Hanna HI 98804 K, J, T-Type Thermocouple Printing and Logging Thermometers
|
|
Item Number: HI 98804
Manufacturer: Hanna
Part Number: HI 98804
|
Hanna HI 98804 K, J, T-Type Thermocouple Printing and Logging Thermometers
HI 98804 thermometer combines the high accuracy and fast response time of the printing series with an extensive logging feature and infrared computer transfer system.
These meters support K, J or T-thermocouple probes, up to 4 for HI 98804.
All data are coupled with date, time, sample and probe number. Measurements can be stored automatically at defined intervals (user-selectable from 1 to 180 minutes), or the current reading can be printed or logged-on-demand by just pressing a button.
The backlit LCD allows operations even in poorly lit areas.
Computer connection is made through the HI 9200 infrared interface and serial port via HI 92000 application software to transfer all logged data.
Both models can be powered with batteries or 12 Vdc input.
HANNA® produces a wide range of K-type thermocouple probes that can be used with this thermometer for many applications (HI 766 series).
Specifications
| Range
|
Type K
|
-200.0 to 999.9°C; 1000 to 1370°C;
-300.0 to 999.9°F; 1000 to 2500°F
|
| Range
|
Type J
|
-200.0 to 760.0°C; -300.0 to 999.9°F; 1000 to 1400°F
|
| Range
|
Type T
|
-200.0 to 400.0°C; -300.0 to 750.0°F
|
| Resolution
|
Type K
|
0.1°C (-99.9 to 999.9°C); 0.2°C (-200.0 to -100.0°C); 1°C (1000 to 1370°C);
0.2°F (-199.9 to 999.9°F);
0.3°F (-300.0 to -200.0°F); 1°F (1000 to 2500°F)
|
| Resolution
|
Type J
|
0.1°C (-200.0 to 999.9°C);
0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)
|
| Resolution
|
Type T
|
0.1°C (-99.9 to 999.9°C); 0.2°C (-200.0 to -100.0°C);
0.1°F (300.0 to 750.0°F); 0.2°F (-149.9 to 300.0°F); 0.3°F (-300.0 to -150.0°F)
|
| Accuracy
|
|
±0.5°C (-200.0 to 999.9°C); ±1°C (outside);
±1°F (for 1 year, excluding probe error)
|
| Channels
|
|
4
|
| Probe
|
|
K, J, T-type thermocouple (not included)
|
| Cold Junction
|
|
NTC 10 K; 0.1°C resolution; ±0.3°C accuracy
|
| Printer
|
|
Low power inpact, 14 characters per line,
using 38 mm plain paper (HI 710034)
|
| Printing Interval
|
|
Selectable at 1, 2, 5, 10, 15, 30, 60, 120 or 180 minutes
|
| Logging Interval
|
|
Selectable at 1, 2, 5, 10, 15, 30, 60, 120 or 180 minutes
|
| PC Connection
|
|
HI 9200 interface through RS232 serial port
using HI 92000 software (not included)
|
| Power Supply
|
|
4 x 1.5V AA / approx. 350 hours continuous use (without printing and backlight);
auto-off after 5, 10, 15, 30, 45 or 60 minutes of non-use (user-selectable);
or 12 Vdc input
|
| Environment
|
|
0 to 50°C (32 to 122°F); RH max 95%
|
| Dimensions
|
|
220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
|
| Weight
|
|
550 g (1.2 lb.)
|
|
|


|
|