We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Amprobe PRM-6/KIT 3-Phase Troubleshooting kit offers three mighty testing and diagnostic tools for motors and drives. The kit comes equipped with a PRM-6 Three-Phase Rotation Tester and Indicator, an AM-570 TRMS Industrial Digital Multimeter and an AMP-220 TRMS Current Clamp Meter.
The PRM-6 Motor and Phase Rotation Tester can test the motor rotation of 3-phase systems, and verify 3-phase receptacle wiring and phase sequencing with test leads. The tester also boasts wireless motor rotation detection, which senses motor rotation direction without the need for test leads. This is particularly useful for fast-running motors when the motor rotation cannot be visually determined or when the drive shaft is not visible.
The Amprobe AM-570 TRMS autoranging digital multimeter has a True-rms accuracy for measuring voltage in noisy environments, dual thermocouples for differential temperature measurements, low impedance mode to detect stray voltage, and a low pass filter to precisely measure the voltage on variable frequency drives.
The AMP-220 clamp meter has a full range of AC/DC current, AC/DC voltage and frequency measurement functions for basic electrical troubleshooting. It features a vast backlit display and is rated CAT III 600 V.
Amprobe PRM-6 Phase Sequence and Motor Rotation Tester
General Specifications | |
Operating temperature | 0°C to 40°C (32°F to 104°C) |
Operating altitude | Up to 2000 m |
Power | AAA battery (2) |
3 phase indication | LCD |
Dimensions (H x W x D) | 5.43 in x 2.56 in x 1.3 in (13.7 cm x 6.5 cm x 3.3 cm) |
Weight | .38 lb (.17 kg) including battery |
Dust/water resistance | IP 40 |
Pollution degree | 2 |
Overvoltage category | CAT IV 600 V |
Agency approvals | |
Safety | Conforms to EN 61010-1 EN 61010-031 EN 61557-1 EN 61557-7 |
EMC | Conforms to EN 61326-1 |
Electrical Specifications | |
Rotary field detection | |
Voltage range (frequency) | 40 – 700 V (16 – 60 Hz) 50 – 700 V (60 – 400 Hz) |
Nominal test current | < 3.5 mA |
Non-contract rotary field indication | |
Frequency range | 16 – 400 Hz |
Motor connection (with leads) | |
Voltage range | ≥ 1 – 700 V |
Frequency range | 2 – 400 Hz |
Nominal test current | < 3.5 mA |
Amprobe AM-570 Industrial Multimeter
FEATURE | AM-570 | Best Accuracy |
True-rms | X | |
AC Voltage | 6.000 V, 60.00 V, 600.0 V, 1000 V | +/- (1.0 % rdg + 3 LSD) @ 45 Hz to 400 Hz, 0 V to 600 V |
DC Voltage | 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V | +/- (0.5% rdg + 2 LSD) @ 6 V to 600 V ranges |
AC Current | 600.0 μA, 6000 μA, 60.00 mA, 500.0 mA, 10.00 A | ±(1.2% Rdg + 5 LSD) @ 600 μA to 6000 μA ranges, 45 Hz to 400 Hz |
DC Current | 600.0 μA, 6000 μA, 60.00 mA, 500.0 mA, 10.00 A | ±(1.0% Rdg + 2 LSD) @ 600 μA to 6000 μA ranges |
Frequency | 60.00 Hz, 600.0 Hz, 6.000 kHz, 60.00 kHz, 600.0 kHz, 6.000 MHz, 60.00 MHz | +/- (0.1% rdg + 3 LSD) |
Resistance | 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ 6.000 MΩ 60.00 MΩ | +/- (1.0% rdg + 2 LSD) @ 6 kΩ to 600 kΩ ranges |
Capacitance | 60.00 nF, 600.0 nF, 6.000 μF, 60.00 μF, 600.0 μF, 6000 μF, 60.00 mF | +/- (3.0% rdg + 5 LSD) @ 600 nF to 60 μF ranges |
Temperature | -40 ⁰F to 1832 ⁰F -40 ⁰C to 1000 ⁰C | +/- (1.0% rdg + 12) @ >104 ⁰F to 752 ⁰F +/- (1.0% rdg + 8) @ >40 ⁰C to 400 ⁰C |
Number of temperature inputs | Dual Thermocouple | |
Duty cycle | 10.00% to 90.00% | +/- (1.2% rdg + 30 LSD) @ 5 Hz to 2 kHz |
Amprobe AMP-220 600A AC/DC TRMS Clamp Meter
Model | AMP-210 | AMP-220 |
| AC Clamp Meter | AC/DC Clamp Meter |
Safety Rating | CAT III 600 V | CAT III 600 V |
Jaw Opening | 1.18 in (30 mm) | 1.37 in (35 mm) |
AC Voltage | Range: 0 to 600.0 V | |
DC Voltage | Range: 0 to 600.0 V | |
AC+DC Voltage |
– | Range: 0 to 600.0 V |
AC Current | Range: 0 to 600.0 A | |
DC Current | – | Range: 0 to 600.0 A |
AC+DC Current |
– | Range: 0 to 600.0 A |
Precise Low | Range: 0 to 60.00 A | |
Precise Low | | Range: 0 to 60.00 A |
|
| Range: 0 to 60.00 A |
Frequency | Range: 5.00 to 999.9 Hz | |
Resistance | Range: 0.0 to 60.00 kΩ | |
Capacitance | Range: 0.0 to 2500 µF | |
Continuity | ON ≤ 10 Ω | |
Non-Contact | | |
True-RMS | • | • |
Low Pass Filter | • | • |
Autoranging | • | • |
Relative Zero | • | • |
MAX/MIN/AVG | • | • |
Diode Test | • | • |
Data Hold | • | • |
Backlight | • | • |
Auto Power Off | • | • |
Model | AMP-210 | AMP-220 |
Display | 3-5/6 digits 6000 counts | 3-5/6 digits 6000 counts |
Polarity | Automatic | Automatic |
Update Rate | 5 per second nominal | 5 per second nominal |
Operating | | |
Relative Humidity | 80% at 30°C, 50% at 40°C | 80% at 30°C, 50% at 40°C |
Operating Altitude | 0 to 2000 m | 0 to 2000 m |
Pollution Degree | 2 | 2 |
Storage | -4 to 140°F (-20°C to 60°C), | -4 to 140°F (-20°C to 60°C), |
Temperature | Nominal 0.15 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 40°C) | Nominal 0.15 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 40°C) |
Battery | Two AAA 1.5 V battery | Two AAA 1.5 V battery |
EMC | Meets EN 61326-1:2006 | Meets EN 61326-1:2006 |
Safety | UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 | UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 |
Certification | UL (c/us) and CE | UL (c/us) and CE |
Dimensions | 8.62 x 3.03 x 1.46 in | 8.82 x 3.03 x 1.46 in |
Weight: | 208 g (0.46 lb) | 254 g (0.56 lb) |