Hanna HI 9126 Calibration Check Portable pH/ORP Meter
|
Item Number: Hanna HI 9126
|
|
Hanna Calibration Check Portable pH/ORP Meter - HI 9126
The HI 9126 pH/ORP meter includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.
Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range.
The HI 9126 can store and recall readings at the touch of a button.
HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.
Specifications:
| Range
|
pH
|
-2.00 to 16.00 pH
|
|
|
ORP
|
±699.9 mV; ±1999 mV
|
|
|
Temperature
|
-20.0 to 120.0°C / -4.0°F to 248.0°F
|
| Resolution
|
pH
|
0.01 pH
|
|
|
ORP
|
0.1 mV; 1 mV
|
|
|
Temperature
|
0.1°C / 0.1 °F
|
| Accuracy @ 20°C
|
pH
|
±0.01 pH
|
|
|
ORP
|
±0.2 mV; ±1 mV
|
|
|
Temperature
|
±0.4°C/±0.8°F (excluding probe error)
|
pH Calibration
Check
|
|
yes, check of the electrode status during calibration
|
| Calibration
|
pH
|
automatic, one or two point with seven memorized buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
|
|
|
Offset
|
±1 pH
|
|
|
Slope
|
from 80 to 108%
|
Temperature
Compensation
|
|
automatic or manual, -20 to 120°C (-4 to 248°F) without temperature probe
|
| pH Electrode
|
|
HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
|
| Temperature Probe
|
|
HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
|
| Input Impedance
|
|
1012 Ohms
|
| Battery Type / Life
|
|
1.5V (3) AAA / approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)
|
| Environment
|
|
0 to 50°C (32 to 122°F); RH max 100%
|
| Dimensions
|
|
185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
|
| Weight
|
|
300 g (10.6 oz.)
|
|
The Hanna HI 98103 Checker 1 is an ideal pocket pH Tester with +/-0.2 pH accuracy, 0.01 pH resolution and a replaceable electrode
|
The Hanna HI 98120 is the most advanced solution in ORP measurements. It is an ideal pocket ORP Tester with +/-2 mV accuracy and a replaceable electrode.
|
The Hanna HI 98121 is a combination pH and ORP waterproof tester with advanced functions. It is designed for simultaneous pH (+/-0.05 pH accuracy) and ORP (+/-2 mV accuracy) measurements.
|
The Hanna HI 98130 is a combination waterproof tester that offers high accuracy pH, EC/TDS and temperature measurements in a single tester! No more switching between meters for your routine measurements.
|
The Hanna HI 98129 waterproof tester offers a combination of high accuracy pH, EC/TDS and temperature measurements in a single tester! No more switching between meters for your routine measurements.
|
Our Price: This unit is discontinued. Please call (732) 632-6400 for replacement options.
The Hanna HI 9024 is a microprocessor- based pH meters in waterproof casings. It measures pH and temperature and includes probes and a hard case.
|
The HI 9210N heavy-duty pH meter is designed to provide laboratory results and accuracy under the harshest of industrial conditions. HI 9210N is supplied with a rugged pH electrode which, in addition to the pH reference system and sensitive bulb, incorpor
|
Our Price: This unit is discontinued. Please call (732) 632-6400 for replacement options.
The Hanna HI 9025 is a microprocessor- based pH/ORP meters in waterproof casings. It measures pH, ORP in mV and temperature and includes probes and a hard case.
|
|


|
|