AEMC 501 Clamp On Meter
The Clamp-On Meter Model 501 is a general-purpose professional clamp-on. A strong mechanical case design, quality materials, full ranges and compliance to international safety and quality standards ensure a professional and reliable tool. The Model 501 is auto-ranging, and provides the user with AC Volts, DC Volts, AC Amperes, resistance, and continuity. The Model 501 also includes a frequency function.
The large and complete 4000-count LCD features comprehensive user interface symbols such as a low battery indicator. It is equipped
with a Data Hold function, which freezes the measurement. The Model 501 is compact for comfortable one-handed operation, and the hooked jaw design is easy to maneuver in crowded wiring and breaker panels. The jaw opening for the Model 501 is 1.1" (28mm).
Features:
- Compact size - fits into your pocket
- 400AAC current measurements
- 600VAC/DC volts measurements
- Resistance measurements to 400Ù
- Continuity with beeper below 40Ù
- Frequency measurements from V and A
- Hold function to "freeze" readings
- Large easy-to-read 4000-count display
- 42-segment bargraph
- Includes test leads and a soft carrying pouch
Applications
- Industrial, commercial, HVAC and residential troubleshooting
- Power panel, junction box and battery bank monitoring
- Electrical testing and troubleshooting on traditional and non-linear leads, such as adjustable
speed drives and computers
Technical Specifications
|
Model
|
501
|
|
AC Ampheres (Auto Ranging)
|
0.05 to 400A
|
|
Resolution
|
0.01 & 0.1A
|
|
Accuracy: 50 to 60 Hz
60 to 500Hz
|
1.9% Reading ±5 counts
2.5% Reading ±5 counts
|
|
AC Volts(Auto Ranging)
|
0.5 to 600V
|
|
Resolution
|
0.1 V & 1V
|
|
Accuracy: 50 to 60Hz
60 to 500Hz
|
0.8% Reading ±5 counts
1.5% Reading ±5 counts
|
|
Input Impedance
|
1 MW
|
|
DC Volts(Auto Ranging)
|
0.2 to 600V
|
|
Resolution
|
0.1V & 1V
|
|
Accuracy
|
1% Reading +/- 2 counts
|
|
Input Impedance
|
1 MW
|
|
Resistance-Ohms(W)
|
0.2 to 400 W
|
|
Accuracy
|
1% Reading +/- 2 counts
|
|
Max. Test Voltage
|
1.5 VDC
|
|
Continuity (Beeper)
|
< 40W
|
|
Max Test Voltage
|
1.5 VDC
|
|
Frequency (Hz) (Auto Ranging)
|
|
Current Input
|
4 to 10 kHz
|
|
Resolution
|
1 Hz to 10 Hz
|
|
Accuracy
|
0.1% Reading +/- 1 count
|
|
Min Input Signal
|
2 A RMS
|
|
Voltage Input
|
4 to 400 kHz
|
|
Resolution
|
1 Hz to 100 Hz
|
|
Accuracy
|
0.1 Reading +/- 1 count
|
|
Min Input Signal
|
5 V RMS
|
|
|


|
|