We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Fluke 123B Hand-Held Industrial ScopeMeter with SCC Kit provides simplified testing and faster troubleshooting. In one piece of equipment, the Fluke 123B integrates oscilloscope, multimeter and high speed recorder for an advanced level of troubleshooting in a variety of applications. Equipped with, IntellaSet technology, Connect-and-View trigger and setup technology and Fluke Connect compatibility, the 123B has become the top solution for electro-mechanical maintenance.
Get more out of your ScopeMeter 120B with FlukeView® Software included in the SCC Kit option:
- Store instrument’s screen copies on the PC, in color
- Copy screen images into your reports and documentation
- Capture and store waveform data from your ScopeMeter on your PC
- Create and archive waveform references for easy comparison
- Copy waveform data into your spreadsheet for detailed analysis
- Use cursors for parameter measurement
- Add user text to instrument setups and send them to the instrument for the operator
The Fluke 123B/S replaces the Fluke 123-S.
Connect-and-View
The Connect-and-View triggering technology identifies signal patterns, sets up the correct triggering to provide a stable reliable repeatable display automatically.
Comprehensive Recorder Modes
Plot the minimum and maximum peak measurement values, record waveform trace to identify and troubleshoot intermittent faults
Measure Multiple Electrical Parameters
Meter, high frequency waveform, resistance and capacitance measurements in addition to continuity checks are all reported by a single set of test leads.
Dual Input
Measure AC & DC RMS Voltage on channel A and AC & DC RMS Current on channel B
Fluke Connect
Fluke Connect is the most comprehensive software and wireless test tools family that keeps you in contact with your entire team without leaving the field. The Fluke Connect software is compatible with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation), HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher and works with now over 30 different Fluke products. The Fluke Connect family offers the largest system of connected test tools in the world. Please see out Fluke Connect category for the complete collection of Fluke Connect Products.
Take me to Fluke Connect (Click Here).
Includes:
- Fluke 123B Hand-Held Oscilloscope
- Shielded Test Leads with Black Ground Leads
- Test Lead Black (for Grounding)
- Hook Clips (red, blue)
- Banana-to-BNC Adapters (black, x1)
- USB Angled Adapter
- WiFi USB Adapter*
- Switch Mode Power Supply, Adapter/Battery Charger
- Rechargeable Li-ion Battery Pack
- Soft Carrying Case
- Magnetic Hanger
- FlukeView® ScopeMeter® Software for Windows®
- Screen Protector
Oscilloscope mode | ||
Vertical | ||
Frequency response - dc coupled | Without probes and test leads (with BB120) | dc to 20 MHz (-3 dB) |
With STL120-IV 1:1 shielded test leads | DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB) | |
With VP41 10:1 Probe | dc to 20MHz (-3 dB) | |
Frequency response - ac coupled (lf roll off) | Without probes and test leads | <10 Hz (-3 dB) |
With STL120-IV 1:1 shielded test leads | <10 Hz (-3 dB) | |
With VP41 10:1 Probe | <10 Hz (-3 dB) | |
Rise time, excluding probes, | <17.5 ns | |
Input impedance | Without probes and test leads | 1 MΩ//20 pF |
With BB120 | 1 MΩ//24 pF | |
With STL120-IV 1:1 shielded test leads | 1 MΩ//230 pF | |
With VP41 10:1 Probe | 5 MΩ//15.5 pF | |
Sensitivity | 5 mV to 200 V/div | |
Analog bandwidth limiter | 10 kHz | |
Display modes | A, -A, B, -B | |
Max. input voltage A and B | Direct, with test leads, or with VP41 Probe | 600 Vrms Cat IV, 750 Vrms maximum voltage. |
With BB120 | 600 Vrms | |
Max. floating voltage, from any terminal to ground | 600 Vrms Cat IV, 750 Vrms up to 400Hz | |
Horizontal | ||
Scope modes | Normal, Single, Roll | |
Ranges (normal) | Equivalent sampling | 20 ns to 500 ns/div, |
Real time sampling | 1 μs to 5 s/div | |
Single (real time) | 1 μs to 5 s/div | |
Roll (real time) | 1s to 60 s/div | |
Sampling rate (for both channels simultaneously) | Equivalent sampling (repetitive signals) | Up to 4 GS/s |
Real time sampling 1 μs to 60 s/div | 40 MS/s |
Trigger | ||
Screen update | Free run, on trigger | |
Source | A, B | |
Sensitivity A and B | @ DC to 5 MHz | 0.5 divisions or 5 mV |
@ 40 MHz | 4 divisions | |
Slope | Positive, negative |
Advanced scope functions | ||
Display modes | Normal | Captures up to 25 ns glitches and displays analog-like persistence waveform |
Smooth | Suppresses noise from a waveform | |
Glitch off | Does not capture glitches between samples | |
Envelope | Records and displays the minimum and maximum of waveforms over time | |
Auto set (Connect-and-View™) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level. |
Dual input meter |
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C. |
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen. |
Input A and input B | ||
DC voltage (VDC) | ||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
Accuracy | ±(0.5% +5 counts) | |
Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
Full scale reading | 5000 counts | |
True-rms voltages (V ac and V ac+dc) | ||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
DC rejection (only VAC) | >50 dB | |
Common mode rejection (CMRR) | >100 dB @ dc | |
>60 dB @ 50, 60, or 400 Hz | ||
Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
Peak | ||
Modes | Max peak, Min peak, or pk-to-pk | |
Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
Accuracy Peak-to-Peak | 10% of full scale | |
Full scale reading | 500 counts | |
Frequency (Hz) | ||
Ranges | 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
Full scale reading | 10,000 counts | |
RPM | ||
Max reading | 50.00 kRPM | |
Accuracy | ±(0.5% +2 counts) | |
Duty cycle (PULSE) | ||
Range | 2% to 98% | |
Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
Pulse width (PULSE) | ||
Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
Full scale reading | 1000 counts | |
Amperes (AMP) | ||
With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
Temperature (TEMP) with optional temperature probe | ||
Range | 200 °C/div (200 °F/div) | |
Scale factor | 1 mV/°C and 1 mV/°F | |
Accuracy | As V dc (add temp. probe uncertainty) | |
Decibel (dB) | ||
0 dBV | 1 V | |
0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
dB on | V dc, V ac, or Vac+dc | |
Full scale reading | 1000 counts | |
Crest factor (CREST) | ||
Range | 1 to 10 | |
Full scale reading | 90 Counts | |
Phase | ||
Modes | A to B, B to A | |
Range | 0 to 359 degrees | |
Resolution | 1 degree | |
Vpwm | ||
Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
Accuracy | As Vrms for sinewave signals |
Input A to common | ||
Ohm (Ω) | ||
Ranges | 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | |
Accuracy | ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts) | |
Full scale reading | 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts | |
Measurement current | 0.5 mA to 50 nA, decreases with increasing ranges | |
Open circuit voltage | <4 V | |
Continuity (Cont) | ||
Beep | <(30 Ω ±5 Ω) in 50 Ω range | |
Measurement current | 0.5 mA | |
Detection of shorts of | ≥1 ms | |
Diode | ||
Measurement voltage | @0.5 mA | >2.8 V |
@open circuit | <4 V | |
Measurement current | 0.5 mA | |
Polarity | + on input A, - on COM | |
Capacitance (CAP) | ||
Ranges | 50 nF, 500 nF, 5 μF, 50 μF, 500 μF | |
Full scale reading | 5000 counts | |
Measurement current | 500 nA to 0.5 mA, increases with increasing ranges |
Advanced meter functions | |
Zero Set | Set actual value to reference |
AutoHold (on A) | Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. |
Fixed decimal point | Activated by using attenuation keys |
Recorder | |
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. | |
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples. | |
Meter readings | |
Measurement Speed | Maximum 2 measurement/s |
Record Size (min, max, average) | 2 M readings for 1 channel |
Recorded Time Span | 2 weeks |
Maximum number of events | 1024 |
Waveform record | |
Maximum sample rate | 400 K sample/s |
Size Internal memory | 400 M samples Recorded Time |
Span internal memory | 15 minutes at 500 μs/div |
Record Size SD card | 1.5 G samples |
Recorded Time Span SD card | 11 hours at 500 μs/div |
Maximum number of events | 64 |
Miscellaneous | ||
Display | Type | 5.7-inch color active matrix TFT |
Resolution | 640 x 480 pixels | |
Waveform Display | Vertical | 10 div of 40 pixels |
Horizontal | 12 div of 40 pixels | |
Power | External | Via Power Adapter BC430 |
Input voltage | 10 V DC to 21 V DC | |
Power consumption | 5 W typical | |
Input connector | 5 mm jack | |
Internal | Via Battery Pack BP290 | |
Battery power | Rechargeable Li-Ion 10.8 V | |
Operating time | 7 hours with 50% backlight brightness | |
Charging time | 4 hours with test tool off, 7 hours with test tool on | |
Allowable ambient temp | 0 to 40 °C (32 to 104 °F) during charging | |
Memory | Internal memory can store 20 data sets (screen waveform and setup) | Micro SD card slot with optional SD card (max size of 32 GB) |
Mechanical | Size | 259 x 132 x 55 mm |
Weight | 1.4 kg (3.2 lb) including battery pack | |
Interface | Optically isolated | Transfer screen copies (bitmaps), settings and data |
USB to PC/laptop | OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®. | |
Optional WiFi adapter | Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons. |
Environmental | ||
Environmental | MIL-PRF-28800F, Class 2 | |
Temperature | Battery Operation | 0 to 40 °C (32 to 104 °F) |
Power Adapter Operation | 0 to 50 °C (32 to 122 °F) | |
Storage | -20 to 60 °C (-4 to 140 °F) | |
Humidity (Operating) | @ 0 to 10 °C (32 to 50 °F) | Non-condensing |
@ 10 to 30 °C (50 to 86 °F) | 95% | |
@ 30 to 40 °C (86 to 104 °F) | 75% | |
@ 40 to 50 °C (104 to 122 °F) | 45% | |
Storage | @ -20 to 60 °C (-4 to 140 °F) | Non-condensing |
Altitude | Operating at 3 km (10,000 feet) | CAT III 600 V |
Operating at 2 km (6,600 feet) | CAT IV 600 V | |
Storage | 12 km (40,000 feet) | |
EMC electromagnetic compatibility | International | IEC 61326-1: Industrial, CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Wireless radio with adapter | Frequency range | 2412 MHz to 2462 MHz |
Output power | <100 mW | |
Enclosure protection | IP51, ref: EN/IEC60529 | |
Safety | General | IEC 61010-1: Pollution Degree 2 |
Measurement | IEC 61010-2-033: CAT IV 600 V/CAT III 750 V | |
Max. input voltage input A and B | Direct on input or with leads | 600 Vrms CAT IV for derating |
With Banana-to-BNC Adapter BB120 | 600 Vrms for derating | |
Max. floating voltage from any terminal to ground | 600 Vrms Cat IV, 750 Vrms up to 400 Hz |