Fluke 124B/S 40 MHz ScopeMeter FlukeView Software SCC Kit

SKU
FLUKE-124B/NA/S
Manufacturer:
Fluke
Fluke

Key Features:

  • 40 MHz oscilloscope bandwidth
  • Two 5,000-count true-rms digital multimeters
  • Dual channle oscilloscope and multimeter
  • CAT IV 600 V High Safety Rating
  • FlukeView® ScopeMeter® Software for Windows®
  • Fluke Connect now built-in
  • Connect-and-View™ trigger simplicity for hands-off operation
  • IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
  • Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
  • Resistance, continuity, diode and capacitance meter measurements
  • Dual-input waveform and meter reading recorder for trending data over extended periods
  • External optically isolated USB interface to transfer, archive and analyze scope or meter data
  • Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
  • Shielded test leads for oscilloscope, resistance and continuity measurements
  • Li-Ion rechargeable battery, seven-hours operation (with four-hour charge time)
  • Save or recall data and instrument setups
  • Optional WiFi adapter connects USB port
  • Wirelessly transfers information to the PC, laptop or Fluke Connect® mobile app
  • Rugged sealed housing meets IP51 and EN/IEC60529
Product Options:
$3,255.99

Secured and trusted checkout with

The Fluke 124B/S Hand-Held Industrial ScopeMeter with FlukeView software SCC Kit is conceived to aid technicians in troubleshooting faster and providing the solutions needed to keep systems up and working. The 124B/S is equipped the latest technologies from Fluke, like the Connect-and-View trigger setup technology and the IntellaSet technology which reduces the need for manual measurement adjustments. Its FlukeView ScopeMeter Software for Windows has revolutionized the process of analyzing data. The software allows for screen images to be copied into reports and documents and stored on the PC in color, waveform data from the ScopeMeter to be captured and stored on the PC and waveform references to be created and archived for easy comparison. 

 

Get more out of your ScopeMeter 120B with FlukeView® Software included in the SCC Kit option:

 

  • Store instrument’s screen copies on the PC, in color
  • Copy screen images into your reports and documentation
  • Capture and store waveform data from your ScopeMeter on your PC
  • Create and archive waveform references for easy comparison
  • Copy waveform data into your spreadsheet for detailed analysis
  • Use cursors for parameter measurement

Add user text to instrument setups and send them to the instrument for the operator

The Fluke 124B/S replaces the Fluke 124-S scope meter.

 

Measure Multiple Electrical Parameters 

 

Save time by removing the need to swap leads

  

Comprehensive Recorder Modes 

 Eliminate the process of searching through tons of data to isolate faults

  

Connect-and-View 

The Connect-and-View triggering technology instantly identifies signal changes and makes the appropriate adjustments. 

 

Dual Input

Attain crucial power characteristics to validate a system power

 

Fluke Connect

Fluke Connect is the most comprehensive software and wireless test tools family that keeps you in contact with your entire team without leaving the field. The Fluke Connect software is compatible with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation), HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher and works with now over 30 different Fluke products. The Fluke Connect family offers the largest system of connected test tools in the world.  Please see out Fluke Connect category for the complete collection of Fluke Connect Products.  
Take me to Fluke Connect (Click Here). 

 

Includes:

 

  • Fluke 124B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
  • Soft Carrying Case
  • Magnetic Hanger
  • FlukeView® ScopeMeter® Software for Windows®
  • Screen Protector

 

 

Oscilloscope mode

Vertical

Frequency response - dc coupled

Without probes and test leads (with BB120)

dc to 40 MHz (-3 dB)

With STL120-IV 1:1 shielded test leads

DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)

With VP41 10:1 Probe

dc to 40 MHz (-3 dB)

Frequency response - ac coupled (lf roll off)

Without probes and test leads

<10 Hz (-3 dB)

With STL120-IV 1:1 shielded test leads

<10 Hz (-3 dB)

With VP41 10:1 Probe

<10 Hz (-3 dB)

Rise time, excluding probes, 
test leads

<8.75 ns

Input impedance

Without probes and test leads

1 MΩ//20 pF

With BB120

1 MΩ//24 pF

With STL120-IV 1:1 shielded test leads

1 MΩ//230 pF

With VP41 10:1 Probe

5 MΩ//15.5 pF

Sensitivity

5 mV to 200 V/div

Analog bandwidth limiter

10 kHz

Display modes

A, -A, B, -B

Max. input voltage A and B

Direct, with test leads, or with VP41 Probe

600 Vrms Cat IV, 750 Vrms maximum voltage.

With BB120

600 Vrms

Max. floating voltage, from any terminal to ground

600 Vrms Cat IV, 750 Vrms up to 400Hz

Horizontal

Scope modes

Normal, Single, Roll

Ranges (normal)

Equivalent sampling

10 ns to 500 ns/div

Real time sampling

1 μs to 5 s/div

Single (real time)

1 μs to 5 s/div

Roll (real time)

1s to 60 s/div

Sampling rate (for both channels simultaneously)

Equivalent sampling (repetitive signals)

Up to 4 GS/s

Real time sampling 1 μs to 60 s/div

40 MS/s

 

Trigger

Screen update

Free run, on trigger

Source

A, B

Sensitivity A and B

@ DC to 5 MHz

0.5 divisions or 5 mV

@ 40 MHz

1.5 divisions

@ 60 MHz

4 divisions

Slope

Positive, negative

 

Advanced scope functions

Display modes

Normal

Captures up to 25 ns glitches and displays analog-like persistence waveform

Smooth

Suppresses noise from a waveform

Glitch off

Does not capture glitches between samples

Envelope

Records and displays the minimum and maximum of waveforms over time

Auto set (Connect-and-View™)

Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.

 

Dual input meter

The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.

Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.

 

Input A and input B

DC voltage (VDC)

Ranges

500 mV, 5 V, 50 V, 500 V, 750 V

Accuracy

±(0.5% +5 counts)

Common mode rejection (CMRR)

>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz

Full scale reading

5000 counts

True-rms voltages (V ac and V ac+dc)

Ranges

500 mV, 5 V, 50 V, 500 V, 750 V

Accuracy for 5% to 100% of range (DC coupled)

DC to 60 Hz (V ac+dc)

±(1% +10 counts)

1 Hz to 60 Hz (V ac)

±(1% +10 counts)

Accuracy for 5% to 100% of range (AC or dc coupled)

60 Hz to 20 kHz

±(2.5% +15 counts)

DC rejection (only VAC)

>50 dB

Common mode rejection (CMRR)

>100 dB @ dc

>60 dB @ 50, 60, or 400 Hz

Full scale reading

5000 counts, reading is independent of any signal crest factor.

Peak

Modes

Max peak, Min peak, or pk-to-pk

Ranges

500 mV, 5 V, 50 V, 500 V, 2200 V

Accuracy

Accuracy Max peak or Min peak

5% of full scale

Accuracy Peak-to-Peak

10% of full scale

Full scale reading

500 counts

Frequency (Hz)

Ranges

1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz

Frequency range

15 Hz (1 Hz) to 50 MHz in continuous autoset

Accuracy @1 Hz to 1 MHz

±(0.5% +2 counts)

Full scale reading

10,000 counts

RPM

Max reading

50.00 kRPM

Accuracy

±(0.5% +2 counts)

Duty cycle (PULSE)

Range

2% to 98%

Frequency range

15 Hz (1 Hz) to 30 MHz in continuous autoset

Pulse width (PULSE)

Frequency range

15 Hz (1 Hz) to 30 MHz in continuous autoset

Full scale reading

1000 counts

Amperes (AMP)

With current clamp

Ranges

Same as V dc, V ac, V ac+dc, or PEAK

Scale factors

0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA

Accuracy

Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)

Temperature (TEMP) with optional temperature probe

Range

200 °C/div (200 °F/div)

Scale factor

1 mV/°C and 1 mV/°F

Accuracy

As V dc (add temp. probe uncertainty)

Decibel (dB)

0 dBV

1 V

0 dBm (600 Ω /50 Ω)

1 mW referenced to 600 Ω or 50 Ω

dB on

V dc, V ac, or Vac+dc

Full scale reading

1000 counts

Crest factor (CREST)

Range

1 to 10

Full scale reading

90 Counts

Phase

Modes

A to B, B to A

Range

0 to 359 degrees

Resolution

1 degree

Vpwm

Purpose

To measure on pulse width modulated signals, like motor drive inverter outputs

Principle

Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency

Accuracy

As Vrms for sinewave signals

 

Input A to common

Ohm (Ω)

Ranges

 

500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ

Accuracy

±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)

Full scale reading

50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts

Measurement current

0.5 mA to 50 nA, decreases with increasing ranges

Open circuit voltage

<4 V

Continuity (Cont)

Beep

<(30 Ω ±5 Ω) in 50 Ω range

Measurement current

0.5 mA

Detection of shorts of

≥1 ms

Diode

Measurement voltage

@0.5 mA

>2.8 V

@open circuit

<4 V

Measurement current

0.5 mA

Polarity

+ on input A, - on COM

Capacitance (CAP)

Ranges

50 nF, 500 nF, 5 μF, 50 μF, 500 μF

Full scale reading

5000 counts

Measurement current

500 nA to 0.5 mA, increases with increasing ranges

 

Advanced meter functions

Zero Set

Set actual value to reference

AutoHold (on A)

Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.

Fixed decimal point

Activated by using attenuation keys

 

Cursor Readout

Sources

A, B

Single vertical line

Average, min and max readout

Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)

Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)

Harmonics values in POWER QUALITY mode.

Dual vertical lines

Peak-peak, time distance and reciprocal time distance readout

Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)

Dual horizontal lines

High, low and peak-peak readout

Rise or fall time

Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
possible in single channel mode)

Accuracy

As oscilloscope accuracy

 

Recorder

The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card

The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.

Meter readings

Measurement Speed

Maximum 2 measurement/s

Record Size (min, max, average)

2 M readings for 1 channel

Recorded Time Span

2 weeks

Maximum number of events

1024

Waveform record

Maximum sample rate

400 K sample/s

Size Internal memory

400 M samples Recorded Time

Span internal memory

15 minutes at 500 μs/div
11 hours at 20 ms/div

Record Size SD card

1.5 G samples

Recorded Time Span SD card

11 hours at 500 μs/div
14 days at 20 ms/div

Maximum number of events

64

 

Miscellaneous

Display

Type

5.7-inch color active matrix TFT

Resolution

640 x 480 pixels

Waveform Display

Vertical

10 div of 40 pixels

Horizontal

12 div of 40 pixels

Power

External

Via Power Adapter BC430

Input voltage

10 V DC to 21 V DC

Power consumption

5 W typical

Input connector

5 mm jack

Internal

Via Battery Pack BP290

Battery power

Rechargeable Li-Ion 10.8 V

Operating time

7 hours with 50% backlight brightness

Charging time

4 hours with test tool off,  7 hours with test tool on

Allowable ambient temp

0 to 40 °C (32 to 104 °F) during charging

Memory

Internal memory can store 20 data sets  (screen waveform and setup)

Micro SD card slot with optional SD card  (max size of 32 GB)

Mechanical

Size

259 x 132 x 55 mm 
(10.2 x 5.2 x 2.15 in)

Weight

1.4 kg (3.2 lb) including battery pack

Interface

Optically isolated

Transfer screen copies (bitmaps), settings and data

USB to PC/laptop

OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.

Optional WiFi adapter

Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.

 

Environmental

Environmental

MIL-PRF-28800F, Class 2

Temperature

Battery Operation

0 to 40 °C (32 to 104 °F)

Power Adapter Operation

0 to 50 °C (32 to 122 °F)

Storage

-20 to 60 °C (-4 to 140 °F)

Humidity (Operating)

@ 0 to 10 °C (32 to 50 °F)

Non-condensing

@ 10 to 30 °C (50 to 86 °F)

95%

@ 30 to 40 °C (86 to 104 °F)

75%

@ 40 to 50 °C (104 to 122 °F)

45%

Storage

@ -20 to 60 °C (-4 to 140 °F)

Non-condensing

Altitude

Operating at 3 km (10,000 feet)

CAT III 600 V

Operating at 2 km (6,600 feet)

CAT IV 600 V

Storage

12 km (40,000 feet)

EMC electromagnetic compatibility

International

IEC 61326-1: Industrial, CISPR 11:  Group 1, Class A

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

USA (FCC)

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Wireless radio with adapter

Frequency range

2412 MHz to 2462 MHz

Output power

<100 mW

Enclosure protection

IP51, ref: EN/IEC60529

Safety

General

IEC 61010-1: Pollution Degree 2

Measurement

IEC 61010-2-033: CAT IV 600 V/CAT III 750 V

Max. input voltage input A and B

Direct on input or with leads

600 Vrms CAT IV for derating

With Banana-to-BNC Adapter BB120

600 Vrms for derating

Max. floating voltage from any terminal to ground

600 Vrms Cat IV, 750 Vrms up to 400 Hz

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $1,929.99

As low as

Now $2,512.99

As low as

Now $2,740.99

As low as

Now $3,360.99