Fluke 753 Documenting Process Calibrator

Fluke 750 Series Documenting Process Calibrator

Our Price: $4,995.00
Item Number: Fluke-753
Manufacturer: Fluke
Part Number: Fluke-753

Product Options

Fluke 750 Series Calibration Options

Fluke 753 Documenting Process Calibrator


     Fans of the time tested Fluke 743B have a reason to rejoice!  Fluke presents the new and better Fluke 753 as a direct replacement for the ever popular Fluke 743.  There is no need to retrain technicians, the new user interface is nearly identical to the popular 740 series calibrators and an improved display makes these new calibrators a winner for those used to using 740 series calibrators.

     Improvements include a new brighter, bigger and easier to read display, HART (Fluke 754 only) connectability through the mA terminals, improved test lead set, Li-ion battery, improved RTD accuracy and more. Added bonus, the new 750 series DPCs include the innovative new C799 Field Softcase.


      The Fluke 753 Documenting Process Calibrator automates calibration procedures and captures your data. Use the PC interface for downloading procedures, lists, and instructions to the 753 and for uploading data for printing, archiving and analysis.


Features of the Fluke 753 and 754 Process Calibrators:

    • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments

    Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters

    Power transmitters during test using loop supply with simultaneous mA measurement

    Measure/source pressure using any of 29 Fluke pressure modules

    Measure and source simultaneously with one compact, rugged, reliable tool

    Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results

    Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing,
      square root DP flow testing, programmable measurement delay and more

    Control the temperature of selected Hart Scientific Dry Blocks

    Handle fast pulsed RTD transmitters and PLCs in RTD source mode with 1 ms response time

    English, French, German, Italian, and Spanish languages

    Three-year warranty

Fluke 754 Documenting Process Calibrator is more advanced than the Fluke 753 by adding:

     The 754 includes integrated HART communication capability. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.


Additional 754 features:

    Monitor, control and calibrate HART instrumentation

    Interrogate HART devices to determine type, manufacturer,model and tag-ID

    Read HART PV, smart transmitter digital output

    Make field adjustments to ranging, damping and more

    Change/assign the HART transmitter tag

    Re-configure HART temperature sensor (e.g., TC to RTD)

    Perform HART sensor trim and output trim

    Perform HART loop test

FLUKE-753 Documenting Process Calibrator, FLUKE-754 Documenting Process Calibrator-HART include:


 Specifications - Fluke 753 & Fluke 754 Process Calibrators

Measurement Accuracy
Voltage DC

 1 Year  2 Years
100.000 mV        0.02%+0.005% mV  0.03%+0.005 mV
3.00000 V  0.02%+0.00005% V  0.03%+0.00005 V
30.000 V  0.02%+0.0005% V  0.03%+0.0005 V
300.00 V  0.05%+0.05% V  0.07%+0.05 V
Voltage AC
Range
40 to 500 Hz     
 Resolution  1 Year 2 Years 
3.000 V  0.001 V  0.5%+0.002 V  1.0%+0.004 V
30.00 V  0.01 V  0.5%+0.02 V  1.0%+0.04 V
300.0 V  0.1 V  0.5%+0.2 V  1.0%+0.2 V
Current DC
   1 Year  2 Years
30.000 mA          0.01% + 5 uA   0.015%+7 uA
110.00 mA  0.01% + 20 uA  0.015%+30 uA
Resistance
   1 Year  2 Years
10.000 O          
 0.05% + 50 mO  0.07%+70 mO
100.00 O  0.05% + 50 mO  0.07%+70 mO
1.0000 kO   0.05% + 500 mO  0.07%+0.5 O
10.000 kO  0.1% + 10 O  0.15%+15 O
Frequency
   Resolution  Accuracy (2 Years)
1.00 to 110.00 Hz  0.01 Hz  0.05 Hz
110.1 to 1100.0 Hz  0.1 Hz  0.5 Hz
1.101 to 11.000 kHz   0.001 kHz  0.005 kHz
11.01 to 50.00 kHz  0.01 kHz  0.05 kHz

 

Source Accuracy
Voltage DC
   1 Year  2 Years
100.000 mV         
 0.01%+0.005% mV  0.015%+0.005% mV
1.00000 V  0.01%+0.00005% V  0.015%+0.0005% V
15.0000 V  0.01%+0.0005% V  0.015%+0.0005% V
Current DC
   1 Year 2 Years 
22.000 mA (Source)  0.01%+ 0.003 mA  0.02%+ 0.003 mA
Current Sink (Simulate)  0.02% + 0.007 mA  0.04% + 0.007 mA
Resistance
   1 Year  2 Years
10.000 O             
 0.01% + 10 mO  0.015% + 15 mO
100.00 O  0.01% + 20 mO  0.015% + 30 mO
1.0000 kO  0.02% + 0.2 O  0.03% + 0.3 O
10.000 kO  0.02% + 3 O  0.03% + 5 O
Frequency
   2 Years
0.1 to 10.99 Hz  0.01 Hz
0.01 to 10.99 Hz  0.01 Hz
11.00 to 109.99 Hz  0.1 Hz
110.0 to 1099.9 Hz  0.1 Hz
1.100 to 21.999 kHz  0.002 kHz
22.000 to 50.000 kHz        
 0.005 kHz

Technical Data
Data Log Functions
Measure functions:  Voltage, current, resistance, frequency, temperature, pressure
Reading rate:  1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:  8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Rate:  4 steps/second
Trip detect:  Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:  Selectable, 26 V
Accuracy:  10%, 18 V minimum at 22 mA
Maximum current:  25 mA, short circuit protected
Maximum input voltage:  50 V DC
Step Functions
Source Functions  Voltage, current, resistance, frequency, temperature
Manual Step  Selectable step, change with arrow buttons
Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat

 

Environmental Specifications
Operating Temperature

 -10 °C to +50 °C
Storage Temperature

 -20 °C to +60 °C
Dust/water resistance

 Meets IP52, IEC 529
Operating Altitude

 3000 m above mean sea level (9842 ft)

 

Safety Specifications
Agency Approvals

 CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

 

Mechanical & General Specifications
Size

 136 x 245 x 63 mm (5.4“ x 9.6 x 2.5)
Weight

 1.2 kg (2.7 lb)
Batteries
Internal Battery Pack Li-ion:  7.2V, 4400mAh, 30 Wh
Battery Life

 >8 hours typical
Battery Replacement

 Via snap-shut door without opening calibrator; no tools required
Side port connections

 Pressure module connector

 USB Connector to interface to your PC
   Digital instrument (HART) connector

 Connection for optional battery charger/eliminator
Data storage capacity

 1 week of calibration procedures results
90 day specifications

 The standard specification interval for the 750 Series are 1 and 2 years.

 Typical 90 day measurement and source accuracy can be estimated by

 dividing the one year "% of reading" or "%of output" specifications by 2.

 Floor specifications, expressed as "% of full scale" or

 "counts" or "ohms" remain constant.

 

Temperature, Resistance Temperature DetectorsHBZSEL28
Degrees or % of reading
Type (a) Range °C Measure °C 2 Source current Source °C Allowable current 3
  1 year 2 year   1 year 2 year  
100 O Pt (385) -200 to 100
100 to 800
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
200 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
500 µA 0.06 °C
0.017 % + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
500 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
250 µA 0.06 °C
0.017% + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
1000 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04% + 0.10 °C
150 µA 0.06 C
0.017 % + 0.05 °C
0.12 C
0.034 % + 0.10 °C
0.1 mA to 1 mA
100 O Pt (3916) -200 to 100
100 to 630
0.07 °C
0.02 % +0.05 °C
0.14 °C
0.04 % +0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
100 O Pt (3926) -200 to 100
100 to 630
0.08 °C
0.02 % +0.06 °C
0.16 °C
0.04 % +0.12 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
10 O Cu (427) -100 to 260 0.2 °C 0.4 °C 3 mA 0.2 °C 0.4 °C 0.1 mA to 10 mA
120 O Ni (672) -80 to 260 0.1 °C 0.2 °C 1 mA 0.04 °C 0.08 °C 0.1 mA to 10 mA

 

Temperature, Thermocouples
Type Source °C Measure °C Source °C


1 year 2 years 1 year 2 years

E

-250 to -200 1.3 2.0 0.6 0.9

-200 to -100 0.5 0.8 0.3 0.4

-100 to 600 0.3 0.4 0.3 0.4

600 to 1000 0.4 0.6 0.2 0.3

N

-200 to -100 1.0 1.5 0.6 0.9

-100 to 900 0.5 0.8 0.5 0.8

900 to 1300 0.6 0.9 0.3 0.4

J

-210 to -100 0.6 0.9 0.3 0.4

-100 to 800 0.3 0.4 0.2 0.3

800 to 1200 0.5 0.8 0.3 0.3

K

-200 to -100 0.7 1.0 0.4 0.6

-100 to 400 0.3 0.4 0.3 0.4

400 to 1200 0.5 0.8 0.3 0.4

1200 to 1372 0.7 1.0 0.3 0.4

T

-250 to -200 1.7 2.5 0.9 1.4

-200 to 0 0.6 0.9 0.4 0.6

0 to 400 0.3 0.4 0.3 0.4

B

600 to 800 1.3 2.0 1.0 1.5

800 to 1000 1.0 1.5 0.8 1.2

1000 to 1820 0.9 1.3 0.8 1.2

R

-20 to 0 2.3 2.8 1.2 1.8

0 to 100 1.5 2.2 1.1 1.7

100 to 1767 1.0 1.5 0.9 1.4

S

-20 to 0 2.3 2.8 1.2 1.8

0 to 200 1.5 2.1 1.1 1.7

200 to 1400 0.9 1.4 0.9 1.4

1400 to 1767 1.1 1.7 1.0 1.5

C

0 to 800 0.6 0.9 0.6 0.9

800 to 1200 0.8 1.2 0.7 1.0

1200 to 1800 1.1 1.6 0.9 1.4

1800 to 2316 2.0 3.0 1.3 2.0

L

-200 to -100 0.6 0.9 0.3 0.4

-100 to 800 0.3 0.4 0.2 0.3

800 to 900 0.5 0.8 0.2 0.3

U

-200 to 0 0.6 0.9 0.4 0.6
0 to 600 0.3 0.4 0.3 0.4

BP

0 to 1000 1.0 1.5 0.4 0.6

1000 to 2000 1.6 2.4 0.6 0.9

2000 to 2500 2.0 3.0 0.8 1.2

XK

-200 to 300 0.2 0.3 0.2 0.5
300 to 800 0.4 0.6 0.3 0.6