Amprobe PRM-6/KIT 3-Phase Motors Troubleshooting Kit w/ Multimeter and Clamp Meter

SKU
PRM-6/KIT
Manufacturer:
Amprobe
Amprobe

Key Features:

Amprobe PRM-6 Phase Sequence and Motor Rotation Tester

  • 3-phase wire sequence indication
  • Error displays (missing phase, one input connected to neutral or PE)
  • Non-contact, wireless motor rotation detection on running motors
  • Indicates motor rotation of disconnected motors when spinning the shaft by hand or other means
  • 3-phase to phase voltage up to 700 V
  • Clear backlit LCD display
  • Durable rubber casing for 3 ft. (1 m) drop proof protection
  • Safety: CAT IV 600 V

Amprobe AM-570 Industrial Multimeter

  • True-rms technology improves accuracy in electrically noisy environments
  • Measures AC/DC Voltage up to 1000V, AC/DC current, resistance, frequency, capacitance, temperature, and duty cycle
  • Low Z mode detects stray voltages
  • Low pass filter accurately measures voltage on variable frequency drives
  • Peak hold (crest) captures and holds the peak value of a voltage or current surge
  • Non-contact voltage detection enhances safety
  • Audible continuity quickly identifies shorts and opens
  • Diode test to verify diode polarity
  • Data hold freezes the reading on the display for further analysis
  • MIN/MAX recording records min/max measurements over time to show voltage fluctuations
  • Relative zero mode displays the difference between the actual reading and a stored reference value and may be used with any function or range
  • Warning alerts against improper test leads connection
  • Combines user friendly features such as, auto power-off to conserve battery life, low battery warning, a “third hand test probe holder, built-in test leads storage, a built-in flashlight, and a Velcro strap to hang the meter
  • Auto and manual-ranging delivers maximum flexibility
  • Dual reading backlit LCD display with analog bar graph makes it easy to view results
  • CAT IV 600V/CAT III 1000V safety rated for high voltage environments

Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

  • Measures AC/DC Current to 600 A and AC/DC Voltage to 600 V
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Capacitance measurement, continuity beeper and diode test
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Offers data hold and relative zero for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • Backlit display for easy measurement viewing in bright and dim environments
  • Accommodates conductors up to 1.37 in (35mm)
  • Includes test leads, batteries (installed), carrying case, and user manual
  • CAT III 600 V safety rated
$719.99

Secured and trusted checkout with

The Amprobe PRM-6/KIT 3-Phase Troubleshooting kit offers three mighty testing and diagnostic tools for motors and drives. The kit comes equipped with a PRM-6 Three-Phase Rotation Tester and Indicator, an AM-570 TRMS Industrial Digital Multimeter and an AMP-220 TRMS Current Clamp Meter.

 

The PRM-6 Motor and Phase Rotation Tester can test the motor rotation of 3-phase systems, and verify 3-phase receptacle wiring and phase sequencing with test leads. The tester also boasts wireless motor rotation detection, which senses motor rotation direction without the need for test leads. This is particularly useful for fast-running motors when the motor rotation cannot be visually determined or when the drive shaft is not visible.

 

The Amprobe AM-570 TRMS autoranging digital multimeter has a True-rms accuracy for measuring voltage in noisy environments, dual thermocouples for differential temperature measurements, low impedance mode to detect stray voltage, and a low pass filter to precisely measure the voltage on variable frequency drives.

 

The AMP-220 clamp meter has a full range of AC/DC current, AC/DC voltage and frequency measurement functions for basic electrical troubleshooting. It features a vast backlit display and is rated CAT III 600 V.

 

 

Amprobe PRM-6 Phase Sequence and Motor Rotation Tester

General Specifications
Operating temperature0°C to 40°C (32°F to 104°C)
Operating altitudeUp to 2000 m
PowerAAA battery (2)
3 phase indicationLCD
Dimensions (H x W x D)5.43 in x 2.56 in x 1.3 in (13.7 cm x 6.5 cm x 3.3 cm)
Weight.38 lb (.17 kg) including battery
Dust/water resistanceIP 40
Pollution degree2
Overvoltage categoryCAT IV 600 V
Agency approvals
SafetyConforms to EN 61010-1
EN 61010-031
EN 61557-1
EN 61557-7
EMCConforms to EN 61326-1

 

Electrical Specifications
Rotary field detection
Voltage range (frequency)40 – 700 V (16 – 60 Hz)
50 – 700 V (60 – 400 Hz)
Nominal test current< 3.5 mA
Non-contract rotary field indication
Frequency range16 – 400 Hz
Motor connection (with leads)
Voltage range≥ 1 – 700 V
Frequency range2 – 400 Hz
Nominal test current< 3.5 mA

 

 Amprobe AM-570 Industrial Multimeter

FEATUREAM-570Best Accuracy
True-rmsX 
AC Voltage6.000 V, 60.00 V, 600.0 V, 1000 V+/- (1.0 % rdg + 3 LSD)
@ 45 Hz to 400 Hz, 0 V to 600 V
DC Voltage600.0 mV, 6.000 V, 60.00 V,
600.0 V, 1000 V
+/- (0.5% rdg + 2 LSD) @ 6 V to 600 V ranges
AC Current600.0 μA, 6000 μA,
60.00 mA, 500.0 mA,
10.00 A
±(1.2% Rdg + 5 LSD)
@ 600 μA to 6000 μA ranges,
45 Hz to 400 Hz
DC Current600.0 μA, 6000 μA,
60.00 mA, 500.0 mA,
10.00 A
±(1.0% Rdg + 2 LSD)
@ 600 μA to 6000 μA ranges
Frequency60.00 Hz, 600.0 Hz,
6.000 kHz, 60.00 kHz, 600.0 kHz,
6.000 MHz, 60.00 MHz
+/- (0.1% rdg + 3 LSD)
Resistance600.0 Ω,
6.000 kΩ, 60.00 kΩ, 600.0 kΩ
6.000 MΩ 60.00 MΩ
+/- (1.0% rdg + 2 LSD)
@ 6 kΩ to 600 kΩ ranges
Capacitance60.00 nF, 600.0 nF,
6.000 μF, 60.00 μF, 600.0 μF, 6000 μF,
60.00 mF
+/- (3.0% rdg + 5 LSD)
@ 600 nF to 60 μF ranges
Temperature-40 ⁰F to 1832 ⁰F
-40 ⁰C to 1000 ⁰C
+/- (1.0% rdg + 12) @ >104 ⁰F to 752 ⁰F
+/- (1.0% rdg + 8) @ >40 ⁰C to 400 ⁰C
Number of temperature inputsDual Thermocouple 
Duty cycle10.00% to 90.00%+/- (1.2% rdg + 30 LSD) @ 5 Hz to 2 kHz

 

Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

 Model

AMP-210

AMP-220

 

AC Clamp Meter
Electrical

AC/DC Clamp Meter
Electrical

 Safety Rating

CAT III 600 V

CAT III 600 V

 Jaw Opening

1.18 in (30 mm)

1.37 in (35 mm)

 AC Voltage
 (True-RMS)

 Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)

 DC Voltage

Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD

 

 AC+DC Voltage

 

Range: 0 to 600.0 V
Accuracy: 1.2% ±7LSD (DC,
50 to 60 Hz)

 AC Current
 (True-RMS)

Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)

 DC Current

Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD

 

 AC+DC Current

 

Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)

  Precise Low
 Current AC

 Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)

 Precise Low
 Current DC

 

Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD

 
 Precise Low

 Current AC+DC



 Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)

 

 Frequency

Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)

 

 Resistance

Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD

 

 Capacitance

Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD

 Continuity
 Beeper

ON ≤ 10 Ω
OFF > 250 Ω

 Non-Contact
 Voltage

 
20 to 440 V, 50/60 Hz

 True-RMS

 Low Pass Filter

 Autoranging

 Relative Zero

 MAX/MIN/AVG

 Diode Test

 Data Hold

 Backlight

 Auto Power Off

 

 Model

AMP-210

AMP-220

 Display

3-5/6 digits 6000 counts

3-5/6 digits 6000 counts

 Polarity

Automatic

Automatic

 Update Rate

 5 per second nominal

 5 per second nominal

 Operating
 Temperature

 
32 to 104°F (0 to 40°C)

 
32 to 104°F (0 to 40°C)

 Relative Humidity

 80% at 30°C, 50% at 40°C

 80% at 30°C, 50% at 40°C

 Operating Altitude

0 to 2000 m

 0 to 2000 m

 Pollution Degree

2

2

 Storage
 Temperature

 -4 to 140°F (-20°C to 60°C),
< 80% RH

 -4 to 140°F (-20°C to 60°C),
< 80% RH

 Temperature
 Coefficient

 Nominal 0.15 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 40°C)

 Nominal 0.15 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 40°C)

 Battery

 Two AAA 1.5 V battery

 Two AAA 1.5 V battery

 EMC

 Meets EN 61326-1:2006

Meets EN 61326-1:2006

 

 Safety
 Compliance

 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1

 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1

 Certification

 UL (c/us) and CE

 UL (c/us) and CE

 Dimensions
 (L x W x H):

8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)

 8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)

 Weight:

208 g (0.46 lb)

254 g (0.56 lb)

 

 

Write Your Own Review