BK Precision DAS30 2 Channel High Speed Multi-Function Recorder

SKU
DAS30
Manufacturer:
B&K Precision
B&K Precision

Key Features:

  • Fast 1 MSa/s sample rate (memory mode) and 100 kHz bandwidth for capturing intermittent events
  • Accurately view and record signals from ±5 mV to ±500 and 424 VRMS
  • CAT III 600 V rated isolated channels
  • Wide 10-inch touchscreen TFT display
  • Capture mixed signals with one instrument, such as high voltage, current waveforms, temperature, and logic data
  • Battery life up to 9.5 hours
  • 32 GB internal solid-state memory
  • 2 analog input channels
  • 14-bit resolution
  • 16 logic input channels
  • Temperature measurements supporting thermocouples and Pt100/Pt1000 RTD sensors (factory option on DAS30/50)
  • 2 USB host ports and one LAN interface
  • 110 mm thermal printer (factory option)
Product Options:
$3,480.00

Secured and trusted checkout with

BK Precision’s DAS30 2 Channel High Speed Multi-Function Recorder comes equipped with 2 analog input channels and the capacity for 32 GB (DAS30/50) internal solid-state memory. The DAS30 boasts versatile channel configurability, fast sampling (1 MSa/s), an expansive input range (±5 mV to ±500 V) and up to 9.5 hours of battery life. Users can capture transit events in file mode with the 2 µs sampling interval while the vast memory allows for data to be recorded over extended periods of time.

Each channel is constructed to record a different signal like temperature, voltage, current or frequency simultaneously, using a common time base. The user friendly touch screen allows for efficient features like zooming, data scrolling and the ability to drag and drop delta cursors for precision measurements. Built with a CAT III isolation rating, the BK Precision DAS 32 is perfect for applications from small sensor signal logging to electrical power analysis.

Universal Inputs

 

Number of Channels

DAS30

2

DAS50

4

DAS60

6

Voltage

Maximum Input Voltage

±500 VDC or 424 VRMS

Maximum Offset

± 5 ranges  (up to ± 500 V)

Accuracy

0.1% of the full scale ±10 µV

True RMS AC/DC Ranges

200 mV to 424 V

Response Time

100 ms typical (40 ms to 50 Hz)

Crest Factor

2.2 and 600 V Max

Input Impedance (DC)

> 25 MΩ for upper ranges < 1 V,

1 MΩ for upper ranges, 150 pF typical

Channel Isolation

> 100 MΩ at 500 VDC

Bandwidth and Filters

 

Bandwidth (-3 dB)

> 1 V

100 kHz

> 50 mV

50 kHz

5 mV

20 kHz

True RMS AC/DC Bandwidth

5 Hz to 500 Hz

Internal Analog Filters

10 kHz, 1 kHz, 100 Hz, 10 Hz

Slope

20 dB/decade

Programmable Digital Filters

10 Hz, 1 Hz, 0.1 Hz, 0.01 Hz, 0.001 Hz

Sensitivity

100 mV RMS min.

Duty Cycle

10% min.

Frequency Range

0.1 Hz to 100 kHz

Basic Accuracy

0.02% of full scale

Data Acquisition and Trigger

Resolution

14 bit

 

Fastest Sampling Interval

(single channel)

 

File mode

Memory mode

DAS30

5 µs (200 kSa/s)

 

1 µs  (1 MSa/s)

DAS50

DAS60

2 µs (500 kSa/s)

Memory Length (memory mode)

32 M word segments  up to 128 blocks

Triggering

Positive edge, negative edge, on logic input, delay, go no go

Pre-trigger

±100%

Temperature with Thermocouples





Sensor Range by Type (cold junction compensation: ±0.5 °C)

J

410 °F to 2192 °F (210 °C to 1200 °C)

K

482 °F to 2498 °F (250 °C to 1370 °C)

T

392 °F to 752 °F (200 °C to 400 °C)

S

122 °F to 3200 °F (50 °C to 1760 °C)

B

392 °F to 3308 °F (200 °C to 1820 °C)

E

482 °F to 1832 °F (250 °C to 1000 °C)

N

482 °F to 2372 °F (250 °C to 1300 °C)

C

32 °F to 4208 °F (0 °C to 2320 °C)

L

392 °F to 1652 °F (200 °C to 900 °C)

Power Analysis Function

Networks

Single phase, 3 phase

Display

Fresnel diagram, oscilloscope, data

Measurements

Mean value, RMS, peak, crest factor, THD and DF for voltage

& current,  active, reactive and apparent power, power factor (ø)

Harmonics

Calculated up to rank 50, with display and record

Logic Input

Channels

16

TTL Maximum Voltage

24 V

Sampling Interval

1 µs (1 MSa/s)  per channel

Sensor Supply

9 to 15 VDC

Alarms 2

A & B 0 to 5 V output

Pt100/Pt1000 (factory option for DAS30 & DAS50)

Number of Channels

2

Current

1 mA for Pt100, 100 µA for Pt1000

Resolution

20 bits

Temperature Range

-392 °F to 1562 °F (-200 °C to +850 °C)

Measurements

2, 3, 4 wires

Accuracy @ 20 ºC

±0.2 °C

Printer (factory option for all models)

Paper Width

110 mm

Paper Speed

1 mm/min. to 25 mm/s

Paper Speed

10 mm/s max. (memory mode)

 

Resolution

Y axis

8 dots/mm

X axis

16 dots/mm

XY mode

8 dots/mm (both axis)

General

Internal Solid State Memory (file mode)

32 GB (DAS30, DAS50)

64 GB (DAS60)

Operating Temperature

0 °C to 40 °C, 80% RH (no condensation)

Storage Temperature

-68 °F to 140 °F (-20 °C to 60 °C)

Display

10” TFT touchscreen LCD, backlit, 1024 x 600 dots

Power Supply

15 V / 4 A max with main adapter (100 / 240 VAC)

Interfaces

2 x USB host, LAN (10/100 base-T  with RJ45 socket)

Battery

Non removable, Lithium-ion

 

Typical Battery Life

9.5 hours with standby mode,

4 hours without standby mode

Safety

IEC 61010 - CAT III 600 V

Weight

5.5 lbs (2.5 kg)

Dimensions  (W x H x D)

 

8.25” x 11.5” x 4.1” (210  x 295  x 105 mm)

Warranty

Two Years

 

Supplied Accessories

AC mains adapter 100 / 240 V, rugged carrying case, CAT III banana  test leads(2) + alligator clips(2), bare wire to banana adapters(2), 25 pin male connector(1)  and backshell, soft wipe, stylus, screwdriver, roll of thermal printer paper (-P models),calibration  certificate & test report

(1) User configurable with solder cups.
(2) One set per channel

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Measure signals ranging from small sensors to large electrical systems
  • Maintenance and failure analysis
  • Power analysis of single and three-phase systems

Products In This Series

As low as

Now $4,560.00

As low as

Now $6,990.00