We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Additel ADT273EX is an Intrinsically safe gauge pressure calibrator that has an optional HART communications capability. The Gauge version has a range of -15 to 60,000 PSIG. The ADT273EX has passed the most stringent ATEX, IECEX, CSA, and UKCA intrinsic safety certifications from authoritative organizations. Also its explosion-proof level is Ex ia IIC T4 Ga.
Functional Features |
|
Scaling |
User can convert measured current, voltage and frequency values into pressure, temperature and flow values. Three conversion functions available: linearity, square and square root |
Filtering |
Average sliding filter (sampling number: 1 ~ 50) First-order linear filter (First-order coefficient: 0.01 ~ 1) |
Switch |
The measurement value will be automatically displayed at the moment the switch change of state. The latest 8 state changes will be stored in the memory. |
Pressure Tare |
Tare value is set through the user interface |
Pressure stability indicator |
Stability time and criteria is selectable |
General Specifications |
|
Input Channels |
Top: 1 electrical signal measurement channel, φ4mm banana jacks |
Right side: 2 channels for external digital pressure modules, 5-core dedicated aviation plug |
|
Bottom: embedded digital pressure module (model ADT158Ex), field switchable. |
|
Internal: 1 embedded atmospheric pressure sensor |
|
Barometric Accuracy |
±55 Pa |
Measurement Rate |
mV, V, mA & frequency: 3 times/sec |
Pressure module: 1~10 times/sec selectable (3 as default) |
|
Barometer: 1 time/sec |
|
Power |
4000mAh, 14.4Wh explosion-proof intelligent lithium battery, charging time = 6~8 hours, battery can be charged independently Typical working time 100 hours (measurement mode) |
Environmental |
Guaranteed temperature range of technical specifications: (-10 ~ 50)°C |
Operating temperature: (-20 ~ 50)°C |
|
Storage temperature: (-30 ~ 70)°C |
|
Humidity: 0% to 95% RH, non-condensing. |
|
Altitude: 3000 meters |
|
Warm-up Time |
10 min to fully meet technical specifications |
Port Protection Voltage |
30V max |
Explosion-proof Grade |
ATEX & IECEX: Ex ia IIC T4 Ga (Ta = -10°C ~ 50°C) |
CSA: Class I, Division 1, Group A,B,C and D, T4 Ex ia IIC T4 Ga Class I, Zone 0, AEx ia IIC T4 Ga |
|
UKCA-EX |
|
CE Certification |
TUV IEC61326, IEC61010 |
Rohs Compliance |
Rohs II Directive 2011/65/EU, EN50581:2012 |
Protection Level |
IP67, 1 meter drop test |
Communication |
Isolate USB-Type C (slave), Bluetooth |
Display |
4.4-inch color display capacitive screen, transflective, with LED backlight |
Size |
6.97" x 4.13" x 2.04" (177 mm x 105 mm x 52 mm) which doesn't include bottom ADT158Ex. |
Weight |
1.98 lb (0.9 kg) |
Electrical Specifications |
||||
Specification |
Range |
Accuracy |
Resolution |
Note |
Voltage Measurement |
±300mV |
0.015%RDG + 0.005%FS |
1uV |
Impedance: >100MΩ |
±30V |
0.015%RDG + 0.005%FS |
0.1mV |
Impedance: >1MΩ |
|
Current Measurement |
±30mA |
0.015%RDG + 0.005%FS |
0.1uA |
Impedance: < 40Ω |
Frequency Measurement |
0.01~50000Hz (auto range) |
0.005% RDG + 2 last digit |
6-digit auto-resolution |
Min threshold voltage: 2.5V |
Units: Hz, kHz, MHz, CPM, CPH, s, ms, us |
||||
Switch On-Off Measurement |
Inspection voltage: (3 ~ 30)V |
|||
Response speed: < 10ms, supports wet and dry switch |
||||
Pulse Count |
0 ~ 9999999, optional rising edge and falling edge |
|||
Min threshold voltage: 2.5V |
||||
Loop Power |
20V ± 10%, max output impedance: 320Ω, max load current: 25mA |
Pressure Technichal Specifications |
|
Pressure resolution |
4, 5, or 6 digit resolution (user selectable) |
Temperature Compensation |
-10°C~50 °C |
Pressure Module Type |
Built-in digital pressure module: ADT158Ex, for more detailed information, please see ADT 158Ex datasheet. External digital pressure module: ADT161Ex,for more detailed information, please see ADT 161Ex datasheet. |
Specifications |
Refer to the technical specification of the ADT158Ex and ADT161Ex |
High Static Pressure and Differential Pressure Synthesis Index |
Two modules must be with the same range; Typical Differential pressure accuracy of 0.002%FS or 0.02%RD, whichever is greater when using two 0.02%FS external modules. Typical Differential pressure accuracy of 0.002%FS or 0.05%RD, whichever is greater when using two 0.05%FS external modules. |
Gauge Pressure [1] |
|||||
P/N |
Pressure Range |
Media [2] |
Accuracy (%FS) |
Burst Pressure |
|
(psi) |
(bar) |
||||
V15 |
-15 |
-1 |
G |
0.02 |
3× |
GP2 |
2 |
0.16 |
G |
0.05 |
3× |
GP5 |
5 |
0.35 |
G |
0.05 |
3× |
GP10 |
10 |
0.7 |
G |
0.02 |
3× |
GP15 |
15 |
1 |
G |
0.02 |
3× |
GP30 |
30 |
2 |
G |
0.02 |
3× |
GP50 |
50 |
3.5 |
G , L |
0.02 |
3× |
GP100 |
100 |
7 |
G , L |
0.02 |
3× |
GP150 |
150 |
10 |
G , L |
0.02 |
3× |
GP300 |
300 |
20 |
G , L |
0.02 |
3× |
GP500 |
500 |
35 |
G , L |
0.02 |
3× |
GP600 |
600 |
40 |
G , L |
0.02 |
3× |
GP1K |
1000 |
70 |
G , L |
0.02 |
3× |
GP1.5K |
1500 |
100 |
G , L |
0.02 |
3× |
GP2K |
2000 |
140 |
G , L |
0.02 |
3× |
GP3K |
3000 |
200 |
G , L |
0.02 |
3× |
GP5K |
5000 |
350 |
G , L |
0.02 |
3× |
GP10K |
10000 |
700 |
G , L |
0.02 |
2× |
GP15K |
15000 |
1000 |
G , L |
0.05 |
2x |
GP20K |
20000 |
1400 |
G , L |
0.05 |
1.5x |
GP25K |
25000 |
1600 |
G , L |
0.05 |
1.5x |
GP30K |
30000 |
2000 |
G , L |
0.05 |
1.5x |
GP36K |
36000 |
2500 |
G , L |
0.05 |
1.5x |
GP40K |
40000 |
2800 |
G , L |
0.05 |
1.35x |
GP50K |
50000 |
3500 |
G , L |
0.1 |
1.2x |
[1] Sealed gauge pressure for above 1000 psi |
|||||
[2] G=Gas, L=Liquid |