Fluke 714 Thermocouple Calibrator
|
Item Number: Fluke-714
Manufacturer: Fluke
Part Number: Fluke-714
Product Options
* denotes required field
NIST Traceable Calibration - Fluke 714*
|
|
Fluke 714 Thermocouple Signal Simulator and Calibrator
The Fluke 714 is a simple yet powerful thermocouple calibration instrument. Connect to the device under test using standard thermocouple wire and the Fluke 714's built-in mini thermocouple jack. Source or measure 9 standard thermocouple types, including Type J, K, T, E, R, S, B, N, L, U. If you need a low value DC source, the Fluke 714 sources and measures DC mV signals also. The Fluke 714 calibrator is EMI-tolerant, dust and splash-resistant, and features a removeable battery door for quick and easy battery changes without disturbing calibration seals.
Fluke 714 - Features:
- Measure temperature signals from thermocouples
- Simulate and output thermocouple signals
- Generate 9 Thermocouple Types ( Type J, K, T, E, R, S, B, N, L, U)
- Calibrate Linear mV Signals, Indicators, Controllers, Transmitters, Recorders and Alarm/Trip devices
- Select Degrees ºF/ºC Scales
- Uses standard mini thermocouple jack connection
Technical Specifications - Fluke 714 Thermocouple Calibrator:
| Maximum Voltage
|
30 Volts
|
| Non-Operating Temperature
|
-40 C to 60 ºC
|
| Operating Temperature
|
-10 C to 55 ºC
|
| Relative Humidity
|
95% (10 C to 30 ºC); 75% (30 ºC to 40 ºC);
45% (40 C to 50 ºC); 35% (50 ºC to 55 ºC)
|
| Operating Altitude
|
3,000 max
|
| Shock
|
1m drop test
|
| Vibration
|
Random, 2g, 5-500 Hz
|
| Safety
|
CSA C22.0 No. 1010.1:1992
|
| EMC
|
EN50082-1:1992 and EN55022:1994 Class B
|
| Size/Weight
|
187 mm L x 27mm W x 32 mm D
(7.35 in L x 3.41 in W x 1.25 in D)
330g (12 oz)
|
| Size/Weight (with Holster)
|
201mm L x 98 mm W x 52 mm D
(7.93 in L x 3.86 in W x 2.06 in D)
600g (21oz)
|
| Power
|
9V Battery ANSI/NEDA 1604A or
IEC 6LR619V alkaline
|
| Battery Life
|
4 to 20 hours, typical, depending on
functions used
|
| Warranty
|
3 years
|
| Function
|
Range
|
Resolution
|
Accuracy
|
Measure/Simulate
Thermocouple
|
-200 to 1800 ºC
depending on type
(Type K,-200 to 1370 ºC)
|
0.1 ºC or ºF
(1 C or F; Type B R S)
|
0.3 ºC + 10uV
(Type K,-200 to 1370 ºC)
|
| Measure/Simulate mV
|
-10 to 75 mV
|
0.01mV
|
0.025% + 1 count
|
Notes: 9 TC Types: J K T E R S B per NIST 175 and ITS-90; Type L U per DIN 43710 and IPTS-68
|
Our Price: Select Size for Price
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
Fluke C125 Zippered Meter Case with detachable external pouch
|
Thermocouple Wire Test Lead Cable Kit, includes Type J, K, T, E thermocouple cable with male mini connector on one end.
|
Thermocouple Wire Test Lead Cable Kit, Includes Type R/S, N, B cable with male mini connector on one end.
|
|


|
|