We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
AEMC’s MH60 portable 100Arms current probe with an insulated BNC output cable precisely measures AC or DC current waveforms. It is equipped with proportional mV output for direct readings on oscilloscopes from DC to 1MHz at 3dB. Users can power the probe by either a rechargeable NIMH battery or from a 5 V USB power adapter.
Maximum Conductor Size | 1.02" (26mm) |
Current Range | 100AAC/DC |
Measurement Range | 0.5A to 100AAC/DC |
Output | 10mV/A |
Lead Length | 6.5ft (1.9m) |
Output Termination | BNC connector |
Accuracy (Typical) | 0.5 to 64A: ±1.15% ±0.1mV 64 to 90A: ±4% 90 to 100Arms: ±5% |
Phase Shift at 50Hz | ±1° |
Bandwidth with Filter | 1MHz @ -3dB, 30kHz @ -3dB, 3kHz @ -3dB |
Frequency Limitation | 100Arms at 45kHz continuously |
Power Source | 1.2V NIMH AAA rechargeable or 5Vdc power adaptor by female type B micro USB |
Battery Life | 7 to 8 hours continuous use |
Compatibility | Any oscilloscopes with BNC input |
Dimensions (H x W x D) | 5.43 x 1.93 x 1.1” (138 x 49 x 28mm) |
Weight | 7.04 oz (200g) |
Operating Temperature | 14° to +122°F (-10° to +55°C); 10 to 85% RH |
Storage Temperature with Battery | -4° to +122°F (-20° to +50°C); 10 to 85% RH |
Pollution Degree | 2 |
Protection | IK 04, IP40 (jaws closed), IP30 (jaws open) |
EMC | EN 61326-1 |
Safety Compliance | EN 61010-2-032, 300V CAT III CE |
Write Your Own Review
- Measuring in breaker panels
- Industrial loads
- HVAC
- Residential and commercial sites
- Data logging/recording
- General AC current measurements
- Power measurement applications