We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Pressure Types
Gauge, differential & compound
Available Ranges
(See Chart)
Available Accuracies
±0.06 (0/1-0/200 in. H2O), ±0.07 (0/0.25-0/0.5 in.
H2O) or 0.1% of Span
Compensated Temperature Range
20°F to 120°F
Temperature Effect
±.004% of Span per °F over compensated range
(from reference temperature range of 70° ±3°)
Repeatability
±0.01% of span (range 0/1 in. H2O or higher)
±0.02% of span (ranges below 0/1 in. H2O)
Sensitivity
±0.002% of span (typical)
Media Compatibility
Clean, dry, non-conductive, non-corrosive gas
Under/Overpressure Capability
–15 to 50 psi
Maximum Static (line) Pressure
100 psi
Process Connection
Standard: 1⁄8 NPT female
Other Options
FM Approved (for use with FM approved base unit)
CE Mark (for use with CE Mark rated base unit)