Flowline EchoPod DL24 provides continuous level measurement up to 9.8 (3m) with a 4-20 mA signal output, and is configured via our free Webcal software. The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware.This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications.
Range: | 9.8' (3m) |
Accuracy: | ± 0.2% of range |
Resolution: | 0.039" (1mm) |
Dead band: | 4" (10cm) |
Beam width: | 2" (5cm) |
Configuration: | WebCal® PC Windows® USB 2.0 |
Memory: | Non-volatile |
Supply voltage: | 24 VDC (loop) |
Consumption: | 0.5W |
Loop resist.: | 400Ω max |
Signal output: | 4-20 mA, two-wire |
Signal invert: | 4-20 mA or 20-4 mA |
Signal fail-safe: | 4 mA, 20 mA, 21 mA, 22 mA or hold last |
Contact type: | (4) SPST relays |
Contact rating: | 60 VA, 1A maximum |
Contact fail-safe: | Power loss: Hold last Echo loss: Open, close or hold last |
Hysteresis: | Selectable |
Process temp.: | F: -4° to 140° C: -20° to 60° |
Temp. comp.: | Automatic |
Ambient temp.: | F: -31° to 140° C: -35° to 60° |
Pressure: | MWP = 30 PSI (2 bar) |
Enclosure rating: | Type 6P, encapsulated, corrosion resistant & submersible |
Encl. material: | Polycarbonate |
Trans. material: | PVDF |
Cable jacket mat.: | Polyurethane |
Cable type: | 9-conductor, shielded |
Cable length: | 48" (1.2m) |
Process mount: | 1" NPT (1" G) |
Mount gasket: | Viton® |
Classification: | General purpose |
Compliance: | CE, RoHS |
Approvals: | cFMus |
Write Your Own Review
Small Atmospheric Day Tank, Skid or Process Vessel, Lift Station, IBC, Drum and Sump