Ametek JOFRA HPC550Ex Family Handheld Pressure Calibrator, Single Range - DISCONTINUED

SKU
HPC-550Ex
Manufacturer:
Ametek
Ametek

Key Features:

This Product is DISCONTINUED
Please see the Crystal Engineering IS33 as a Replacement

  • Ex Safety Certifications
  • Wide pressure range 25 mbar to 700 bar FS (0.35 to 10,000 psi)
  • High accuracy ±0.025% of reading +0.01% F.S.
  • True field calibrator Fully temperature compensated
  • Single or dual sensor versions Chose between HPC550Ex single sensor calibrator, or HPC552Ex dual sensor calibrator. A HPC552Ex might be an alternative to two separate calibrators, saving investment and cost of ownership
  • Full set of intelligent features Wide selection of useful functions and features. Damping, leak test, % error calculation, min/max, switch test, etc.
  • Thermometer High accuracy thermometer, Pt100 sensor.
  • Intrinsically Safety - Apparatus - IECEx and EU Ex standards JOFRA HPC550/552Ex are intended for use in explosively hazardous areas and designed to prevent ignition by electrical, sparking or heating effects.
Call For Price

Secured and trusted checkout with

     JOFRA HPC550/552Ex calibrators feature deadweight tester accuracy in a modern digital package. The HPC550/552Ex can be used in a very broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems. Including potential hazardous areas in Oil, Gas and Chemical industries.

     The HPC550/552Ex series has been designed to meet high accuracy pressure calibration applications and faciliate your tasks. HPC550/552Ex offers features such as user configurable information display, 15 different pressure units, transmitter supply, mA input, % error calculation, voltage measurement, serial communication, and external pressure module capability. The accuracy of the HPC550/552Ex calibrators is specified in % of reading to ensure an even better accuracy and wider applicable pressure range. The HPC is temperature compensated from 0 to 45ºC/32 to 113ºF for on-site operation. It is a truly superior pressure calibrator for laboratory and field use, bringing laboratory accuracy into the field.

Pressure: compound ranges
bar.................................................................. -0.96 to 1 or 2
bar..........................................................-0.82 to 7, 20 or 35
psi.................................................................. -14 to 15 or 30
psi......................................................-12 to 100, 300 or 500
Pressure: gauge ranges
bar..........................................................70, 200, 350 or 700
psi...........................................1,000, 3,000, 5,000 or 10,000
Pressure: absolute ranges
bar.............................................................. 0.025 to 1.1 or 2
bar................................................................. 0.07 to 7 or 20
psi................................................................ 0.35 to 16 or 30
psi................................................................. 1 to 100 or 300
Pressure: differential ranges (HPC550Ex only)
mbar.......................................................... ±25, ±70 or ±350
psi................................................................. ±0.35, ±1 or ±5
Engineering units (built-in)
User selectable......................................................... 15 units
(bar, mbar, MPa, kPa, inHg@0°C, mmHg@0°C, kg/cm2, mmH2O@4˚C,
mmH2O@20˚C, psi, inH2O@4˚C, inH2O@20˚C, inH2O@60˚F, cmH2O@4˚C,
cmH2O@20˚C)
Pressure accuracy ambient temp. (18 to 28°C/65 to 82°F)
±25 mbar / 0.35 psi........................................... ±0.10% F.S.
±70, 350 mbar / 1, 5 psi................................... ±0.05% F.S.
700 bar / 10k psi................... ±0.025% RDG + 0.015% F.S.
All other pressure ranges........ ±0.025% RDG + 0.01% F.S.
Vacuum........................................................... ±0.025% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measurements
or enter the reference pressure for absolute measurements.
Pressure accuracy ambient temp. (0 to 45°C/32 to 113°F)
±25 mbar / 0.35 psi........................................... ±0.15% F.S.
±70, 350 mbar / 1, 5 psi................................... ±0.10% F.S.
700 bar / 10k psi..................... ±0.04% RDG + 0.015% F.S.
All other pressure ranges.......... ±0.04% RDG + 0.01% F.S.
Vacuum............................................................. ±0.05% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Temperature effect -10 to 0°C / 14 to 32°F ±0.005% F.S./°C.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measurements
or enter the reference pressure for absolute measurements.
Display
LCD...................................................... Graphical (with light)
Display resolution...................................................... 5 digits
Display update....................................... 3 times per second
Ex Certifications
ATEX...................... II 2 Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.........................................................KEMA 10 ATEX 1068 X
IECEx........................... Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.............................................................. IECEx CSA 10.0013
Input / output (18 to 28°C/65 to 82°F)
mA range............................................................. 0 to 24 mA
mA accuracy......................................±0.015% RDG + 2 μA
RTD range (ohms).............................................. 84 to 140 Ω
RTD accuracy................................. ±0.015% RDG + 0.02 Ω
RTD range (temperature).................. -40 to 155ºC/-40 to 311ºF
RTD accuracy @ 0ºC/32ºF (temperature).........±0.10ºC/0.18ºF
HART® resistor............................................................ 250 Ω
Peak hold capture.........................................50 milliseconds
Switch test input...................................................5V (<1mA)
Temperature effect outside 18 to 28°C/65 to 82°F ±0.001% F.S./°C.
Media compatibility
Nickel plated brass and 316 stainless steel
Environmental
Operating temperature................... -10 to 45°C/14 to 122°F
Storage temperature.......................-20 to 60°C/-4 to 140°F
Ingress protection rating................................................ IP54
Pressure connection
All calibrators ............................................. 1/8” BSP female
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
Pressure overload
Overload alarm.......... “OL” in display at approx. +20% F.S.
Power supply
Battery................................................. 4 x 1.5 VDC Alkaline
Battery type.....................................AA, LR6, MN1500, AM3
Battery lifetime....................... Typically more than 35 hours
Low battery indicator...................................................... Yes
Instrument dimensions (LxWxH)
Calibrator............................ 201x99x50 mm / 7.9x3.9x2.0 in
HPC550 weight (incl. battery).......................635 g / 22.4 oz
HPC552 weight (incl. battery).......................665 g / 23.5 oz
Calibrator, shipping........... 243x180x80 mm/ 9.6x7.1x3.1 in
Calibrator weight, shipping.......................... 1.1 kg / 39.5 oz
Miscellaneous
Compliance: EN 60079-0 : 2009, EN 600079-11 : 2007 &
CISPR 11, Edition 5.0 - 2009 Class “B”