Additel ADT760-LLP-05 Automatic Handheld Pressure Calibrator (0.05%FS Accuracy)

SKU
ADT760-LLP-05
Manufacturer:
Additel

Key Features:

  • Max Pressure Range ±30 inH2O
  • Fully automatic calibrator with built-in pump and controller
  • Switchable internal pressure modules for expandable ranges
  • Accuracy (1 year) of 0.05%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • Optional HART communications
  • Optional data logging and task documenting
  • USB and Wi-Fi communication
Product Options:
$11,551.00

Secured and trusted checkout with

The Additel ADT760-LLP-05 is a handheld pressure calibrator that has a 0.05% full span accuracy and is designed for low pressure calibrators. The ADT760-LLP-05 max pressure range is ±30 inH2O (±75 mbar).

Pressure Specification
  760-LLP 760-D 760-MA
Max Pressure Range ±30 inH2O
(75 mbar)
-12.5 to 35 psi
(-0.86 to 2.5 bar)
-12.5 to 300 psig
(-0.86 to 20 bar.g)
Accuracy 0.05%FS[1] 0.02%FS[1] 0.02%FS[1][3]
Stability 0.005%FS[2] 0.005%FS[2] 0.005%FS[2]
Pressure Type Differential, Gauge Differential, Gauge Gauge, Absolute
Over Range Indication 120%
Resolution 6 digits
Measurement Units Pa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, mH2O@68°F, inH2O@20°C, kgf/cm2, mtorr, torr, lb/ft2, tsi, custom
Barometric Accuracy N/A N/A 55 Pa[4]
Connection Barb fitting Hose, 5 ft (1.5 m), with built-in filter to 1/4BSPF, 1/4NPTF, and M20F adapters Hose, 5 ft (1.5 m), with built-in filter to 1/4BSPF, 1/4NPTF, and M20F adapters
Pressure Output Rate <30 Seconds (30 inH2O / 100 ml) <10 Seconds (35 psi / 5 ml) <90 Seconds (300 psi / 5 ml)
[1] FS specification applies to the span of the module range.
[2] Stability based on FS of the internal pressure module. Stability is 0.005%FS or 0.05 pa whichever is greater. Internal module is switchable.
[3] Specification based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode.
[4] 55 Pa uncertainty (k=2) includes calibration uncertainty, linearity, and long-term stability (<30 Pa per year). Barometer range of 60 to 110 kPa.

 

Selection Guide - Differential Pressure
Module Module Range[6] Media Accuracy (%FS)[1] Burst Pressure 760-LLP 760-D 760-MA
inH2O mbar
DP025 ±0.25 ±0.62 G 0.2[2] 100x    
DP050 ±0.5 ±1.25 G 0.1[3] 100x    
DP1 ±1 ±2.5 G 0.05[4] 100x    
DP2 ±2 ±5 G 0.05[4] 100x    
DP5 ±5 ±10 G 0.05[4] 50x    
DP10 ±10 ±25 G 0.05[4] 20x  
DP20 ±20 ±50 G 0.05 20x  
DP30 ±30 ±75 G 0.05 20x  
DP50 ±50 ±125 G 0.05 3x    
DP100 ±100 ±250 G 0.02 3x    
DP150 ±150 ±350 G 0.02 3x    
DP300 ±300 ±700 G 0.02 3x    
DP400 -380 to 400 -950 to 1K G 0.02 3x    
DP800 -380 to 800 -950 to 2K G 0.02 3x    
DP1K -380 to 1K -950 to 2.5K G 0.02 3x    
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.

 

Selection Guide - Gauge Pressure
Module Module Range[6] Media Accuracy (%FS)[1] Burst Pressure 760-LLP 760-D 760-MA
psi bar
CP10 ±10 ±0.7 G 0.02[5] 3x  
CP15 -13.5 to 15 -0.95 to 1 G 0.02[5] 3x  
CP30 -13.5 to 30 -0.95 to 2 G 0.02[5] 3x  
CP35 -13.5 to 35 -0.95 to 2.5 G 0.02[5] 3x  
CP50 -13.5 to 50 -0.95 to 3.5 G 0.02[5] 3x    
CP100 -13.5 to 100 -0.95 to 7 G 0.02[5] 3x    
CP150 -13.5 to 150 -0.95 to 10 G 0.02[5] 3x    
CP200 -13.5 to 200 -0.95 to 14 G 0.02[5] 3x    
CP300 -13.5 to 300 -0.95 to 20 G 0.02[5] 3x    
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.

 

Electrical Specification
  Range Resolution Accuracy Note
mA Measure ±30 mA 0.0001 mA 0.01%RD+0.005%FS Impedance<10Ω
V Measure ±30 V 0.0001 V 0.01%RD+0.005%FS Impedance >1MΩ
mA Source 24 mA 0.001 mA 0.01%RD+0.005%FS 20 mA @ 1K
Loop Power Source 24 V N/A ±1 V 50 mA (Max Loading)
Pressure Switch Open, close. Support for mechanical switches and NPN/PNP digital switches.
Temperature Compensation 41°F to 95°F (5°C to 35°C)
Temperature Coefficient < ± ( 0.001%RD + 0.001%FS ) / °C outside of 5°C to 35°C

 

General Specifications
Specification Description
Channels Four total: one electrical, one internal pressure, two external pressure (measure only)
Enclosure IP Rating IP52 water and dust proof
Battery Rechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours
Display Color 800 x 480 TFT 5-inch touch screen
Communications USB, WiFi
Weight <4 lbs (<1.8 kg)
Size 9.3 x 4.3 x 2.8 in (235 x 110 x 70 mm)
Certification ISO17025 accredited certificate with data included
HART Communications Optional (ADT760-X-DL model)
Data Logging Optional (ADT760-X-DL model), up to 1,000,000 readings (date and time stamped)
Task Documentation Optional (ADT760-X-DL model) up to 1000 tasks
Automation Functions Switch test, auto step, leak test
Misuse Protection Up to 30 V on any two sockets
Multi Lingual Interface English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
Pump Life >500,000 cycles
Power Rechargeable Li-Ion battery, external power: 110/220 V power adapter 10 V
Environment Specifications Operation: 32°F to 122°F (0°C to 50°C), 0-90% RH, less than 3,000 meters Compensated temperature: 32°F to 122°F (0°C to 50°C) Storage temperature: -4°F to 158°F (-20°C to 70°C)
Vibration and Shock Vibration: 4g (20 to 2,000 Hz) Shock: 8g, 1 meter drop test
Compliance CE
Software ACal, PCal, Land, LogII
Warranty 1 year

 