We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Madgetech Element CO 2 wireless data logger is equipped to measure and record carbon dioxide, humidity and temperature levels for agricultural applications. It’s the all-in-one solution for acquiring a complete environmental profile.
The Element CO 2 comes supplied with a 16 ft. cable connected to the CO 2 sensor, making it perfect for placement around grow rooms or greenhouses to ensure prime levels. This device features an LCD screen which allows users quick access to current readings, minimum, maximum and average statistics. The logger has user-programmable alarms that alert and notify users via email or text when thresholds are breached, allowing for instant action.
The Element CO 2 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
The Element CO 2 is also MadgeTech Cloud Services ready, providing users the ability to monitor real-time data remotely on any internet enabled device, from anywhere in the world.
Note: RFC wireless interface required.
General
Memory | 10,752 readings (all channels enabled) |
Reading Rate | 1 reading every second up to 1 reading every 24 hours |
Baud Rate | 250,000 |
LED Indicators | Green, Blue & Red |
Battery Life | 16 months typical at a 10 minute reading rate |
Material | ABS plastic |
Dimensions | Data logger: 3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) Sensor: 1.98 in x 1.98 in x 1.15 in (50.3 mm x 50.3 mm x 29.2 mm) Cable Length: 16 ft (192 in) |
IP Rating | IP22 |
Operating Environment | 0 °C to +55 °C (+32 °F to +131 °F), 0 %RH to 95 %RH non-condensing, 13.77 PSIA to 100 PSIA |
Required Interface Package | RFC1000 |
Approvals | US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE) |
Temperature
Internal Channel Temperature Sensor | Silicon |
Internal Channel Temperature Range | 0 °C to +55 °C (+32 °F to +131 °F) |
Internal Channel Temperature Resolution | 0.08 °C (0.144 °F) |
Internal Channel Temperature Calibrated Accuracy | ±1.0 °C |
Humidity
Humidity Sensor | Silicon |
Humidity Range | 0 %RH to 95 %RH |
Humidity Resolution | 0.08 %RH |
Humidity Calibrated Accuracy | ±3.0 %RH from 25 %RH to 75 %RH @ 25 °C, 7 %RH otherwise |
Carbon Dioxide
Carbon Dioxide Range | 0 ppm to 200,000 ppm |
Carbon Dioxide Resolution | 10 ppm |
Carbon Dioxide Accuracy | 70 ppm ± 5% of the reading |
Wireless
RF Baud Rate | 250,000 |
Output Power | +0 dBm typical |
Receiver Sensitivity | -95 dBm typical |
Typical outdoors Line of sight | Up to 2000 ft |
Typical Indoors line of sight | Up to 500 ft |
- • Incubator Monitoring
- • Building Studies (hospitals, schools, offices)
- • HVAC System Testing
- • Agricultural Studies
- • Indoor Air Quality (IAQ) Studies