Additel ADT760-MA-02 Automatic Handheld Pressure Calibrator (0.02%FS Accuracy)

SKU
ADT760-MA-02
Manufacturer:
Additel
Additel

Key Features:

  • Max Pressure Range -12.5 to 300 psig
  • Fully automatic calibrator with built-in pump and controller
  • Switchable internal pressure modules for expandable ranges
  • Accuracy (1 year) of 0.02%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • Optional HART communications
  • Optional data logging and task documenting
  • USB and Wi-Fi communication
Product Options:
$10,990.00

Secured and trusted checkout with

The Additel ADT760-MA-02 is a handheld pressure calibrator that generates and controls pressure from vacuum pressures up to 300 psig (20 bar.g). The ADT760-MA-02 is equipped with a built-in barometric reference and has an accuracy of 0.02% full span.

Pressure Specification
 760-LLP760-D760-MA
Max Pressure Range±30 inH2O
(75 mbar)
-12.5 to 35 psi
(-0.86 to 2.5 bar)
-12.5 to 300 psig
(-0.86 to 20 bar.g)
Accuracy0.05%FS[1]0.02%FS[1]0.02%FS[1][3]
Stability0.005%FS[2]0.005%FS[2]0.005%FS[2]
Pressure TypeDifferential, GaugeDifferential, GaugeGauge, Absolute
Over Range Indication120%
Resolution6 digits
Measurement UnitsPa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, mH2O@68°F, inH2O@20°C, kgf/cm2, mtorr, torr, lb/ft2, tsi, custom
Barometric AccuracyN/AN/A55 Pa[4]
ConnectionBarb fittingHose, 5 ft (1.5 m), with built-in filter to 1/4BSPF, 1/4NPTF, and M20F adaptersHose, 5 ft (1.5 m), with built-in filter to 1/4BSPF, 1/4NPTF, and M20F adapters
Pressure Output Rate<30 Seconds (30 inH2O / 100 ml)<10 Seconds (35 psi / 5 ml)<90 Seconds (300 psi / 5 ml)
[1] FS specification applies to the span of the module range.
[2] Stability based on FS of the internal pressure module. Stability is 0.005%FS or 0.05 pa whichever is greater. Internal module is switchable.
[3] Specification based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode.
[4] 55 Pa uncertainty (k=2) includes calibration uncertainty, linearity, and long-term stability (<30 Pa per year). Barometer range of 60 to 110 kPa.

 

Selection Guide - Differential Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
inH2Ombar
DP025±0.25±0.62G0.2[2]100x  
DP050±0.5±1.25G0.1[3]100x  
DP1±1±2.5G0.05[4]100x  
DP2±2±5G0.05[4]100x  
DP5±5±10G0.05[4]50x  
DP10±10±25G0.05[4]20x 
DP20±20±50G0.0520x 
DP30±30±75G0.0520x 
DP50±50±125G0.053x  
DP100±100±250G0.023x  
DP150±150±350G0.023x  
DP300±300±700G0.023x  
DP400-380 to 400-950 to 1KG0.023x  
DP800-380 to 800-950 to 2KG0.023x  
DP1K-380 to 1K-950 to 2.5KG0.023x  
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.

 

Selection Guide - Gauge Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
psibar
CP10±10±0.7G0.02[5]3x 
CP15-13.5 to 15-0.95 to 1G0.02[5]3x 
CP30-13.5 to 30-0.95 to 2G0.02[5]3x 
CP35-13.5 to 35-0.95 to 2.5G0.02[5]3x 
CP50-13.5 to 50-0.95 to 3.5G0.02[5]3x  
CP100-13.5 to 100-0.95 to 7G0.02[5]3x  
CP150-13.5 to 150-0.95 to 10G0.02[5]3x  
CP200-13.5 to 200-0.95 to 14G0.02[5]3x  
CP300-13.5 to 300-0.95 to 20G0.02[5]3x  
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.

 

Electrical Specification
 RangeResolutionAccuracyNote
mA Measure±30 mA0.0001 mA0.01%RD+0.005%FSImpedance<10Ω
V Measure±30 V0.0001 V0.01%RD+0.005%FSImpedance >1MΩ
mA Source24 mA0.001 mA0.01%RD+0.005%FS20 mA @ 1K
Loop Power Source24 VN/A±1 V50 mA (Max Loading)
Pressure SwitchOpen, close. Support for mechanical switches and NPN/PNP digital switches.
Temperature Compensation41°F to 95°F (5°C to 35°C)
Temperature Coefficient< ± ( 0.001%RD + 0.001%FS ) / °C outside of 5°C to 35°C

 

General Specifications
SpecificationDescription
ChannelsFour total: one electrical, one internal pressure, two external pressure (measure only)
Enclosure IP RatingIP52 water and dust proof
BatteryRechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours
DisplayColor 800 x 480 TFT 5-inch touch screen
CommunicationsUSB, WiFi
Weight<4 lbs (<1.8 kg)
Size9.3 x 4.3 x 2.8 in (235 x 110 x 70 mm)
CertificationISO17025 accredited certificate with data included
HART CommunicationsOptional (ADT760-X-DL model)
Data LoggingOptional (ADT760-X-DL model), up to 1,000,000 readings (date and time stamped)
Task DocumentationOptional (ADT760-X-DL model) up to 1000 tasks
Automation FunctionsSwitch test, auto step, leak test
Misuse ProtectionUp to 30 V on any two sockets
Multi Lingual InterfaceEnglish, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
Pump Life>500,000 cycles
PowerRechargeable Li-Ion battery, external power: 110/220 V power adapter 10 V
Environment SpecificationsOperation: 32°F to 122°F (0°C to 50°C), 0-90% RH, less than 3,000 meters Compensated temperature: 32°F to 122°F (0°C to 50°C) Storage temperature: -4°F to 158°F (-20°C to 70°C)
Vibration and ShockVibration: 4g (20 to 2,000 Hz) Shock: 8g, 1 meter drop test
ComplianceCE
SoftwareACal, PCal, Land, LogII
Warranty1 year

 

Write Your Own Review