The model HX92A is an economical humidity transmitter, providing on-site continuous monitoring of relative humidity. It is available with either voltage or 2-wire current output. The transmitter output is linearized, and RH readings are temperature compensated. A thin-film polymer capacitor senses relative humidity. The sensor is protected by a stainless mesh-type filter that is easily removable for cleaning. The case and weathertight protection, and screws are provided for mounting the unit via internal hole. An unusually low minimum voltage of 6V allows the use of large impedances for longer wire runs.
Specifications:
Input Voltage Range 24 Vdc nominal (6 to 30 Vdc)
Measuring Range RH: 3 to 95% Temperature: -20 to 75 Deg C (-4 to 167 Deg F)
Accuracy RH: +/-2.5% RH from 20 to 80% RH; +/-3.1% RH below 20 and above 80% RH @ 25 Deg C with temp coefficient of +/-0.1%RH/Deg F
Output HX92AC: 4 to 20 mA for 0 to 100% RH HX92AV: 0 to 1Vdc for 0 to 100% RHRH
Temperature Compensation: -20 to 75 Deg C (-4 to 167 Deg F) RH Time: Constant (90% response at 25 Deg C, in moving air at 1m/s):>10 seconds, 10 to 90% RH; >15 seconds, 90 to 10% RH Repeatability: +/-1% RH, 0.5 Deg F Housing: ABS plastic watertight enclosure; meets NEMA 1, 2, 3, 3R, 4, 4X, 5, 12 and 13 specifications Connections: Liquid-tight nylon with neoprene gland, for 0.09 to 0.265" diameter cable; internal 4-pin terminal block accepts 14 to 22 gage wire
Dimensions
Enclosure: HX92A(*) & HX92A(*)-D: 49.8 x 64.8 x 34.8 mm (1.96" x 2.55 x 1.37") Probe: HX92A(*)-D: 15.7 D x 124.5 mm L (0.620" x 4.9") Weight: HX92A(*) 82 g (2.9 oz); HX92A(*)-D 100 g (3.5 oz)
|
The Martel MECPS is a compact power supply may be used to power various DC operated peripherals and input/output modules on PLC's or transmitters in process control. It is small, economical, and easy to mount with built in mounting slots. Available with 5
|
Newport Infinity IDP 4 Digit Process Meter accepts DC Process Signals and can be scaled to from -1999 to 9999. The IDP accepts both DC voltage and mA process loop signals
|
|


|
|