We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Offered with an included IrDA printer, Bacharach’s PCA3 255 Portable Combustion Analyzer Kit offers all the same features and functions as the PCA3 255 (0024-8443) Analyzer.
Check out Bacharach’s complete PCA3 Portable Combustion Analyzer Series (Click on the part numbers):
PCA3 225 (O2, CO) |
|
PCA3 235 (O2, CO, NO) |
|
PCA3 245 (O2, CO, CO High) |
|
PCA3 255 (O2, CO, SO2) |
|
PCA3 265 (O2, CO, NO, NO2) |
|
PCA3 275 (O2, CO, NO, SO2) |
|
PCA3 285 (O2, CO, NO, CO High) |
|
PCA3 225 Kit (O2, CO, Printer) |
|
PCA3 235 Kit (O2, CO, NO, Printer) |
|
PCA3 245 Kit (O2, CO, CO High, Printer) |
|
0024-8450 |
PCA3 255 Kit (O2, CO, SO2, Printer) |
PCA3 265 Kit (O2, CO, NO, NO2, Printer) |
|
PCA3 275 Kit (O2, CO, NO, SO2, Printer) |
|
PCA3 285 Kit (O2, CO, NO, CO High, Printer) |
|
PCA3 295 (O2, CO, NO2, SO2) |
|
PCA3 295 Kit (O2, CO, NO2, SO2, Printer) |
All kits include (unless otherwise noted):
- • Probe with 12 in. sample tube (approximately 6 ft. total length), water trap, particulate filter and probe stop
- • Spare filters (qty. 3)
- • Protective rubber boot
- • 4x AA batteries
- • Fyrite® User Software
- • USB cable
- • User manual
- • Hard carrying case
Reporting kit adds:
- • IrDA wireless printer
- • 4 additional AA batteries
Measurements: O2 CO (low-range, H2-compensated) CO (high-range, optional) NO (optional) NO2 (optional) SO2 (optional) Stack temperature Primary/ambient air temperature Draft/differential pressure |
0 to 20.9% 0 to 4000 ppm 4001 to 20,000 ppm 0 to 3000 ppm 0 to 500 ppm 0 to 5000 ppm -4 to 2192 °F (-20 to 1200 °C) -4 to 999 °F (-20 to 537 °C) ± 72 inH2O (± 179 mbar) |
Display |
3.5 in. color LCD w/backlight |
Power |
4x AA batteries or optional wall adapter |
Run Time |
10 hours minimum (alkaline batteries) |
Size (H x W x D) |
9.0 x 3.0 x 2.5 in. (22.9 x 7.6 x 6.3 cm) |
Weight |
2.4 lb. (1.1 kg) including batteries and probe |
Fuels [1] |
Natural gas, coal, oil 2/4/6, wood, kerosene, |
Operating Conditions |
Analyzer: 32 to 104 °F (0 to 40 °C), 15 to 90% RH Probe tip [2]: 1000 °F (538 °C) maximum, 10 inH2O |
Warm-up Time |
60 seconds |
Memory |
1000 locations (500/ea for manually-saved and |
Communications |
USB 2.0 (mini-B), IrDA |
Approvals |
CE mark, EN 50379-2 |
Warranty |
2 years (including sensors) |
[1] Depending upon combustion equation setting (North American or Siegert) – see manual for details
[2] For standard 12 in. probe, P/N 0024-3004
Products In This Series
As low as
Now $2,699.00As low as
Now $2,699.00As low as
Now $2,699.00