PERFORMANCE SPECIFICATIONS
Reference temperature 70°F (21°C)
Accuracy, Three Classes (% Span): ±.25 ±0.5 ±1.0
Includes non-linearity (Terminal Point Method), hysteresis,
non-repeatability, zero offset and span setting errors
Best Fit Straight Line* (BFSL): ±.20 ±.40 ±.50
Includes non-linearity hysteresis, non-repeatability errors
*Add ±.05% for ranges above 5000 psi
Stability:
±0.25% Span/year @ reference conditions
Durability: Greater than 10 million cycles
ENVIRONMENTAL SPECIFICATIONS
Temperature Limits:
Storage: –40 to +125°C (–40 to 257°F)
Process: –40 to +125°C (–40 to 257°F)
Operating: –40 to +125°C (–40 to 257°F)
Compensated*:–20 to +85°C ( –4 to 185°F)
*Consult factory for other options
Temperature Effects: –20 to +85°C (–4 to 185°F)
• 1.0% of Span for .25% Accuracy Class
• 2.0% of Span for .50% and 1.0% Accuracy Classes
Humidity Effects: No performance effects from
0 to 95% relative humidity, non-condensing,
0-100% RH with “W” enclosure.
*Consult factory
FUNCTIONAL SPECIFICATIONS
Response Time: <2ms
Pressure Ranges: Vacuum, gauge, compound and absolute
pressure from 0-5 psi through 0-10,000. Equivalent ranges
in bar available. See order guide section (reverse).
Vibration Effect:
Shock: 100g Peak, 11ms
Random: 10g RMS, 20-2000Hz
Sweep: 50-2000Hz, 5g peak
Position Effect: ±0.02% Typical
CE Mark (standard): EN 61326:1997 + A1: 1998 Annex A
Heavy Industrial Immunity (Annex A, Table A.1)
Light Industrial/Residential Emission (Table 4)
Overpressure (F.S.)*: Proof Burst
0#/vac. to 300 psi 1.5 x F.S. min. 2 x F.S.
500-10,000 psi 1.2 x F.S. 1.5 x F.S.
*For higher overpressure ratings use XK8 option.
ELECTRICAL SPECIFICATIONS
Output Signal: Supply Voltage: (unregulated)
Minimum Maximum
4-20mA* (2 Wire) 12Vdc 30Vdc
*For Intrinsically Safe see entity parameters for supply voltage
and load limits. Refer to Ashcroft A4 Installation & Maintenance
document “I&M011-10166-A4.”
Power Requirements:
See load chart page 2
Electrical Terminations: See To Order section (reverse.)
for options
Circuit Protection: Reverse polarity and mis-wire protected
Insulation Resistance (Circuit to Case): 100Mohm @ 30Vdc
PHYSICAL SPECIFICATIONS
Case: Material 304SS
Wetted Materials: 316L SS diaphragm and pressure port,
optional 17-4PH SS diaphragm and 316L SS pressure port
(see How to Order Section).
Ingress Protection Rating:
Enclosure Code Rating
Basic (S) IP65, NEMA 4X
All Welded (w/o Z/S) (W) IP67, NEMA 6
- • Oil field equipment
- • Upstream oil and gas production
- • Natural gas compression and transfer control
- • Alternative energy projects