AEMC Model MN291 AC Current Probe (240A / 100mVDC/A / Lead)

SKU
2115.84
Manufacturer:
AEMC
AEMC

Key Features:

  • Small, compact size
  • Large jaw opening accommodated conductors up to 250kcmil
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • Conforms to EN 61010, 600V CAT III
Product Options:
$225.00

Secured and trusted checkout with

The MN291 is a general purpose AC current probe with voltage output. It is designed for use with DMMs or with measuring instruments with voltage inputs. These probes permit the measurement or recording of current with instruments without current ranges. The voltage output is proportional to the current measured (through the jaws). The MN291 offers a VDC output of 100mVDC per AAC and may be used with loggers or other instruments with DC voltage input. The MN291 has integral 5 ft (1.5m) leads terminated by shrouded banana plugs.
ELECTRICAL
Nominal Range200A
Measurement Range0.5 to 240A
Transformation RatioDC Voltage output
Output Signal100mV/ADC/AAC
Accuracy (200A Range) 
0.5 to 10A3.0% of Reading ± 50mV
10 to 40A2.5% of Reading ± 50mV
40 to 100A2.0% of Reading ± 50mV
100 to 240A2.0% of Reading
Phase Shift (200A Range)Not Applicable
Overload240A for 10 min ON, 30 min OFF
Frequency Range40 to 10kHz
Limit Operating
Conditions
200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333F), F in kHz
Crest Factor3 @ 200Arms with an error (due to CF) of 4%
Working/Common
Mode Voltage
600Vrms
Output Termination5 ft Lead
MECHANICAL
Operating Temperature14° to 131°F (-10° to 55°C)
Storage Temperature-40° to 158°F (-40° to 70°C)
Operating Relative
Humidity
10 to 35°C 85% RH (without roll-off above 35°C)
Jaw Opening0.83" (21mm)
Maximum Conductor Size0.78" (20mm)
Dimensions5.47 x 2.00 x 1.18" (139 x 51 x 30mm)
Weight6.5 oz (180g)
Polycarbonate MaterialPolycarbonate with fiberglass charge, UL94 V0
SAFETY
ElectricalEN 61010-2-32
UL ApprovalYes – Canada and United States
Double InsulationYes
CE MarkYes

 

Note: Reference conditions: 20 to 26°C, 20 to 75% RH, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance >1Ω

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Measuring in breaker panels
  • Industrial loads
  • HVAC
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring