Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

SKU
FLUKE-1587/MDT FC
Manufacturer:
Fluke
Fluke

Key Features:

The Fluke 1587 FC 2-in-1 Insulation DMM

  • Pl/DAR measurements with TrendIt™ graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test voltages 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Insulation test: 0.1 MΩ to 600 MΩ
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency / Capacitance / Diode test / Temperature
  • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
  • Resistance (0.1 Ω to 50 MΩ) / Continuity / Auto power off
  • Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case 

Fluke i400 AC Current Clamp

  • Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
  • 1 mA/Amp output guarantees easy reading
  • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
  • Specially designed to offer maximum utility in a very compact shape
  • Maximum conductor: Ø 32 mm
  • 1 year warranty

Fluke 9040 Phase Rotation Indicator

  • Large display to easily determine field rotation and phase sequence
  • Indication for all three phases
  • CAT III 600 V overvoltage rating
  • 2 year warranty
Product Options:
$1,568.99

Secured and trusted checkout with

The Fluke 1587/MDT FC Avanced Motor and Drive Troubleshooting Kit includes the Fluke 1587 FC 2-in-1 Insulation DMM, the Fluke i400 Current Clamp and the Fluke 9040 Phase Rotation Indicator. With the Fluke Connect Measurement app, the 1587 FC now has 4 new features such as, eliminating the need to write down results with the Fluke Connect memory storage. The i400 allows for accurate measurements of currents without breaking electrical circuits. Even more, the Fluke 9040 offers quick determination of phase sequence.

 

Fluke 1587 FC Insulation Multimeter

Electrical Specifications

AC voltage measurement

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)¹

1000 V

Resolution

1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(2% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)¹

¹ 1 kHz bandwidth

Low-Pass Filter Voltage 

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

1000 V

Resolution

1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(2% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

DC Voltage Measurement

Range

Resolution

Accuracy ±(% of Rdg + Counts)

6.000 V dc

0.001 V

±(0.09% + 2)

60.00 V dc

0.01 V

±(0.09% + 2)

600.0 V dc

0.1 V

±(0.09% + 2)

1000 V dc

1 V

±(0.09% + 2)

Input impedance 

10 MΩ (nominal), <100 pF

Normal mode rejection ratio 

>60 dB @ 50 Hz or 60 Hz

Common mode rejection ratio 

>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)

Accuracies apply to ± 100% of range

DC Millivolts Measurement

Range

Resolution

Accuracy ±(% of Rdg + Counts)

600.0 mVdc

0.1 mV

±(0.1% + 1)

DC and AC Current Measurement

AC 45 Hz to 1000 Hz

Range

400 mA

Resolution

0.1 mA

Accuracy ±(% of Rdg+Counts)

±(1.5% + 2)¹

Burden voltage (Typical)

2 mV/mA

Range

60 mA 

Resolution

0.01 mA 

Accuracy ±(% of Rdg+Counts)

±(1.5% + 2)¹

Burden voltage (Typical)

2 mV/mA

DC

Range

400 mA

Resolution

0.1 mA

Accuracy ±(% of Rdg+Counts)

±(0.2% + 2)

Burden voltage (Typical)

2 mV/mA

Range

60 mA

Resolution

0.01 mA

Accuracy ±(% of Rdg+Counts)

±(0.2% + 2)

Burden voltage (Typical)

2 mV/mA

Overload

600 mA for 2 minutes maximum

Fuse protection for mA input

0.44 mA, 1000 V, IR 10 kA

AC conversion

Inputs are ac-coupled and calibrated to the rms value of sine wave input

Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.

¹ 1 kHz bandwidth

Ohms Measurement

Range

Resolution

Accuracy +(% of Rdg+Counts)¹

600.0 Ω

0.1 Ω

±(0.9% + 2)

6.000 kΩ

0.001 kΩ

±(0.9% + 2)

60.00 kΩ

0.01 kΩ

±(0.9% + 2)

600.0 kΩ

0.1 KΩ

±(0.9% + 2)

6.000 MΩ

0.001 MΩ

±(0.9% + 2)

50.0 MΩ ²

0.01 MΩ

±(1.5% + 3)

Overload protection 

1000 V rms or dc

Open circuit test voltage 

<8.0 V dc

Short circuit current 

<1.1 mA

¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity

Diode Test

Diode test indication

Display voltage drop: 0.6 V at1.0 mA nominal test current:

Accuracy

±(2% + 3)

Continuity Test

Continuity indication

Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω

Open circuit voltage

<8.0 V

Short circuit current

1.0 mA typical

Overload protection

1000 V rms

Response time

>1 m sec

Frequency Measurement

Range

Resolution

Accuracy ±(% of Rdg+Counts)

99.99 Hz 

0.01 Hz 

±(0.1% + 1)

999.9 Hz 

0.1 Hz 

±(0.1% + 1)

9.999 kHz 

0.001 kHz 

±(0.1% + 1)

99.99 kHz 

0.01 kHz 

±(0.1% + 1)

Frequency Counter Sensitivity

600.0 mV ac 

V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

100.0 mV 

V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

150.0 mV 

DC Trigger Levels¹ to 20 kHz²

NA

6.0 V 

V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

1.0 V 

V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

1.5 V 

DC Trigger Levels¹ to 20 kHz²

-400.0 mV and 2.5 V

60.0 V 

V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

10.0 V 

V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

36.0 V 

DC Trigger Levels¹ to 20 kHz²

1.2 V and 4.0 V

600.0 V 

V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

100.0 V 

V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

-

DC Trigger Levels¹ to 20 kHz²

12.0 V and 40.0 V

1000.0 V 

V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

300.0 V 

V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

-

DC Trigger Levels¹ to 20 kHz²

12.0 V and 40.0 V

¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input

Capacitance

Range 

Resolution 

Accuracy ±(% of Rdg+Counts)

1000 nF 

1 nF

±(1.2% + 2)

10.00 μF 

0.01 μF

±(1.2% + 2)

100.0 μF 

0.1 μF

±(1.2% ±90 counts)

9999 μF 

1 μF

±(1.2% ±90 counts)

Temperature Measurement

Range 

Resolution 

Accuracy ±(% of Rdg+Counts)¹

-40 ° C to 537 ° C 

0.1 °C 

±(1% + 10 counts)

-40 ° F to 998 ° F 

0.1 °F 

±(1% + 18 counts)

¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument

Insulation Specifications

Measurement range

0.01 MΩ to 2 GΩ

Test voltages

50, 100, 250, 500, 1000 V

Test voltage accuracy

+20%, -0%

Short-circuit test current

1 mA nominal

Auto discharge

Discharge time <0.5 second for C = 1 μF or less

Live circuit detection

Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum capacitive load

Operable with up to 1 μF load

Output Voltage

50 V (0% to +20%)

Display range

0.01 to 6.00 MΩ

Resolution

0.01 MΩ

Test current

1 mA @ 50 kΩ

Resistance accuracy ±(% of Rdg + Counts)

±(3% + 5 counts)

Display range

6.0 to 50.0 MΩ

Resolution

0.1 MΩ

Test current

1 mA @ 50 kΩ

Resistance accuracy ±(% of Rdg + Counts)

±(3% + 5 counts)

100 V (0% to +20%)

Display range

0.01 to 6.00 MΩ

Resolution

0.01 MΩ

Test current

1 mA @ 100 kΩ

Resistance accuracy ±(% of Rdg + Counts)

±(3% + 5 counts)

Display range

6.0 to 60.0 MΩ

Resolution

0.1 MΩ

Test current

1 mA @ 100 kΩ

Resistance accuracy ±(% of Rdg + Counts)

±(3% + 5 counts)

Display range

60 to 100 MΩ 

Resolution

1 MΩ

Test current

1 mA @ 100 kΩ

Resistance accuracy ±(% of Rdg + Counts)

±(3% + 5 counts)

250 V (0% to +20%)

Display range

0.1 to 60.0 MΩ 

Resolution

0.1 MΩ

Test current

1 mA @ 250 kΩ 

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

Display range

60 to 250 MΩ 

Resolution

1 MΩ

Test current

1 mA @ 250 kΩ 

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

500 V (0% to +20%)

Display range

0.1 to 60.0 MΩ

Resolution

0.1 MΩ

Test current

1 mA @ 500 kΩ 

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

Display range

60 to 500 MΩ

Resolution

1 MΩ

Test current

1 mA @ 500 kΩ 

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

1000 V (0% to +20%)

Display range

0.1 to 60.0 MΩ 

Resolution

0.1 MΩ

Test current

1 mA @ 1 MΩ

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

Display range

60 to 600 MΩ 

Resolution

1 MΩ

Test current

1 mA @ 1 MΩ

Resistance accuracy ±(% of Rdg + Counts)

±(1.5% + 5 counts)

Display range

0.6 to 2.0 GΩ 

Resolution

100 MΩ 

Test current

1 mA @ 1 MΩ

Resistance accuracy ±(% of Rdg + Counts)

±(10% + 3 counts)

General Specifications

Maximum voltage applied to any terminal and common

1000 V

Storage temperature

-40 °C to 60 °C (-40 °F to 140 °F)

Operating temperature

-20 °C to 55 °C (-4 °F to 131 °F)

Temperature coefficient

0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)

Relative humidity

Noncondensing

0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)

0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)

0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)

Vibration

Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Radio frequency communication

2.4 GHz ISM Band

Radio frequency certification

FCC: T68-FBLE, IC: 6627A-FBLE

Electromagnetic Compatibility 

International

IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A

Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.

Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

USA (FCC)

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Enclosure protection

IEC 60529: IP40 (non-operating)

Safety

IEC 61010-1

Pollution Degree 2

IEC 61010-2-033

CAT IV 600 V / CAT III 1000 V

Batteries 

Four AA batteries (NEDA 15A or IEC LR6)

Battery life

Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.

Size (H x W x L)

5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

Weight

550 g (1.2 lb)

Altitude

Operating

2000 m

Storage

12,000 m

Over-range capability

110% of range except for capacitance which is 100%

Frequency overload protection

<107 V Hz

Fuse protection for mA input

0.44A, 1000 V, IR 10 kA

Fluke i400 AC Current Clamp

Specifications

Nominal current range

400  A

Continuous current range

1 A - 400 A

Maximum non-destructive current

1000 A

Lowest measurable current

1 A

Basic accuracy

2% + 0.06 A

(45-400 Hz)

(% reading + floorspec)

Useable frequency

5 Hz - 20 kHz

Output level(s)

1 mA/A

Safety Specifications

Safety

CAT IV 600 V, CAT III, 1000 V

Maximum voltage

1000 V AC rms from earth to ground, in compliance with EN61010

Mechanical and General Specifications

Warranty

1 year

Maximum conductor diameter

32 mm (1.25 in)

Maximum conductor size (busbar)

750 MCM

Output cable length

1.5 m (59 in)

Shrouded banana plugs

Yes

Fluke 9040 Phase Rotation Indicator

Technical Specifications

Voltage range

40-700 V

Frequency range

15-400 Hz

Operating timer

Continuous

Environmental Specifications

Operating temperature

0 °C to 40 °C

Dust/water resistance

IP 40

Safety Specifications

Electrical safety

EN 61010,  EN 61557-7

Overvoltage category

CAT III, 600 V

CAT IV, 300V

Mechanical and General Specifications

Size

124 x 61 x 27 mm

Weight

200 g

Power supply

From unit under test

Warranty

2 years

 

 

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $972.99

As low as

Now $1,038.99

As low as

Now $1,189.99

As low as

Now $1,304.99