leads
  • -4 earth ground stakes
  • -3 cable reels with wire (2-25 m, 1-50 m)
  • -2 clamps (one inducing, one sensing)
  • -Batteries
  • -Users Manual
  • -Rugged Carrying Case

 

 

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $2,744.99

As low as

Now $4,499.99

As low as

Now $5,749.99