Fluke 116/62 MAX+ Technician's Combo Kit

SKU
FLUKE-116/62 MAX+
Manufacturer:
Fluke
Fluke

Key Features:

Fluke 116 HVAC Multimeter

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance helps prevent false readings due to ghost voltage
  • Work in poorly lit areas with the Large white LED backlit display
  • True-rms voltage and current for accurate measurements on non-linear loads
  • Measures 10 A directly (20 A overload for 30-seconds) without a current clamp
  • Resistance, continuity, frequency and capacitance
  • Record signal fluctuations using Min/Max/Average and elapsed time stamps
  • Easy to use with one hand
  • Hands free operation with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated

Fluke 62 MAX+ Infrared Thermometer

  • Measure -30°C to 650°C (-22°F to 1202°F)
  • Extremely accurate: up to +1.0°C or + 1.0% of reaching (Fluke 62 MAX+)
  • IP54 rating for water resistance and dust proof allow you to work rain or shine and even in the most dirty or dusty industrial sites
  • Strong enough to withstand a 3m drop. No worry even if you work from a ladder
  • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
  • Dual lasers: The 62 MAX+ has dual lasers to help you identify area to be measured
Product Options:
Special Price $323.99 Regular Price $359.99

Secured and trusted checkout with

Fluke’s 116/62 MAX+ Technician's Combo Kit delivers users with a Fluke 116 Multimeter and a Fluke 62 MAX+ Infrared Thermometer for versatility and efficiency in a single kit.

 

The Fluke 116 is suited for resistance, frequency, continuity and capacitance measurements, in addition to providing Min/Max/Average readings with elapsed time for documenting signal fluctuations. It’s equipped with the Fluke 80BK-A integrated DMM temperature probe and a microamp function for flame sensor measurements down to 0.1 microamps. For reliable precision, an AutoV/LoZ function eliminates false readings as a result of ghost voltages.

 

The 62 MAX+ Infrared Thermometer is compact without compromising accuracy. Even more, the IR thermometer’s durable construction can sustain a 3-meter drop and resist dust and water with its IP54 rating.

Fluke 116 Multimeter

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating Temperature-10°C to +50°C
Storage Temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/Resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMSRange600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
OhmsRange/Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy1.5% + 2
Diode TestRange/Resolution2.000 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/Resolution> 1000 μF
Accuracy5% + 20%
LoZ capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
Temperature2 (Type-K thermocouple)Range/Resolution-40°C to 400°C / 0.1°C
Accuracy21% + 10
Range/Resolution-40°F to 752°F / 0.2°F
Accuracy21% + 18
AC μamps true-rms (45 Hz to 500 Hz)Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
DC μampsRange/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)2Range/Resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

 

Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

 

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range-30°C to 650°C (-22°F to 1202°F)
Accuracy±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%)< 300 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical resolution12:1 (calculated at 90% energy)
Display resolution0.1°C (0.2°F)
Repeatability of readings±0.5% of reading or <±0.5°C (1°F), whichever is greater
PowerAA battery
Battery life8 hours with laser and backlight on
Physical Specifications
Weight255 g (8.99 oz)
Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
IP ratingIP 54 per IEC 60529
Drop test3 meters
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006 EN 61326-2:2006
Standards and agency approvalComplianceEN/IEC 61010-1: 2001
Laser safetyFDA and EN 60825-1 Class II
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account