Druck TRX-II Documenting Process Calibrator
Our Price: Discontinued Item - Please CALL for replacement Options
Item Number: TRX-II
Manufacturer: Druck (GE)
Part Number: TRX-II
Product Options
* denotes required field
NIST Traceable Calibration*
|
|
Druck TRX-II DocumentingProcess Calibrator
The Druck TRX-II Calibrators is a self-contained, battery powered package that simulates and measures RTD's, thermocouples and resistance, as well as sourcing and reading milliamps, millivolts, volts and frequency. The rugged design includes an impact resistant enclosure which is fastened to the carrying case for convenience and safety. Dedicated alphanumeric and documenting keypads surround a large LCD panel with dual readout and backlight. The TRX-II is also available as an intrinsically safe version.
Features:
- Simulate & Read 9 RTD's & 12 Thermocouple Types
- Source & Measure mV, mA, Volts, Ohms, Hz, Pulses
- Measure Pressure with Optional Modules
- Reads Pressure from Vacuum to 10,000 PSIG
- Dual Display: Source & Measure
- Data Storage for Field Calibrations (1 or 2 MB)
- Data Transfer Via RS-232 or PCMIA Cards
- 0.01% of Reading Typical Accuracy
- 0.05% Accuracy for Pressure Readings
- Handles Gauge, Differential or Gauge Pressure
- 24 VDC Loop Power Source
- Large Backlight Display
- Operates in 6 Languages
- Weighs Only 2.6 Pounds
Technical Specifications:
|
Measure mA: |
0-52 mA, +/-0.02% Accuracy |
|
Measure mV: |
0-600 mV, +/-0.03% Accuracy |
|
Measure V: |
0-60 V, +/-0.03% Accuracy |
|
Measure Frequency: |
0-20,000 Hz, +/- 0.006% |
|
Measure Counts/Total: |
108 Counts, +/-2 Counts |
|
Measure Pressure: |
-14.7 to 10,000 PSI; +/-0.05% FS |
|
Output mA: |
0-24 mA, +/-0.02% Accuracy |
|
Output mV: |
-10-100 mV, +/-0.015% Accuracy |
|
Output V: |
0-12 V, +/-0.015% Accuracy |
|
Output Frequency: |
0-20,000 Hz, +/- 1 Hz |
|
Output Pulses: |
0-6000 +/-1 pulse/Min,
0-99,999 +/-1 Pulse/Hr |
|
Source/Measure RTD's: |
9 RTDS; Pt, Ni, Cu; +/-0.6 F Avg. |
|
Source/Measure T/C's: |
12 T/Cs; J, L, K, T, U, B, R, S, E, N, C, D, +/-0.6 F Avg. |
|
Units: |
Deg C or F, 15 Pressure Units |
|
Pressure Connection: |
1/4" NPT Female |
|
Steps: |
10 Programmable |
|
Ramp: |
Programmable Up/Down/Dwell |
|
Electrical Scaling: |
5 Digits Plus Sign on All Ranges |
|
Data Logging: |
1 MB to 8 MB |
|
PC Interface: |
RS-232 7 PCMIA Cards |
|
Languages: |
English, French, Spanish, Italian, German, Portuguese |
|
Display: |
2.6 x 1.6 Graphic LCD, Backlight |
|
Readout: |
Typically 5 Readings/Second |
|
Power Supply: |
4 x 1.5 V C Cells or 4 x 1.2V NiCads |
|
Size: |
2.65 Pounds, 8.25" x 4.75" x 2" |
Druck TRX-II Pressure Module Available Ranges:

Optional Remote pressure sensors offer a cost effective means of expanding the capabilities of the TRX II, for example:
- Calibration of pressure transmitters
- Testing pressure switches
- For differential pressure applications
- For flow measurement calibrations
The capability of the TRX II can be extended by adding up to 8 external pressure sensors (connected one at a time). With ranges from 1 to 10,000 psi and all welded stainless steel and Hastelloy construction, sensors can be chosen to suit many applications. Remote pressure sensors require a mating cable approximately 4.5 feet in length. One end connection interfaces with the remote pressure sensor electrical input and one end mates with the TRX II remote pressure sensor electrical input (please refer to Option B2). Druck has applied the latest technology and production techniques to develop these sensors which are digitally corrected for nonlinearity and temperature effects.Over 50 sensor ranges are available including gauge, absolute and differential versions and with accuracy better than 0.05% FS, even the most up to date pressure instrumentation can be maintained and calibrated.
|
Our Price: Select Size for Price
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
Thermocouple Wire Test Lead Cable Kit, includes Type J, K, T, E thermocouple cable with male mini connector on one end.
|
|


|
|