We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
AC Amps Measurement - Jaw Input (45Hz to 400Hz)
Range | Resolution | Accuracy | Overload Protection |
40A | 0.01A | ±2.9% +15 dgts | 600V |
400A | 0.1A | ±1.9% +8 dgts |
DC Low Amps Measurement (test lead input)
Range | Resolution | Accuracy | Overload Protection |
400µA | 0.01µA | ±1.2% +3 dgts | 2000µA / 600V |
2000µA | 0.1µA |
AC Low Amps Measurement (test lead input)
Range | Resolution | Accuracy | Overload Protection |
400µA | 0.01µA | ±2.0% +5 dgts | 2000µA / 600V |
2000µA | 0.1µA | ±1.5% +5 dgts |
DC Volts Measurement
Range | Resolution | Accuracy | Overload Protection |
400mV | 0.1mV | ±0.5% +4 dgts | 600V |
4V | 1mV | ||
40V | 10mV | ||
400V | 100mV | ||
1000V | 1V | ±0.8% +10 dgts |
AC Volts Measurement (45Hz to 400Hz)
Range | Resolution | Accuracy | Overload Protection |
4V | 1mV | ±2.0% +5 dgts | 600V |
40V | 10mV | ||
400V | 100mV | ||
750V | 1V |
Ohms Measurement
Range | Resolution | Accuracy | Overload Protection |
400Ω | 100mΩ | ±1.0% +4 dgts | 600V |
4kΩ | 1Ω | ||
40kΩ | 10Ω | ||
400kΩ | 100Ω | ||
4MΩ | 1kΩ | ||
40MΩ | 10kΩ | ±2.0% +4 dgts |
Diode Test
Range | Open Circuit Voltage | Test Current (typical) | Overload Protection |
2.0V | < 3.0V DC | 0.25mA | 600V |
Capacitance Measurement
Range | Resolution | Accuracy | Overload Protection |
40nF | 0.01nF | ±3.5% +6 dgts | 600V |
400nF | 0.1nF | ||
4µF | 0.001µF | ||
40µF | 0.01µF | ||
400µF | 0.1µF | ||
4000µF | 1µF |
Temperature Measurement
Range | Resolution | Accuracy | Overload Protection |
-22˚ to 14˚F (-30˚ to -10˚C) | 0.1˚F (0.1˚C) | ±5.4˚F (±3.0˚C) | 30V |
15˚ to 752˚F (-9˚ to 400˚C) | 0.1˚F (0.1˚C) | ±1.0% +3.6˚F (±1.0% +2.0˚C) |
Frequency Measurement
Range | Resolution | Accuracy | Overload Protection |
9.999Hz | 0.001Hz | ±0.1% +4 dgts | 600V |
99.99Hz | 0.01Hz | ||
999.9Hz | 0.1Hz | ||
9.999kHz | 1Hz | ||
99.99kHz | 10Hz |
Minimum frequency: 0.5Hz, DC V offset should be zero
Sensitivity: > 1.0V rms
Duty (%) Cycle Measurement
Range | Accuracy | Overload Protection |
01. to 99.9% | ±(0.2% per kHz +0.1%) +5 count | 600V |
0.5Hz to 100KHz (pulswidth > 2µ sec)
Continuity Measurement
Open Circuit voltage <2.7V | Overload Protection |
Threshold Approximately <20Ω | 600V |
DL379KIT Includes
- - Digital Clamp Meter (DL379)
- - Extended Clamp Head (CH3)
- - Test Leads (ATL59)
- - Zippered Case
- - Batteries 2(AA)
- - K Type Temperature Probe (ATT29)