The Continental Control Systems ACTL-0750-200 Opt C0.6 is a revenue grade split-core current transformer that offers outstanding linearity and very low phase angle error with easy one-handed opening and closing and has a maximum continuous amps of 200.
Accuracy | 0.50% |
Rated Amps | 20, 50, 100, 200, 250* |
Optional Rated Amps | 15, 30, 70, 150 |
Accuracy Class | IEEE/ANSI C57.13, Class 0.6 |
CE Accuracy | IEC 60044-1 Class 0.5 S |
CE Safety | CE |
RoHS Compliance | √ |
UL USA | UL Listed, XOBA, UL 2808 |
UL Canada | UL Listed - XOBA7 |
Standard Lead Length | 8 ft (2.4m) 18 AWG |
Phase Angle | ±0.25 degrees, ±0.50 degrees below 0°C |
Output Options | 0.333 Vac, 1 V, 100 mA* |
Operating Temperature | −40°C to 80°C |
Line Frequency | 50/60 Hz |
Option 50 Hz Available | √ |
*mA output available in 250 and 600 amp Accu-CTs.
Accuracy
The accuracy specifications apply over the full operating temperature range (-30°C to 55°C) unless otherwise noted. Standard models are calibrated for optimum accuracy at 60 Hz. For use with 50 Hz services, we recommend ordering with Option 50Hz. The following accuracy specifications may vary when other CT options are specified.
Revenue Grade Accuracy
With Option C0.6, the Accu-CT is calibrated and verified to meet IEEE/ANSI C57.13-2008 class 0.6 accuracy and IEC 60044-1 class 0.5 S accuracy and each CT is shipped with a certificate of calibration. When used on 50 Hz services, Option C0.6 must be ordered with Option 50Hz.
- •Accuracy: ±0.50% from 1% to 120% of rated primary current
- •Phase angle: ±0.25 degrees (15 minutes) from 1% to 120% of rated current; ±0.50 degrees (30 minutes) below 0°C from 1% to 10% of rated current
- •IEEE C57.13 accuracy: class 0.6 from 1% to 120% of rated current
- •IEC 60044-1 accuracy: class 0.5 and 0.5 S from 1% to 120% of rated current
- •Available Models: Option C0.6 is available for all models except ACTL-0750-005
- •Note: The ACTL-0750-250 Opt C0.6 model specifications are valid only to 40°C
Electrical
- • Primary rating: 5 to 250 amps nominal, 600 Vac, 60 Hz nominal
- • Maximum continuous primary amps: varies with model and options
- • Maximum primary conductor gauge: 4/0, 250 kcmil
- • Note, the largest sizes may not fit in all cases, depending on insulation thickness.
- • Output: 333.33 mVac or 1.00 Vac (with Option 1V)
- • Output lead wires:
- • Style: Two conductor, white and black twisted pair (equivalent to about one #8 AWG 0.213″ dia.)
- • Standard length: 8 ft (2.4 m)
- • Gauge: #18 AWG
- • Type: MTW, UL 1015
- • Voltage: 600 Vac
- • Internal Burden Resistance
Mechanical
- •Width: 2.38 inches (60.4 mm)
- •Height: 2.40 inches (61.0 mm)
- •Thickness: 0.90 inches (22.9 mm)
- •Window: 0.78 inches (20.0 mm)
- •Weight: 6.1 oz (172 grams)
- •Material: PC/ABS
Miscellaneous
- •Operating temperature: -30°C to 55°C
- •UL recognized: file number E325972 (XODW2), standard IEEE/ANSI C57.13
- •cUL recognized (Canada): file number E325972 (XODW8), standard CAN/CSA 60044-1
- •CE mark: IEC 60044-1; ACTL-0750-Declaration-of-Conformity
- •RoHS
- •Assembled in USA, qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
- •Label barcode: QR Code, “Model ; SerialNum”