AEMC Model MN01 AC Current Probe (150A / 1mA/A / Lead)

SKU
2129.17
Manufacturer:
AEMC
AEMC

Key Features:

  • Small, compact size
  • Measurement range of 2 to 150AAC
  • Jaw opening accommodates conductors up to 0.39" diameter
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • 40Hz to 10kHz response
  • 1mAAC/AAC output signals
  • Designed to EN 61010, 600V CAT III safety standard
Product Options:
$95.00

Secured and trusted checkout with

MN01 is the ideal complement for any multimeter to measure AC currents in low-power secondary or industrial applications. If there is a current in the conductor clamped, the Model MN01 is protected against over-voltages during disconnection from the measurement instrument.
ELECTRICAL
Range150A
Measurement Range2A to 150A
Accuracy in %≤ 2.5% + 0.15A (1Ω load)
≤ 3% + 0.15A (10Ω load)
Phase ShiftNot specified
Output Signal1mAac/Aac (1000/1)
(150mA at 150A)
Load Impedance≤10Ω
Maximum Currents1 < 150A permanent from 48Hz to 500Hz
Influence of Temperature≤ 0.2% per 10K
Influence of Adjacent
Conductor
≤ 2mA/A at 50Hz
Influence of Adjacent
Conductor Position in Jaws
≤ 0.1% at 50/60Hz
Influence of Frequency≤ 2% from 65Hz to 500Hz
Maximum Output Voltage
(secondary open)
30V
MECHANICAL
Operating Temperature14° to 122°F (-10° to +50°C)
Storage Temperature-40° to 176°F (-40° to 80°C)
Operating Relative
Humidity
0 to 85% RH decreasing linearly above 35°C
Operating Altitude0 to 2000m
Casing Protection Rating
(leak-proofing)
IP40(2) (EN 60529 Ed. 1995)
Fall Height4.92 ft (1.5m) (IEC 68-2-32)
Shock Protection3.52 oz (100g)/6ms/half-period (IEC 68-2-27)
Self-extinguishing Capabilitycasing UL94 V2
Vibration ResistanceIEC 68-2-6
Dimensions4.43 x 1.48 x 1.02" (112.5 x 37.5 x 26mm)
Weightapprox. 6.35 oz (180g)
SAFETY
ElectricalEN 61010-1, 600V CAT III, Pollution Degree 2
Double InsulationYes
CE MarkYes

 

(1) Conditions of reference: 23°C ± 3°K, 20 to 75% RH, sinusoidal signal with frequency of 48 to 500Hz, distortion factor < 1% with no DC component, external DC magnetic field < 40A/m, no external AC magnetic field, no external conductor with circulating current, conductor centered for measurement, measurement instrument load impedance ≥ 1MΩ (10A calibre) & ≥ 10kΩ (100A calibre).
(2) With clamp closed.

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Measuring in breaker panels
  • Industrial loads
  • HVAC
  • Residential and commercial sites
  • Data logging/recording

Products In This Series

As low as

Now $225.00

As low as

Now $135.00