AEMC 6505 5000V Megohmmeter
|
|
Item Number: 6505
Manufacturer: AEMC (Chauvin Arnoux)
Part Number: 2130.18
|
AEMC 6505 5000V Megohmmeter
The AEMC 6505 Megohmmeter is a portable instrument housed in a
rugged field case and operates on either battery or line power. It performs
voltage, insulation, and capacitance measurements. This instrument
contributes to the safety of electrical installations and equipment.

The 6505's features include automatic calculation and presentation of the
Dielectric Absorption Ratio (DAR) and Polarization Index (PI). The Model 6505
displays the test voltage, insulation resistance and the leakage current during
the test. Capacitance of the sample and discharge voltage present at the test
leads is displayed at the conclusion of the test.

This Model 6505 is designed with the highest level of built-in safety features.
This meter incorporates test inhibit capabilities which will not allow test voltages
to be generated if a live sample is detected. The test terminals are recessed to
ensure operating safety.
AEMC 6505 Features:
-
Test voltage combination of 500V, 1000V, 2500V and 5000V
-
Insulation measurements from 30kΩ to 10TΩ
-
Adjustable and programmable test voltage (40 to 5100V)
-
Automatic calculation of DAR and PI values
-
Direct measurement and display of Capacitance and Leakage Current
-
Display of resistance, test voltage and run time
-
Programmable test run times and PI ratio times
-
Automatic test inhibition if live sample (>25)
-
Automatic discharge and display of discharge voltage
-
Large dual-display with time, voltage and measurements shown
-
Rugged dual wall weatherproof field case
-
Designed and built to IEC safety standards
-
EN 61010-1, 1000V CAT III
AEMC 6505 Applications:
-
Test insulation on cables, transformers, motors, generators,
insulators and wiring installations
-
High resistance or absorption tests
-
Spot reading tests
-
Timed resistance measurements
-
Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests
-
Test old or water damaged installations over long time runs
-
Motor insulation resistance measurements
|
|
AEMC 6505 Construction:
-
Connection terminals "+", "G" and "-" and access to the protective fuse
-
AC power plug (direct operation on AC and battery recharge)
-
Back-lit liquid crystal display
-
Serial Interface male plug (9-pin) for calibration only
-
Rotary selector switch with 8 positions
-
START/STOP button
-
Two function buttons
AEMC 6505 Specifications:

|
|


|
|