AEMC Model SR701 AC Current Probe (1000A / 1mA/A / Jack)

SKU
2116.29
Manufacturer:
AEMC
AEMC

Key Features:

  • Measurement range of 100mA to 1200AAC
  • Large jaw opening accommodates conductors up to two 500kcmil
  • Improved ergonomic design and easy operation
  • High content nickel metal core
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
Product Options:
$349.00

Secured and trusted checkout with

The SR701 is a general purpose 1000AAC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The SR701 has jack output terminations that accept 4mm banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift and wide frequency response are important.
MODELSR701*
ELECTRICAL
Nominal Range1000A
Measurement Range1mA to 1200A
Transformation Ratio1000:1
Output Signal1mAac/Aac
(1Aac @ 1000A)

Accuracy (1000A Range)

1mA to 100mA

 

≤3% of Reading ± 5mA

0.1 to 1A≤2% of Reading ± 3mA
1 to 10A<1% of Reading
10 to 100A≤0.5% of Reading
100 to 1200A≤0.3% of Reading

Phase Shift (1000A Range)

1 to 10A

 

≤2°

10 to 100A≤1°
100 to 1200A≤0.7°
Overload1200A for 40 min ON,
20 min OFF
Frequency Range30Hz to 5kHz;
current derating
above 1kHz using
the formula:
1000A x 1F (in kHz)
Load Impedance5Ω max
Working/Common
Mode Voltage
600Vrms CAT III
Output TerminationJack
MECHANICAL
Operating Temperature-14° to 122°F (-10° to 50°C)
Storage Temperature-4° to 158°F (-20° to 70°C)
Operating Relative
Humidity
0 to 85% @ 35°C
Jaw Opening2.25” (57mm) max
Maximum Conductor Size2.05” (52mm)
Maximum Bus Bar SizeOne 1.95 x 0.19” (50 x 5mm)
Dimensions4.37 x 8.50 x 1.77” (111 x 216 x 45mm)
Weight1.21 lbs (550g)
Polycarbonate MaterialHandles: Polycarbonate + ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
ElectricalEN 61010-2-032
UL ApprovalYes – Canada and United States
Double InsulationYes
CE MarkYes

Note: Reference conditions: 23 ± 3°K, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered. Load impedance 5Ω.
*Diode Protection for open secondary (Output)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Power quality measuring
  • Large industrial loads
  • Measuring around cable bundles
  • Power load monitoring
  • Waveform analysis