Ametek Jofra HPC-600 Automatic Pressure Calibrator - DISCONTINUED

SKU
HPC600
Manufacturer:
Ametek
Ametek

Key Features:

This Product is DISCONTINUED
Please see the Crystal Engineering HPC40 Series as a Replacement

  • Pressure ranges
    - HPC600-2A 0 to 30 PSIA (2 Bar Abs)
    - HPC600-2C Vacuum to 30 PSIG (2 Bar)
    - HPC600-10A 0 to 150 PSIA (10 Bar Abs)
    - HPC600-10C Vacuum to 150 PSIG (10 Bar)
    - HPC600-020C Vacuum to 300 PSIG (20 Bar)
  • High accuracy ±0.020% of reading +0.015% F.S.
  • True field calibration Fully temperature compensated
  • Unique built-in electrical pump HPC600 has a built-in automatic pressure system, based on an electrical pressure and vacuum pump.
  • Complete 4-20 mA loop calibrator HPC600 features a complete mA loop calibrator with all common loop calibrator features: measure, source & sink mA, and supply 24 volt for transmitters.
  • Comprehensive set of features Wide selection of useful functions and features. Damping, leak test, error calculation, min/max, switch test, etc.
  • Thermometer High accuracy thermometer, Pt100 sensor.
  • External pressure modules More tham 60 different pressure modules, accuracy up to 0.01% F.S.
Call For Price

Secured and trusted checkout with

     The JOFRA HPC600 calibrator features a built-in electrical pump system for generation of pressure and vacuum by a touch of a single key! Besides the unique pump system, the HPC600 offers a complete choice of features and functions making it an ideal tool and calibrator. A true multifunction solution designed to save time, money and space… HPC600 is a pressure indicator, a pressure calibrator, a complete mA loop calibrator, including 24 volt supply, a voltmeter, a thermometer and a pressure/vacuum generator. All supplied in a ruggedized housing with an easy intuitive operating system in the palm of your hand.

    The HPC600 is delivered as a ready-to-test system, complete with hose, fittings, and a padded soft case, equipped to meet any need for pressure calibration. An international traceable calibration certificate, including vacuum and electrical parameters is part of the standard delivery to make the HPC600 a truly ready-to-use solution. The HPC600 can be used in a very wide range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems. A time and money saver! HPC600 is a multifunction tool designed to meet high accuracy pressurecalibration applications.

     The HPC600 offers features such as a user configurable information display, 15 different pressure units, transmitter supply, mA input/output, % error calculation, voltage measurement, serial communication, and an external pressure module capability. The accuracy of the HPC600 calibrator is specified in % of reading to ensure an even better accuracy and more applicable pressure range. The HPC600 is temperature compensated from -10 to 50 ºC / 14 to 122 ºF for on-site operations. It is a truly superior pressure calibrator for laboratory and field use, bringing laboratory accuracy into the field. The JOFRA APM series of pressure modules extends the application base of the HPC calibrators by allowing calibrations in additional ranges. The APM modules are compatible with several other JOFRA calibrators.

Pressure; gauge / compound ranges
bar..........................................................-0.82 to 2, 10 or 20
psi........................................................-12 to 30, 150 or 300
Pressure; absolute ranges
bara................................................................. 0.2 to 2 or 10
psia................................................................. 3 to 30 or 150
Engineering units (built-in)
User selectable......................................................... 15 units
(bar, mbar, MPa, kPa, inHg@0°C, mmHg@0°C, kg/cm2, mmH2O@4˚C,
mmH2O@20˚C, psi, inH2O@4˚C, inH2O@20˚C, inH2O@60˚F, cmH2O@4˚C,
cmH2O@20˚C)
Pressure accuracy reference temp. (18 to 28°C / 65 to 82°F)
All pressure ranges................±0.020% RDG + 0.015% F.S.
Vacuum........................................................... ±0.025% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range. Requiring frequently zeroing
(gauge/compound) or entering of reference pressure (absolute).
Pressure accuracy ambient temp. (-10 to 50°C / 14 to 122°F)
All pressure ranges................±0.030% RDG + 0.015% F.S.
Vacuum........................................................... ±0.035% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range. Requiring frequently zeroing
(gauge/compound) or entering of reference pressure (absolute).
Display
LCD...................................................... Graphical (with light)
Display resolution...................................................... 5 digits
Display update....................................... 3 times per second
RS232 communication interface
Connector.................................................................... LEMO
Serial............ 0-5 VDC, 9600 baud, 8 data, no parity, 1 stop
Protocol....................................... ASCII command language
Input / output (18 to 28°C / 65 to 82°F)
mA range, input, output and sink....................... 0 to 24 mA
mA accuracy, input............................±0.015% RDG + 2 μA
mA accuracy, output/sink..................±0.015% RDG + 2 μA
Transmitter supply.........................................24 VDC ±10%
Voltage measurement....................................... 0 to 30 VDC
Voltage accuracy................................ ±0.015% RDG + 2mV
RTD range (ohms).............................................84 to 140 Ω
RTC accuracy ................................ ±0.015% RDG + 0.02 Ω
RTD range (temp.)......................-40 to 155ºC / -40 to 311ºF
RTD accuracy @ 0ºC/32ºF (temp.)...............±0.10ºC/0.18ºF
HART® resistor............................................................ 250 Ω
Peak hold capture.........................................50 milliseconds
Switch test input...................................................5V (<1mA)
Temperature effect outside 18 to 28°C / 65 to 82°F ±0.001% F.S./°C.
Media compatibility
Dry, clean, non corrosive gasses
Environmental
Operating temperature................. -10 to 50°C / 14 to 122°F
Storage temperature.....................-20 to 60°C / -4 to 140°F
Ingress protection rating................................................ IP56
Pressure connection
All calibrators .................. 1/8” BSP/NPT female (combined)
Adapters to 1/4” NPT female and 1/4” BSP female are included as standard.
Pressure overload
Overload alarm.......... “OL” in display at approx. +20% F.S.
Power supply
Battery................................................. 8 x 1.5 VDC Alkaline
Battery type.....................................AA, LR6, MN1500, AM3
Battery lifetime...More than 300 pump cycles to 10 bar/150 psi
Low battery indicator...................................................... Yes
Instrument dimensions (LxWxH)
Calibrator................................ 203x102x61 mm / 8x4x2.4 in
HPC600 weight (incl. battery).......................920 g / 32.5 oz
Calibrator, shipping........... 560x350x180 mm/ 22x13.8x7 in
Calibrator weight, shipping...........................3,2 kg / 113 oz
Miscellaneous
Compliance: EN 61326 : 2006 & CISPR 11, Edition 5.0 -
2009 Class “B”

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account