AEMC Model MN255 AC Current Probe (24A-100mV/A / 240A-10mV/A / Lead)

SKU
2115.81
Manufacturer:
AEMC
AEMC

Key Features:

  • Small, compact size
  • Large jaw opening accommodated conductors up to 250kcmil
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • Conforms to EN 61010, 600V CAT III
Product Options:
$225.00

Secured and trusted checkout with

The MN255 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and combine two switch-selectable ranges of 20A and 200A, thus permitting accurate measurements at low and high levels. The MN255 has integral 5 ft (1.5m) leads terminated by shrouded banana plugs.
ELECTRICAL
Nominal Range20A & 200A
Measurement Range0.5 to 240A
Transformation RatioVoltage output
Output Signal20A: 100mV/A,
200A: 10mV/A
Accuracy (20A Range)1.0% of Reading ± 50mV
Phase Shift (20A Range)Not Specified
Overload (20A Range)24A for 10 min ON, 30 min OFF
Accuracy (200A Range) 
0.5 to 10A3.0% of Reading ± 5mV
10 to 40A2.5% of Reading ± 5mV
40 to 100A2.0% of Reading ± 5mV
100 to 240A1.0% of Reading ± 5mV

Phase Shift (200A Range)

0.5 to 10A
10 to 40A
40 to 100A
100 to 240A

 

Not Specified
≤5.0°
≤3.0°
≤2.5°

Overload (200A Range)
240A for 10 min ON, 30 min OFF
Frequency Range40 to 10kHz
Limit Operating
Conditions
200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333F), F in kHz
Crest Factor3 @ 200Arms with an error (due to CF) of 4%
Working/Common
Mode Voltage
600Vrms
Output Termination5 ft Lead
MECHANICAL
Operating Temperature14° to 131°F (-10° to 55°C)
Storage Temperature-40° to 158°F (-40° to 70°C)
Operating Relative
Humidity
10 to 35°C 85% RH (without roll-off above 35°C)
Jaw Opening0.83" (21mm)
Maximum Conductor Size0.78" (20mm)
Dimensions5.47 x 2.00 x 1.18" (139 x 51 x 30mm)
Weight6.5 oz (180g)
Polycarbonate MaterialPolycarbonate with fiberglass charge, UL94 V0
SAFETY
ElectricalEN 61010-2-32
UL ApprovalYes – Canada and United States
Double InsulationYes
CE MarkYes

 

Note: Reference conditions: 20 to 26°C, 20 to 75% RH, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance >1Ω

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Measuring in breaker panels
  • Industrial loads
  • HVAC
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring