Fluke i400s AC Current Clamp
|
Item Number: i400s
Manufacturer: Fluke
Part Number: i400s
Product Options
* denotes required field
NIST Calibration - Current Clamp*
|
|
Fluke i400s AC Current Clamp
Features:
- Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
- Specially designed to offer maximum utility in a compact shape
- Take accurate current readings without breaking the circuit
- Soft non-slippery overmold handle
- Optional PM9081/001 BNC/Banana adapter for DMM's
- Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output
- Max. conductor 32 mm
| Specifications |
| Nominal current range: |
| 40 A Range |
0.5 A to 40 A |
| 400 A Range |
5 A to 400 A | |
| Basic accuracy: |
| 40 A Range |
2% + 0.015 A (45-400 Hz) |
| 400 A Range |
2% + 0.04 A (45-400 Hz) | |
| Phase Shift: |
| 40 A Range |
|
| 0.5 to 1 A |
Unspecified |
| 1 A to 5 A |
4 Deg |
| 5 A to 10 A |
3 Deg |
| 10 A to 20 A |
3 Deg |
| 20 A to 40 A |
2 Deg |
| 40 A to 400 A |
NA |
| 400 A Range |
|
| 0.5 to 1 A |
NA |
| 1 A to 5 A |
NA |
| 5 A to 10 A |
Unspecified |
| 10 A to 20 A |
2 Deg |
| 20 A to 40 A |
2 Deg |
| 40 A to 400 A |
1.5 Deg | |
| Typical Bandwidth: |
| 40 A Range |
5 Hz - 10 kHz |
| 400 A Range |
5 Hz - 10 kHz | |
| Output level(s): |
| 40 A Range |
10 mV/A |
| 400 A Range |
1 mV/A | |
| Crest Factor: |
| 40 A Range |
3 |
| 400 A Range |
3 to 300 A |
|
2.5 to 400 A | |
| Safety Specifications |
| Safety |
|
CAT IV 600 V, CAT III, 1000 V | |
| Maximum Non-Destructive Current |
|
| Mechanical & General Specifications |
| Warranty |
|
| Maximum conductor size |
|
| Output cable length |
|
| BNC Adapter |
|
| Dimensions |
|
| Weight |
|
|
|


|
|