Extech RD200 Refrigerant Leak Detector - DISCONTINUED

SKU
RD200
Manufacturer:
Extech
Extech

Key Features:

This Product is DISCONTINUED

  • Detects all standard refrigerants using a heated diode sensor (SF6, HFC, CFC, HCFC refrigerants, halogen gas, ethylene, tetrafluoroethylene, trichloroethylene, and most other compounds containing halogen)
  • User-selectable sensitivity level:
    • Low - 1.05oz (30g) per year
    • High - 0.2oz (6g) per year
  • Multi-colored LED light bar indicates the level of refrigerant leakage detected
  • 19.8" (50.2cm) flexible gooseneck retains its shape and provides easy access in difficult to reach locations
  • Audible and Visual alert
  • Low battery indicator
  • Convenient field replaceable sensor (RD200-S)
  • Leak Test Bottle included for a quick and easy self test on meter performance
  • Dimensions:
    • Meter - 7.3x2.8x1.4" (185x72x35mm)
    • Sensor with Gooseneck - 20.5" (520mm) long
    • Probe Diameter - 0.32" (8mm)
  • Weight: 12oz (340g)
  • Complete with sensor (installed), leak test bottle, 9V battery, and protective hard carrying case
Call For Price

Secured and trusted checkout with

Extech's RD200 Refrigerant Leak Detector is simple to use and is perfect for identifying leaks from air-conditioning units and cooling systems that use all standard refrigerants. The multi-colored LED light bar displays the level of refrigerant detected by the RD200. The unit features a field replaceable heated diode sensor and Low/High sensitivity range selection for accurate leak detection. The 16" (406mm) flexible gooseneck provides effortless access in hard to reach locations.
Detectable RefrigerantsSF6 electrical equipment and gas, HFC, CFC, HCFC refrigerants,
HFC (R134 and R123), halogen gas, ethylene, tetrafluoroethylene,
trichloroethylene, and most compounds containing halogen.
SensorReplaceable heated diode gas detector (part no. RD200-S)
Accuracy< 2.8g/year (0.1oz./year)
Sensitivity LevelsLow 30g/year (1.05oz./year)
High 6g/year (0.2oz./year)
Test Bottle Solution1:1 ethanol (95%) and distilled water
Warm up Time2 minutes (approx.)
Response TimeInstantaneous
Auto Power OFFAutomatic shut off after 10 minutes
Low Battery IndicationBattery status LED glows red
Power Supply9V Battery (rear compartment under protective jacket)
Battery Life30 hours of normal use
Operating Conditions0°C to 50°C (32°F to 122°F) <80%RH
Storage Conditions-10°C to 80°C (14°F to 176°F) <70%RH
Length: Flexible Gooseneck only50.2cm (19.8”)
Length: Gooseneck w/ Sensor52cm (20.5”)
Meter Dimensions / Weight185 x 72 x 35mm (7.3 x 2.8 x 1.4”) / 340g (12 oz.)
SafetyCE; Designed to SAE J1627

 

 

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account